• Title/Summary/Keyword: Trap level

Search Result 217, Processing Time 0.032 seconds

Pregnancy Outcomes in Relation to Plasma TRAP Concentration of Maternal and Umbilical Cord (임신말 모체와 제대혈의 혈장 총유리기포집 항산화능과 임신결과)

  • Ahn Hong Seok
    • Journal of Nutrition and Health
    • /
    • v.37 no.9
    • /
    • pp.817-824
    • /
    • 2004
  • The purpose of this study was to analyze the intake of antioxidant vitamins and plasma TRAP concentrations of 60 maternal-infant pairs (30 in normal term delivery group, NT; 30 in preform group, PT) We also investigated the relationship between plasma TRAP levels of maternal-umbilical cord blood and pregnancy outcomes. Mean energy intakes of NT and PT pregnant women were 93.2% and 85.4% and their protein intakes were 113.3% and 110.9% of the recommended dietary allowance (RDA), respectively. The vitamin A intakes of NT and W pregnant women were 559.7 RE and 497.8 RE, which were less than RDA. While the vitamin E and C intakes of both NT and PT pregnant women were more than RDA. The maternal plasma TRAP level of PT was 1.41 mmol/l and that of was 1.50 mmol/l, which was significantly higher than TRAP level of PT (p < 0.05) . The umblical cord plasma TRAP levels of NT and PT were 1.44 mmol/l and 1.23 mmol/l, which indicates the significant difference between those two groups (p < 0.001) . In case of comparing the TRAP level of maternal and umbilical cord blood, there was no significant difference in NT pregnant women, however, in PT group maternal the TRAP level significant higher than that of umbilical cord (p < 0.001). The length of gestation and plasma TRAP level of maternal and umbilical cord showed a positive correlation. However, other parameters of pregnancy outcomes such as birth weight, weight gain, and Apgar score were not affected by the plasma TRAP levels. Based on these results, preform infants could have a risk of oxidative stress because of low plasma TRAP level.

The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter (트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석)

  • Kim, Soo-Hong;Kim, Yoon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

Effect of Life Style and Dietary Factors on Plasma Total Radical-Trapping Antioxidant Potential (TRAP) in Korea Adult (생활양식과 식이성 요인이 성인의 혈장 총 유리기포집 항산화능(TRAP) 수준에 미치는 영향)

  • 송미영;김정신;박은주;강명희
    • Journal of Nutrition and Health
    • /
    • v.34 no.7
    • /
    • pp.762-769
    • /
    • 2001
  • Recently developed TRAP assay(Total Radical-trapping Antioxidant Potential) is a new technique which enable effectively the measurement of total antioxidant status in the plasma. Researches using TRAP method have rarely been reported in Korea. Therefore, we investigated effects of various life-style and dietary factors on plasma TRAP level in Korean adult population. The subjects consisted of 161 health adult male(n=105) and female (n=56) aged 19-57. A self-administered questionnaire ascertained life-style factors including smoking habits, alcohol use, physical activity. Dietary factors were analyzed by 24 hour recall method. TRAP was determined spectrophotometrically in plasma at 734nm. Mean plasma TRAP concentrations were slightly higher in males (1.35$\pm$0.02mM) and females(1.30$\pm$0.02mM) without significance. There were significant correlations between plasma TRAP levels and life-style factors including exercise and smoking Plasma TRAP levels were affected more by exercise than by smoking. Moderate amount exerciser(exercise time $\geq$30min/day) had significantly higher level of plasma TRAP levels in male smokers(1.33$\pm$0.03mM) were significantly lower than those in male nonsmokers(1.39$\pm$0.01mM, p<0.05), but the difference was not seen in female subjects. Intakes of vitamin C(r=0.288, p=0.007) or folate (r=0.258, p=0.016) were positively correlated with plasma TRAP levels in nonsmokers, but those relations were not seen in smokers. Dietary factors such as vegetables (r=0.288, p=0.007)or folate (r=0.258, p=0.016) were positively correlated with plasma TRAP levels in nonsmokers, but those relations were not seen in smokers. Dietary factors such as vegetables (r=0.277, p=0.009) and legumes(r=0.263, p=0.013) consumption were positively related to plasma TRAP concentrations also in nonsmokers only. Regular green tea drinkers showed significantly greater level of plasma TRAP than the non green tea drinkers(1.36$\pm$0.01mM vs 1.30$\pm$0.03mM, p<0.05). These results suggest that the regular exercise($\geq$30min daily), nonsmoking, and consumption of vegetables, legumes and green tea would contribute to improving plasma TRAP levels in Korean adults.

