Purpose: We performed three-dimensional (3D) dose reconstruction-based pretreatment verification to evaluate gamma analysis acceptance criteria in volumetric modulated arc therapy (VMAT) for prostate cancer. Materials and Methods: Pretreatment verification for 28 VMAT plans for prostate cancer was performed using the COMPASS system with a dolphin detector. The 3D reconstructed dose distribution of the treatment planning system calculation (TC) was compared with that of COMPASS independent calculation (CC) and COMPASS reconstruction from the dolphin detector measurement (CR). Gamma results (gamma failure rate and average gamma value [GFR and γAvg]) and dose-volume histogram (DVH) deviations, 98%, 2% and mean dose-volume difference (DD98%, DD2% and DDmean), were evaluated. Gamma analyses were performed with two acceptance criteria, 2%/2 mm and 3%/3 mm. Results: The GFR in 2%/2 mm criteria were less than 8%, and those in 3%/3 mm criteria were less than 1% for all structures in comparisons between TC, CC, and CR. In the comparison between TC and CR, GFR and γAvg in 2%/2 mm criteria were significantly higher than those in 3%/3 mm criteria. The DVH deviations were within 2%, except for DDmean (%) for rectum and bladder. Conclusions: The 3%/3 mm criteria were not strict enough to identify any discrepancies between planned and measured doses, and DVH deviations were less than 2% in most parameters. Therefore, gamma criteria of 2%/2 mm and DVH related parameters could be a useful tool for pretreatment verification for VMAT in prostate cancer.
암은 한국인의 사망원인 중 1위이며, 간암은 위암, 폐암과 함께 한국인의 3대 암의 하나로 발생 빈도가 높은 암이나, 대부분의 환자가 자각증상이 없어 수술이 가능한 시기를 지난 후에 진단되어 다양한 치료에도 불구하고 생존율이 낮다. 간암은 진단 시 종양의 크기가 비교적 크며, 주위 정상 간 조직의 견딤선량이 낮아 통상적인 방사선치료로는 간암세포의 치사량을 조사할 수 없어 표적장기에는 다량의 방사선을 조사하면서 주위정상조직에는 조사량을 최소로 할 수 있는 세기조절 방사선치료의 필요성은 매우 크다. 그러나 간암이나 폐암에서는 호흡이나 심박동, 장의 연동운동 등으로 상, 하, 좌, 우, 전, 후 방향으로 종양이 움직임으로 계획된 치료선량이 정확한 부위에 전달되는지에 대한 QA 기법이 개발되어 있지 않아 세기조절 방사선치료의 이론적인 많은 이점에도 불구하고 실제 임상에서의 치료는 활발하지 못하다. 본 연구에서는 35예의 간암환자를 대상으로 하여 복잡한 술기가 필요하지 않아 환자가 불편하지 않고 환자의 치료시간도 지연시키지 않으면서, 임상적용이 용이한 QA 방법을 고안하여 간암환자의 임상적용가능성을 입증하고자 하였다. 모든 환자에서 호흡으로 인한 종양의 이동폭이 가장 크다고 보고되고 있는 상하의 margin은 횡격막의 상하 이동을 5회 측정하여 평균값으로 정하고, 이 평균값만큼 상하 자동으로 반복 이동하도록 특수 제작한 장치 위에 팬텀을 고정하여 환자에서와 같은 조건으로 방사선을 조사한 후 방사선조사 선량을 TLD와 전리함으로 측정하고 컴퓨터 계산치와도 비교하여 3% 이내의 오차를 확인하였다. 환자의 첫 번째 치료에서 만든 확인 필름과 인체모형 팬텀에서 같은 방법으로 방사선을 조사하여 만든 확인 필름을 필름 스캐너로 선량을 측정한 후 90% 등선량 곡선을 비교하여도 큰 차이를 발견할 수 없어 임상에서 적용 가능한 QA 기법으로 제안하고자 한다.
The purpose of this study is to evaluate the clinical risk of spinal radiosurgery by calculating the dose difference due to dose calculation algorithm and multi-leaf collimator positioning error. The images acquired by the CT simulator were recalculated by correcting the multi-leaf collimator position in the dose verification program created using MATLAB and applying stoichiometric calibration and Monte Carlo algorithm. With multi-leaf collimator positioning error, the clinical target volume (CTV) showed a dose difference of up to 13% in the dose delivered to the 95% volume, while the gross tumor volume (GTV) showed a dose difference of 9%. The average dose delivered to the total volume showed dose variation from -8.9% to 9% and -10.1% to 10.2% for GTV and CTV, respectively. The maximum dose delivered to the total volume of the spinal cord showed a dose difference from -14.2% to 19.6%, and the dose delivered to the 0.35 ㎤ volume showed a dose difference from -15.5% to 19.4%. In future research, automating the linkage between treatment planning systems and dose verification programs would be useful for spinal radiosurgery.
