• 제목/요약/키워드: Treatment facility

검색결과 837건 처리시간 0.024초

시설용량을 초과하는 폐수량의 유입확률 분석을 위한 극치분포모델의 적용에 관한 연구 (A study on the application of the extreme value distribution model for analysis of probability of exceeding the facility capacity)

  • 최성현;유순유;박태욱;박규홍
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.369-379
    • /
    • 2016
  • It was confirmed that the extreme value distribution model applies to probability of exceeding more than once a day monthly the facility capacities using data of daily maximum inflow rate for 7 wastewater treatment plant. The result of applying the extreme value model, A, D, E wastewater treatment plant has a problem compared to B, C, F, G wastewater treatment plant. but all the wastewater treatment plant has a problem except C, F wastewater treatment plant based 80% of facility capacity. In conclusion, if you make a standard in statistical aspects probability exceeding more than once a day monthly can be 'exceed day is less than a few times annually' or 'probability of exceeding more than once a day monthly is less than what percent'.

해군함정의 영구자기장 감소를 위한 탈자기법 (The Magnetic Treatment Method for Low-Observable Naval Vessel)

  • 김휘석;임선호;도재원
    • 한국자기학회지
    • /
    • 제24권4호
    • /
    • pp.128-133
    • /
    • 2014
  • 강자성체로 이루어진 함정 선체의 자화에 의해 발생되는 자기장을 제어 및 최소화하는 것은 어뢰 및 기뢰로부터 함정의 생존성을 확보하기 위해 매우 중요한 일이다. 함정으로부터 발생하는 영구자기장 및 유도자기장은 각각 자기처리(탈자)와 소자의 방법으로 최소화 한다. 여러 각국의 해군들은 기뢰의 위협으로부터 함정을 안전하게 보호하기 위해 여러가지 대책들을 수립하여 엄격히 통제하고 있으며, 함정의 자기 정숙화와 관련한 독자적인 자기처리시설을 구축하여 운용하고 있다. 국내의 경우, LIG넥스원에서 신규 자기처리시설을 국내 개발하여 현재 전력화 완료 후 운용 중에 있다.

화장품 폐수처리시설의 효율제고를 위한 처리비 영향인자에 관한 연구 (A Study on Efficient Operation of Cosmetic Wastewater Treatment Facility)

  • 장명옥;조춘구
    • 대한화장품학회지
    • /
    • 제25권1호
    • /
    • pp.89-106
    • /
    • 1999
  • 폐수 처리장 관리자들로 하여금 경제적으로 효과적인 폐수처리를 위하여 화장품 제조시설을 중심으로 폐수처리공정을 파악한 후 폐수처리 및 관리에 필요한 운전인자 중 폐수 처리비 영향인자 분석을 시행하였다. 폐수처리는 대부분 활성 슬러지법을 이용하여 각업체에 적합하게 설치하여 사용하고 있으며, 폐수처리장의 일평균처리량/설계량이 0.29∼0.56으로 일평균 처리량에 비해 폐수처리장의 설계량이 큰 것으로 나타났다. 오염물질 제거율이 폐수처리비에 큰 영향을 미치고 있으며, 이를 조절하기 위한 폐수처리 운전인자는 MLSS이다. 또한, 폐수처리비를 줄이기 위한 관리 항목은 약품비와 Sludge량이며, 이를 줄이기 위해서는 SV3O의 철저한 관리가 필요하다.

  • PDF

대구시 하수처리장 운전실태에 따른 중수도 도입 방안 연구 (A Research for Introduction of Graywater Facility on Analysis of Actual Conditions of Sewage Treatment Plant in Daegu City)

  • 최미영;나욱호;홍원화;김삼열
    • 한국주거학회논문집
    • /
    • 제16권1호
    • /
    • pp.27-35
    • /
    • 2005
  • It has seen the significant increase of water consumption rate due to rapid industrialization, high-densities of city, and increasing the population; thereby leads further water resource required in near future. In order to solve this deficit there are one of solution that gray water method demonstrates advantages regarding the questions of optimal water utility and thereby master plan of water. The method of study is analysis of investigation data through interview and research of sewage treatment plants in Daegu City. Through these analysis, this paper examines the capacity of graywater and optimal graywater facility.

투수성 포장재와 비점오염저감시설의 삭감부하량 특징 비교 (Reduced Loads Characteristics Comparison Between Permeable Pavement and Non-point Pollutants Treatment Facility)

  • 길경익;전혜선
    • 한국방재학회 논문집
    • /
    • 제11권2호
    • /
    • pp.193-198
    • /
    • 2011
  • 본 연구에서는 최근 추세에 맞춰 개발사업시 장치형 및 자연형등의 인위적인 비점오염저감시설이 아닌 시설지를 투수성 포장재를 사용할 경우 얻어지는 효과를 분석하여, 설계 및 시공시 투수성 포장재 적용을 위한 기초자료를 제공하고자 한다. 그 방법으로 개발시 대상지의 면적을 불투수성과 투수성 개발로 분리 적용하여 삭감오염부하량 및 설치 공사비의 경제성을 비교 분석하였다. 그 결과 비점오염원의 처리용량 및 삭감부하량은 투수성 및 불투수성 개발에 많은 영향을 받으며, 개발시 비점오염저 감시설을 장치형이나 자연형을 단독으로 설치하기 보다는 처리대상 유역을 투수성 지역으로 개발하는 것이 배출부하량이 적은것으로 나타났다. 이를 토대로 개발시 비점오염의 관리를 위해 불투수율 면적비를 일정수준으로 제한하는 대책을 수립하면 개발에 따른 오염원의 최소화가 가능할 것으로 생각된다.