  • PDF

The Study of Deep Level Behaviors in Si Contaminated by Iron (Fe 오염에 따른 Si내의 deep level거동에 관한 연구)

  • Mun, Yeong-Hui;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • v.9 no.1
    • /
    • pp.104-107
    • /
    • 1999
  • We investigated the effects of cooling condition on deep levels and iron precipitate formation in iron-contaminated p-type silicon by DLTS(Deep Level Transient Spectroscopy) and preferential etching technique. Dependency of cooling condition on Bulk Micro-Defect (BMD) and four different iron-related deep traps were observed. For normal cooling condition, T1, T2, T3, T4 traps that related to Fe\ulcorner or Fe-O complex were obtained. However, the trap with activation energy, 0.4 eV was observed for slow cooling condition. The trap caused by the $\textrm{Fe}^{+}\textrm{}^{-}$ pair (H4:0.56eV) were detected only at the case of $\textrm{LN}_{2}$ quenching condition.

  • PDF

Analysis of SOHOS Flash Memory with 3-level Charge Pumping Method

  • Yang, Seung-Dong;Kim, Seong-Hyeon;Yun, Ho-Jin;Jeong, Kwang-Seok;Kim, Yu-Mi;Kim, Jin-Seop;Ko, Young-Uk;An, Jin-Un;Lee, Hi-Deok;Lee, Ga-Won
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.34-39
    • /
    • 2014
  • This paper discusses the 3-level charge pumping (CP) method in planar-type Silicon-Oxide-High-k-Oxide-Silicon (SOHOS) and Silicon-Oxide-Nitride-Oxide-Silicon (SONOS) devices to find out the reason of the degradation of data retention properties. In the CP technique, pulses are applied to the gate of the MOSFET which alternately fill the traps with electrons and holes, thereby causing a recombination current Icp to flow in the substrate. The 3-level charge pumping method may be used to determine not only interface trap densities but also capture cross sections as a function of trap energy. By applying this method, SOHOS device found to have a higher interface trap density than SONOS device. Therefore, degradation of data retention characteristics is attributed to the many interface trap sites.

Trap Level Study of Alq3 for OLED with Debye Dielectric Relaxation (Debye 이론을 이용한 유기 EL용 Alq3계 재료의 Trap Level 측정)

  • Jeong, Yong-Seok;Jeong, Yeon-Tae;Kim, Jong-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.668-672
    • /
    • 2004
  • Upon Debye's dielectric relaxation theory, we tried simple determination method of trap level in organic EL materials. From dielectric measurements in the 20 Hz - 1 MHz frequency range and in the 150 K - 320K temperature range, the depth of traps in Alq$_3$ filled with remaining electrons was determinated. Comparing to other determination techniques like TSL, or TL, the apparatus all we need is just simple LCR meter, thermometer and cooling method(liquid nitrogen). The mean activation energy is about 0.20 eV. It is in good agreement with previous determinations by other techniques like TSL. This results consolidate the validity of Burrow's transport mechanism model. Further intensified experiment with UV light on the dielectric absorption(Photodipolair effect) was nevertheless disturbed by the photoconductivity component.

A Study on Filter Efficiency Analysis and Harmonic Reduction of Single Phase NPC Multi-Level Inverter with LC-Trap Filter (LC트랩필터를 갖는 단상 NPC 멀티레벨 인버터의 출력 고조파 저감 및 필터 효율 분석에 관한 연구)

  • Kim Soo-Hong;Seo Kang-Moon;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.430-435
    • /
    • 2006
  • This paper presents a method about the efficiency analysis and the harmonic reduction of single phase NPC multi-level inverter with LC-trap filter and LCR output filter. The proposed LC-trap filter is comprised of a conventional LC output filter, by using LC-trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also, low damping resistor is increased the efficiency of the output filter. Experimental verification of the proposed circuit is provided with single phase NPC multilevel inverter system and DSP controller.

