• Title/Summary/Keyword: Treatment Process

Search Result 10,133, Processing Time 0.036 seconds

Dehydration and RDF Production of Organic Sludge with Hydrothermal Pre-treatment Process (증기열 전처리공정을 이용한 유기성 슬러지의 건조 및 성형연료화)

  • Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.526-531
    • /
    • 2009
  • This paper suggests the dehydration and RDF(Refuse Derived Fuel) production of organic sludge, livestock manure and sewerage sludge causing environmental problems, with hydrothermal pre-treatment process. The renewable technology from the organic wastes must involve short treatment time required, reusable energy source, anti-odor and viruses, low cost for the treatment, and well-fertilization. The hydrothermal pre-treatment process promotes to evaporate moisture in the sludge after being shortly treated in a reactor, which is supplied steam and heat by an external boiler, due to the pressure with steam breaks the cell walls of the sludge, so this process removes the internal moisture of the cell. Then, the treated sludge(solid-state) is mixed with waste vinyls called RDF(6,706kcal/kg).

Effect of Flow Rate on the Continuous Cycling Electrolytic Treatment Process for Silver Ion Containing Wastewater (은 함유 폐수의 연속 순환 전해처리 시 유량변화가 회수 공정에 미치는 영향)

  • Chung, Won-Ju;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.577-580
    • /
    • 2007
  • The influence of flow rate has been investigated on the treatment efficiency of continuous cycling electrolytic process employing artificial and actual photographic wastewater which containing silver ion. For artificial wastewater, the treatment efficiency of process was found to rise ca. three times when the flow rate of wastewater was increased from 3 mL/min to 15 mL/min. The process efficiency was doubled under the same condition regarding actual wastewater. The effect of flow rate on the treatment efficiency was observed to be altered according to the metal ionic form and solution composition. The coefficient of mass transfer was estimated using model equation, which verified that the raised treatment efficiency at higher flow rate was due to the increased mobility of ionic species.

Development of the Diode Laser Heat Treatment Robot System Based on OLP Simulator (OLP 시뮬레이터 기반의 다이오드 레이저 열처리 로봇시스템 개발)

  • Park, Kee-Jin;Yoon, Sung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.8-14
    • /
    • 2015
  • Heat treatment for car body molds is mainly a manual process performed by a worker. The performance of this process is affected by workers' skill level, and has limitation in maintaining uniform product quality. In this study, we developed a diode laser heat treatment robot system that implements an OLP type simulator to overcome the limitation of manual process, and to improve and stabilize the quality level. In addition, we verified the efficiency of the robot system and mechanism stability from the early stage through design verification and simulated analysis in the development stage. In addition, we carried out a field test to study the way to establish optimized D/B for diode laser heat treatment criteria for car body molds, such as heat treatment speed, interval, etc. via site experiment.

Development of An Eco-friendly Surface Treatment Process for the Design of the Al Lead Tab in Lithium-ion Batteries

  • Cheon, Jeongsuk;Kim, Jongwon
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.3
    • /
    • pp.153-158
    • /
    • 2020
  • With the recent popularity of mobile devices, the demand for lithium-ion batteries is increasing. In this study, the surface treatment process for the development of the Al (aluminum) lead tab for positive electrode, a key component of the pouch-type lithium-ion battery, was investigated. Anodizing and sealing processes were tested as surface treatment techniques. It was found that only a sealing process is needed to obtain sufficient adhesive strength. In the present study, an adhesive strength of 17 N/12 mm was achieved by degreasing and etching pretreatment, followed by a sealing process of 10 min duration. This adhesive strength was greater than that achievable using Cr (chromium) surface treatment. Using various surface analysis techniques, the shape and composition of the surface before and after being subjected to the surface treatment were compared and analyzed. The results of this study are expected to contribute to the development of an eco-friendly lead tab.

A Study on the applications of flow control methods in sewage treatment process system (하수처리 공정시스템에서 유량제어기법의 활용에 관한 연구)

  • Jeong, Seong-Yun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.597-604
    • /
    • 2016
  • This study was begun with the object of actively reflection the rapid technological advancements of the electronical control and mechanical control industries to sewage disposal methods. Or focuses on applying a flow control method that utilizes inverters and automatic valves to sewage treatment process systems. This study proposes that sewage treatment process systems architects must acquire a certain degree of technical skills in the areas of electrical and mechanical controls in order to raise the standard of completeness of sewage treatment process systems. And further emphasizes that there is required continuous research on automatics valves that are used in sewage treatment.