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.

슬러지탄화공정수 연계처리가 하수처리효율에 미치는 영향 (Influence of Effluent from a Sludge Carbonization Facility on Wastewater Treatability)

  • 한주은;박수형;이원태
    • 유기물자원화
    • /
    • 제27권1호
    • /
    • pp.57-64
    • /
    • 2019
  • 유입하수와 기존 연계처리수(축산폐수, 분뇨, 음폐수 등)에 더하여 슬러지탄화시설에서 발생되는 유출수가 추가로 유입되며 질소성분의 처리에 어려움을 겪고 있는 하수처리시설을 대상으로 연계처리가 처리효율에 미치는 영향을 조사하였다. 하수처리시설에 유입되는 연계처리수의 부하량(kg/d)을 산출한 결과, BOD 및 COD의 경우 음폐수와 축산폐수가 차지하는 비중이 상대적으로 크게 나타났고, T-N과 $NH_3-N$은 탄화공정수가 차지하는 비중이 가장 큰 것을 확인할 수 있었다. 탄화공정수가 방류수질에 미치는 영향을 분석하기 위하여 탄화공정수 유입 유무에 따른 공정별 처리효율을 분석결과, 호기조에서 $NH_3-N$의 질산화율이 탄화공정수가 유입되지 않는 경우 89%이었으나 탄화공정수가 유입되는 경우 55%로 낮아져 탄화공정수 유입시 질산화효율이 현저히 떨어지는 것을 확인하였다. 탄화공정수 유입으로 인한 질소 및 암모니아 부하량 증가 및 이로 인한 제거율 악화를 해결하기 위해서는 탄하공정수의 전처리를 통해 질소성분의 부하를 낮추어야 할 것으로 판단된다.

1MWth 실험연소로를 이용한 석탄의 연소특성 연구 (Study on Coal Combustion Characteristics with 1MWth Test Facility)

  • 장길홍;장인갑;정석용
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1464-1472
    • /
    • 1999
  • Design and operation of $1MW_{th}$ pulverized coal combustion testing facility are described. Also the influence of air staging on NOx emission and burnout of coal flames was investigated in this facility. The test facility consisted of coal feeding system, firing system and flue gas treatment system. A top-fired externally air staging burner was adopted in order to avoid influence of gravity on the coal particles and for easy maintenance. Distribution of temperature and chemical species concentration of coal flames could be measured in vertical pass of furnace. Main fuel was pulverized (83.4% less than $80{\mu}m$) Australian high bituminous coal. From variety of test conditions, overall excess air ratio was selected at 1.2(20% excess air). Tho study showed that increasing the staged air resulted in lower NOx omission, and it was suggested to be more than 40% of the total combustion air for the substantial NOx reduction. Sufficient burnout was not achievable when NOx emission was less than 500ppm. Also, the amount of core air did not influence tho NOx reduction.

액체로켓 추진기관의 후류처리장치 고찰 (Investigation of Exhaust Facility of Liquid Rocket Propulsion System)

  • 조남경;이광진;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.133-138
    • /
    • 2012
  • 후류처리 장치는 기본적으로 화염유도로의 역할을 하며 추가적인 기능에 따라 소음/배기가스 처리 장치, 고공 모사 장치 등으로 분류될 수 있다. 본 연구에서는 화염 및 충격파로 부터의 발사체 보호, 제트펌프, 유해배기 가스 저감 등 후류처리 장치에 적용되는 원리를 제시하였다. 물 분사에 의한 소음감소는 마하파를 약화시키며 물의 증발 및 응축을 통해 제트의 에너지를 줄이는 원리를 이용함을 보였다. 또한 후류처리 장치에 적용되는 원리의 고찰을 통하여 수직형 후류처리 장치의 개념을 제시하였다.

  • PDF

Radiological safety analysis of a newly designed spent resin mixture treatment facility during normal and abnormal operational scenarios for the safety of radiation workers

  • Jaehoon Byun;Seungbin Yoon;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1935-1945
    • /
    • 2023
  • The radiological safety of workers in a newly developed microwave-based spent resin treatment facility was assessed based on work location and operational scenarios. The results show that the remote-operation room worker was exposed to maximum annual dose of 3.19E+00 mSv, which is 15.9% of the dose limit, thereby confirming radiological safety. Inside the pathway, annual doses in the range of 7.87E-02-2.07E-01 mSv were measured initially at the mock-up tank and later at the point between the spent resin separation and treatment parts. The dose of emergency maintenance workers was below the dose limit (4.08E-03-4.99E+00 mSv); however, before treatment (separation and microwave), the dose of maintenance and repair workers exceeded the dose limit. The doses of the effluent removal workers at the zeolite and activated carbon storage tank and spent resin storage tank were the lowest at 2.79E-01-2.87E-01 mSv and 9.27E-01 mSv in "1 h" and "4-5 h of operation", respectively. The immediately lower and upper layers of the facility room exhibited the highest annual doses of 1.84E+00 and 3.22E+00 mSv, respectively. Through this study, a scenario that can minimize the dose considering the movement of spent resin through the facility can be developed.