The Effects of Exercise and Other Relating Factors on the Activity of Erythrocyte Antioxidant Enzymes and Plasma TRAP Levies in Male College Students (남자 대학생의 적혈구 항산화 효소 활성 및 혈장 TRAP수준에 대한 운동량 및 기타 관련 요인의 영향)

  • 강명희;윤지숙
    • Journal of Nutrition and Health
    • /
    • v.35 no.1
    • /
    • pp.30-36
    • /
    • 2002
  • This study was conducted to evaluate the effect of regular exercise and other relating factors on the activities of erythrocyte antioxidant enzymes and plasma total radical-trapping antioxidant potential (TRAP) in 61 healthy male college students. The study population were divided in two groups ; small amount of exerciser (exorcise time less than 30min/d) and moderate amount of exerciser (exorcise time more than 30min/d) according to their physical exercise habits measured by a questionnaire. Dietary intake of vitamin C and vitamin E, Plasma lipid Profiles, erythrocyte superoxide dismutase(SOD), glutathione peroxidase(GSH-Px) and catalase activities, as well as plasma TRAP levels were determined. Plasma TRAP level was significantly higher in moderate amount of exercisers than that in small amount of exercisers. No significant differences were observed in erythrocryte SOD, catalase and GSH-Px between the two groups. Mean exercise time was positively correlated with the plasma level of TRAP significantly, and amount of alcohol consumption was negatively correlated with the erythrocyte SOD activity, Dietary vitamin C and I intakes did not correlated with either erythrocyte enzyme activities or plasma TRAP levels. There were positive correlations between plasma HDL-cholesterol, and erythrocyte GSH-Px or plasma TRAP levels. Plasma vitamin C concentrations was negatively correlated with plasma TRAP levels and erythrocyte SOD activity, however plasma vitamin C concentration was positively correlated with erythrocyte GSH-Px activity, The results would suggest that regular moderate exercise, nonsmoking, high HDL-cholesterol and high plasma vitamin E concentration enhance antioxidant defences against reactive oxygen species and may increase the likelihood of a healthier life span.

Some Toxic Heavy Metals Transferring Rates to Decoction of Five Most Generally Adopting Herbal Medicinal Prescriptions (다섯 가지 다용한약처방의 전탕 전후 유해 중금속 이행률 조사)

  • Kim, Kee Dong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.19 no.3
    • /
    • pp.103-113
    • /
    • 2015
  • Objective : Five most generally adopting basic oriental prescriptions (yookmijihwangtang, ojeoksan, sipjeondaebotang, samultang, bojoongikgitang) samples were collected from 10 oriental hospitals nationwide and the transferring ratio to aqueous phase (TRAP) were calculated. Method : The samples are grounded evenly and the decocted at $120^{\circ}C$ for 12 min on hot plate and then filtered. The concentrations of As, Cd, Co, Cr and Pb in before and after decoction were measure by ICP/MS and the TRAPs were calculated. Results : The concentrations of As, Cr and Pb in the ground samples before decoction were all below criteria level, and TRAP values were also very low (<10%). For Cd, although some ground samples before decoction showed relatively high concentration level compare to the criteria level, because of their low TRAP (~3%), the actual concentrations in the decoction were quite low compare the criteria level. The Co's concentrations in the ground samples before decoction were all relatively low level. However, the TRAP of Co was astonishingly high value of around 40% average. Conclusion : The toxic heavy metal concentrations in the decoction were very low compare to the criteria level. The TRAPs are less than <10% except Co. The toxic heavy metals in the prescriptions are mainly remained in the residue and the only very small fraction may transferred to the decoctions. Therefore the toxicity of the oriental herbal medicine about the toxic heavy metal may be overstressed. The Co's TRAP turned out to be quite high value (40% average). Since the criteria level wes not established yet, the safety of decoctions according to Co was not fully confirmed.

A study on the analysis of carrier properties and trap energy depth in the low-density polythylene electrets (저밀도 폴리에틸렌 일렉트렉트에 있어서 케리어의 성질과 Trap 깊이 해석에 대한 연구)

  • 이준웅
    • 전기의세계
    • /
    • v.29 no.8
    • /
    • pp.511-518
    • /
    • 1980
  • The thermostimulated discharge currents of low-density polyethylene electrets were measured versus the principal experimental variables. Several electrode types were used for the charging and discharging procedures. The results led to know the experimental conditions for the heterocharge and homocharge accumulating and decreasing. The electronic structure parameters of polyethylene such as trap level, density of traps, hopping length, mobility, trap time constants were deduced. A method for evaluating the local electric field inside the electret is proposed.

  • PDF