최근 토모테라피의 빗면 조사 빔(tangential beam)을 이용하여 전자 빔과 광자 빔의 인접 조사 없이도 치료에 필요한 선량을 균일하게 전달할 수 있다는 결과가 보고되면서, 토모테라피를 이용한 피부암 치료가 증가하고 있다. 그러나 토모테라피 치료 빔은 선형가속기 빔과는 다른 물리적인 특성을 갖고 있으며, 여러 가지 동적 요소들이 결합되어 빔을 조사하므로 기존에 사용하고 있는 팬톰 이외의 독립적인 도구를 사용하여 피부 선량을 검증할 필요가 있다. 피부 선량 검증을 위하여 영상 기반 치료용 팬톰에 선량 측정 기능을 추가한 새로운 팬톰을 개발하였으며, 열형광선량계(LiF, TLD-100)와 GafChromic EBT필름을 팬톰에 삽입하여 전달된 피부 선량을 측정하였다. 팬톰의 반지름 방향으로 피부 영역을 포함하여 깊이 35 mm 영역까지 균일한 선량을 전달했을 때, 필름으로 측정한 특정 점에서의 선량은 계산 선량에 대하여 평균 약 2% 정도 낮게 나타났으며 처방 선량보다 최대 ${\pm}14%$까지 더 높거나 낮은 선량이 전달된 영역이 나타나는 것을 확인 할 수 있었다. 치료 계획 시스템의 계산 결과와 비교하였을 때, 조사 영역에서 측정한 선량 분포의 균일성이 감소하였으며 팬톰 내에 삽입한 테플론에 의한 선량 변화는 거의 나타나지 않았다. 토모테라피의 치료 빔을 이용하여 피부암과 같이 굴곡이 있는 낮은 깊이에 위치한 표적에 선량을 전달하는 경우, 연속적으로 회전하며 조사되는 빗면 조사 빔의 특성과 치료 계획 시스템의 선량 계산 방식에 따라서 피부 선량의 오차가 허용 범위보다 더 크게 나타날 수 있으므로 치료전 측정을 통한 피부 선량 검증이 필요하다.
방사선치료에서는 환자 체내에 전달된 선량이 원래 의도한 데로 분포되는 지 확인하기 위하여 균질한 팬텀을 이용한 정도 관리를 치료 전에 주로 시행하고 있다. 하지만 균질한 팬텀을 이용한 정도 관리는 표면이 불규칙적이고 불균질한 인체에 대한 선량분포를 완전히 보증해 주지는 못하고 있다. 본 연구에서는 환자를 투과하는 선량의 분포를 측정하여 역으로 환자체내 선량 분포를 계산하는 투과선량 기반 체내선량 검증프로그램을 개발하였다. 투과선량은 주방사선과 산란방사선으로 이루어져 있는데, 본 연구에서는 전자포탈영상장치로 측정한 선량분포로부터 주방사선만을 이용한 간단한 식으로 환자체내선량분포를 계산하는 프로그램과 감마값 분포를 평가하여 두 선량분포를 서로 비교할 수 있는 프로그램을 개발하였다. 개발된 프로그램을 이용하여 계산한 팬텀의 등중심점을 지나는 관상면의 체내선량 분포는 치료계획시스템에서 제공하는 동일 평면의 선량분포와의 비교결과 균질팬텀에서 평균 95%, 비균질팬텀에서 81.8%의 감마통과율을 보였다.
Kim, Kwon Hee;Back, Tae Seong;Chung, Eun Ji;Suh, Tae Suk;Sung, Wonmo
한국의학물리학회지:의학물리
/
제32권4호
/
pp.116-121
/
2021
Purpose: To investigate the effects of dose rate on intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We performed gamma tests using portal dose image prediction and log files of a multileaf collimator. Thirty treatment plans were randomly selected for the IMRT QA plan, and three verification plans for each treatment plan were generated with different dose rates (200, 400, and 600 monitor units [MU]/min). These verification plans were delivered to an electronic portal imager attached to a Varian medical linear accelerator, which recorded and compared with the planned dose. Root-mean-square (RMS) error values of the log files were also compared. Results: With an increase in dose rate, the 2%/2-mm gamma passing rate decreased from 90.9% to 85.5%, indicating that a higher dose rate was associated with lower radiation delivery accuracy. Accordingly, the average RMS error value increased from 0.0170 to 0.0381 cm as dose rate increased. In contrast, the radiation delivery time reduced from 3.83 to 1.49 minutes as the dose rate increased from 200 to 600 MU/min. Conclusions: Our results indicated that radiation delivery accuracy was lower at higher dose rates; however, the accuracy was still clinically acceptable at dose rates of up to 600 MU/min.