Analysis of sewage treatment process for the improvement of T-N removal process (T-N 제거공정 개선을 위한 하수처리장 공정 분석)

  • Shin, Choon Hwan
    • Journal of Environmental Science International
    • /
    • v.27 no.2
    • /
    • pp.99-107
    • /
    • 2018
  • In order to design the improvement process for T-N removal, the treatment process of Suyoung, Gangbyeon, and Noxan sewage treatment plants (STP) in Busan was anlayzed. Suyoung STP shows a T-N removal efficiency of about 69.8% with MLE(Modified Ludzack ettinger) and A2O+MBR. However, it is necessary to improve the process to maintain over DO of 1 mg/L and is required to install a flow control tank to minimize the rainfall effect. Gangbyun STP shows a about 70.2% T-N removal efficiency with A2O+GFF(gravity fiber filtration). However, in order to improve T-N removal efficiency, it is needed to install MLE process to treat recycle water. Noksan STP shows a T-N removal efficiency of about 71.0% with MLE+Chemical treatment and shows stable T-N concentration in effluent. However, it is required a toxic chemical management process because bad wastewater flows into the STP, also is necessary a process improvement in order to increase internal recycling ratio. Especially, it is required a process improvement to increase HRT of nitrification tank because Suyoung and Gangbyeon STPs shows low nitrification efficiency during winter season.

Analysis of RCSTP Treatment Efficiency using BCS-II Process: Case Study of An-dong City (BCS-II 공법을 이용한 마을하수도 처리 효율 분석: 안동시를 대상으로)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.423-431
    • /
    • 2014
  • Supply of rural community sewage treatment plant (RCSTP) is need for protect of water quality like water source and development of agriculture areas. In this study conducted analysis on characteristics of RCSTP sewage and treatment efficiency of installed treatment process using operation results of RCSTP in an-dong area. high organic matter and nutrient were contained in RCSTP sewage of an-dong than urban area. RCSTP treatment process in an-dong was shown stable treatment efficiency. But nutrient treatment efficiency was shown more sensitive result about SRT and F/M ratio than organic matter treatment efficiency. And RCSTP treatment process in an-dong was shown higher treatment efficiency than other treatment proces like $A^2/O$, SBR and media. Thus, this process is effective treatment process for application of RCSTP.

The Development of Industry Operation Control System using Intelligent Web Monitoring for the Heat Treatment Process (열처리공정의 지능형 웹 모니터링 산업용 공정제어 시스템 개발)

  • Oh, J.H.;Bae, H.J.;Choi, G.S.;Ahn, D.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.181-186
    • /
    • 2005
  • Because of advanced control technology, Shop floor control system of various kinds of equipment and machinery need a web based remote monitoring to control process efficiently. This paper presents the development of Operation Control System. Operation Control System(OCS) is based on intelligent web monitoring, so that OCS is improved the working condition for the line of heat treatment process and the product's quality. The developed OCS is consisted of Atmega128(MCU) based on embedded system, running the data logging of the line of heat treatment process. Web monitoring system is based on CS8900 ethernet controller and TCP/IP for remote monitoring responsibility between a server and clients and controlling the progress of entire system. The developed OCS is implemented on the line of heat treatment process and shows the improvement of environment condition, product's quality and efficiency of process line.

  • PDF

Astudy on Treatment of Livestock Wastewater using Coagulation and Fenton Oxidation Process (응집 및 fenton 산화공정을 연계한 축산폐수처리에 관한 연구)

  • Cho, Chang-Woo;Ryou, Jae-Woong;Chung, Paul-Gene
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.610-614
    • /
    • 2004
  • The objective of this study was to remove organics and color in livestock wastewater using coagulation and Fenton oxidation process. After coagulation process as $1^{st}$ treatment, organics in $1^{st}$ treatment water were removed by using OH radical produced in Fenton oxidation process. Removal efficiencies of $COD_{Mn}$ and color were 87.2% and 95.7% separately. At that time, the ratio of $Fe^{2+}/H_2O_2$ was 0.8~1.0, and range of reaction pH was effective at the pH of 3.5~3.8. The Reaction time of 120min more than 60min or 90min was sufficient in Fenton process. Removal efficiency of organics was higher two- or multi-stage treatment than one-stage treatment.

Diagnostic Software for Wastewater Treatment Plant using Activated-Sludge Process (활성슬러지 폐수처리장 진단 소프트웨어)

  • 손건태;이재은
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.611-616
    • /
    • 1999
  • The diagnostic software for the wastewater treatment plant using activated-sluge process is developed in order to increase the efficiency of management of the wastewater treatment plant. This software is based on the expert system and the visualized user interface, including the diagnosis of quantitative and qualitative data. For the generalization of this software, the initialization of each unit process and updating the files can be possible.

  • PDF