In-vivo dosimetry is an essential tool of quality assurance programs in radiotherapy. The most commonly used techniques to verify dose are thermoluminescence dosimeter (TLD) and diode detectors. Metal oxide semiconductor field-effect transistor (MOSFET) has been recently proposed for using in radiation therapy with many advantages. The reproducibility, linearity, isotropy, dose rate dependence of the MOSFET dosimeter were studied and its availability was verified. Consequently the results can be used to improve therapeutic planning procedure and minimize treatment errors in radiotherapy.
Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
한국의학물리학회지:의학물리
/
제29권2호
/
pp.53-58
/
2018
This paper evaluates patient-specific quality assurance (PSQA) in the treatment of small and multiple tumors by the CyberKnife system with fixed collimators, using an ion chamber and EBT3 films. We selected 49 patients with single or multiple brain tumors, and the treatment plans include one to four targets with total volumes ranging from 0.12 cc to 3.74 cc. All PSQA deliveries were performed with a stereotactic dose verification phantom. The A16 microchamber (Standard Imaging, WI, USA) and Gafchromic EBT3 film (Ashland ISP Advanced Materials, NJ, USA) were inserted into the phantom to measure the point dose of the target and the dose distribution, respectively. The film was scanned 1 hr after irradiation by a film digitizer scanner and analyzed using RIT software (Radiological Imaging Technology, CO, USA). The acceptance criteria was <5% for the point dose measurement and >90% gamma passing rate using 3%/3 mm and relative dose difference, respectively. The point dose errors between the calculated and measured dose by the ion chamber were in the range of -17.5% to 8.03%. The mean point dose differences for 5 mm, 7.5 mm, and 10 mm fixed cone size was -11.1%, -4.1%, and -1.5%, respectively. The mean gamma passing rates for all cases was 96.1%. Although the maximum dose distribution of multiple targets was not shown in the film, gamma distribution showed that dose verification for multiple tumors can be performed. The use of the microchamber and EBT3 film made it possible to verify the dosimetric and mechanical accuracy of small and multiple targets. In particular, the correction factors should be applied to small fixed collimators less than 10 mm.
The goal of radiation treatment planning is to deliver the dose to the patient within $5\%$ of that prescribed. We have often encountered the situation that the area which have not only several irregular contours but also tissue heterogeneities should be treated. With conventional devices such as wedges, missing tissue compensator. there are some limitations to achieve the uniform dose distribution in treatment volume. The use of CT simulator, 3-D planning system, computer-controlled milling machine enables it to deliver the dose uniformally. This report includes the whole procedure which have patient data acquisition 3D planning, computer-controlled milling, performance verification of 3D compensator, and TLD evaluation. We applied it for the treatment of head and heck cancer only. In Spite of the irregular contour and different electron density of tessue, we have achieved the uniformity of the dose distribution within ${\pm}3\%$ relatively. Although there are some problems which are not only verification of performance but uncertainties of using the new treatment device, we believe that the improvement of dosimetry will eliminate the uncertainties of that application. so the other lesions besides head and neck can will be ale to use the 3D compensator to achieve the dose uniformity
이 연구의 목적은 6 MV X선 빔의 미로 도어 설계 시 미로 도어 바깥 측정지점에서 계산되는 성분별 선량률의 정확성을 검증하는 식을 유도하는데 있다. NCRP 보고서 151과 IAEA 안전 보고서 시리즈 47에 기술된 미로 도어 바깥 측정지점에 대한 성분별 선량률 계산식 기반으로, 도면 기반 파라미터들의 값 적용시 성분별 선량률 계산식 및 보수적 파라미터들의 값 적용 시 성분별 선량률 계산식을 유도하였다. 각각의 성분에 대한 두 개의 선량률 계산식들로부터, 미로 도어 바깥 측정지점에서 성분별 선량률 검증식은 유도되었다. 결과로서 얻어진 미로 도어 바깥 측정지점에서 성분별 선량률 검증식은 설계자가 계산한 미로 도어 바깥 측정지점에서 성분별 선량률이 유도된 성분별 선량률 검증식에서 얻어진 선량률 범위 안에 포함되는지 비교분석할 수 있다. 이 검증식은 설계자가 계산한 성분별 선량률의 정확성을 검증하는데 실무적으로 유용하게 사용될 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.