• 제목/요약/키워드: Transverse steel ratio

검색결과 191건 처리시간 0.04초

스테인리스 강 클리드 알루미늄 판재의 일축인장시 변형거동 (EEFORMATION BEHAVIOR OF STAINLESS STEEL-CLAD ALUMINUM SHEET METALS UNDER UNIAXIAL TENSION)

  • 최시훈;김근환;오규환;이동녕
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1995년도 추계학술대회논문집
    • /
    • pp.69-75
    • /
    • 1995
  • The deformation behavior of stainless steel-clad aluminum sheet metals under uniaxial tension has been investigated. The differences in mechanical properties such as elastic modulus, flow stress and plastic strain ratio, of component layers of the composite sheet gave rise to warping of the tensile specimens. The warping has been analyzed by FEM and the total force and momentum equilibria. The analyzed radii of curvature of the warped specimens were smaller than the measured data possibly due to elastic recovery during unloading. The differences in mechanical properties may also give rise to transverse stresses in the component layers. The transverse stresses have been analyzed on the assumption of isostrain and by the FEM in which the warping has been taken into account. The transverse stresses calculated by the FEM were lower than those by the isostrain hypothesis due to stress relaxation by the warping and turned out to be negligible compared with the longitudinal stresses. Consequently, the flow stresses of the composite sheets follow the rule of mixtures.

  • PDF

철근 및 FRP Bar 콘크리트보의 전단변형 특성 (Shear Deformation Characteristics of Concrete Beams Strengthened with Steel/FRP Bar)

  • 신근옥;이창신;김대중;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.277-280
    • /
    • 2006
  • This paper deals with the shear deformation charateristics of concrete beams strengthened with steel/FRP Bar. Applying the shear behavioral model based on shear deformation compatibility to RC beams tested by Ahmed K. El-Sayed et al.(2006), their transverse deformation in the web are calculated at ultimated loads after decoupling the shear carried by arch action in each beams. The calculated transverse deformation at ultimated loads are nearly same for the different reinforcement ratio. From these results, the temporary transverse deformation limit criterion is deduced. Using the proposed temporary limit criterion, the shear strength of concrete beams strengthen with FRP Bar tested by Ahmed K. El-Sayed et al.(2006) is predicted. These predicted values are compared with the measured values and the results are also compared with the current ACI and JSCE equation. The proposed method predicts the ultimate shear capacities more accurately than the equation of ACI and JSCE code. The predictions by the ACI and JSCE code are founded to be very conservative.

  • PDF

하중분배 계수를 적용한 비충전 강합성 바닥판 활하중 모멘트 산정 (Estimation of Live Load Moment for Concrete Unfilled Steel Grid Deck Using Main Bearing Bar Distribution Factor)

  • 박영훈;김성훈
    • 대한토목학회논문집
    • /
    • 제34권6호
    • /
    • pp.1667-1676
    • /
    • 2014
  • 강합성 바닥판은 두 방향의 휨 강성이 다르기 때문에 직교이방성의 성질을 가진다. 강합성 바닥판의 휨 강성비는 활하중 모멘트에 영향을 미친다. 비충전 강합성 바닥판의 휨 강성비는 메인 베아링 바 간격과 직접적인 관계를 가지고 있어 메인 베아링 바 간격과 형상비 영향이 고려된 하중분배 계수식에 대한 연구가 필요한 것으로 판단된다. 본 연구에서는 휨 강성비를 고려하는 AASHTO LRFD Bridge Design Specification에 의한 비충전 강합성 바닥판의 활하중 모멘트를 평가하고 비충전 강합성 바닥판의 하중분배 계수식을 제안하고자 한다.

사각단면 철근콘크리트 교각의 심부구속철근비 제안 (Suggestion for Confinement Steel Ratio of Rectangular RC Bridge Piers)

  • 박창규;정영수;윤상철
    • 콘크리트학회논문집
    • /
    • 제18권6호
    • /
    • pp.749-757
    • /
    • 2006
  • 최근 세계 도처에서 발생한 지진은 수많은 사상자를 발생시키었음은 물론 사회기간시설물에도 많은 피해를 주고 있다. 본 연구에서는 사각형 철근콘크리트 교각의 합리적인 심부구속철근비 산정식을 도출하기 위하여 내진성능에 영향을 미치는 주요 인자에 대하여 분석하였다. 본 연구에서 국내외 54개의 실험 결과를 분석한 결과 축하중비와 주철근비가 변위연성도에 큰 영향을 주는 주요 변수임을 확인하였으나, 이 변수들은 현 도로교설계기준의 심부구속철근비 산정식에는 고려가 되어있지 않고 있다. 따라서 이 실험 결과들을 이용하여 사각형 철근콘크리트 교각의 합리적인 심부구속철근비 산정식을 제안하였다. 본 연구에서 제안된 심부구속철근비 산정식은 기존 규정에 축하중비와 주철근비를 고려하였으며, 또한 낮은 축하중비에서 주철근 좌굴 방지를 위한 최소 규정을 도입하였다. 제안된 식은 일반적인 도로교상의 축하중비를 고려하면 기존 규정에 비해 매우 완화된 심부구속철근비를 갖게 된다. 따라서 문제로 나타나고 있는 시공성과 경제성이 상당히 향상될 수 있으리라 판단된다.

플레이트 거더의 수평보강재 보강 위치 (Reinforcement Location of Plate Girders with Longitudinal Stiffeners)

  • 손병직;허용학
    • 한국안전학회지
    • /
    • 제24권4호
    • /
    • pp.82-89
    • /
    • 2009
  • Unlike concrete bridge, steel bridge resists external force by forming thin plate. Thus, because steel girder bridge has big slenderness ratio, buckling is a major design factor. Plate girder consists of flange and web plate. Because of economic views, web plate that resists shear forces is made by more thinner plate. Thus, web plate has much risk for buckling. The objective of this study is to analyze the buckling behaviors of plate girder and to present the proper reinforcement location of longitudinal stiffeners. Various parametric study according to the change of web height, transverse stiffeners and load condition are examined.

횡보강철근으로 구속된 고강도 콘크리트의 응력-변형률 구속 모델 (A stress-strain Model of High-strength concrete confined with Transverse Reinforcement)

  • 문초화;박종욱;김상우;김길희;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.87-88
    • /
    • 2010
  • 철근콘크리트 기둥은 횡보강철근으로 구속함으로써 부재의 강도 및 연성능력의 증진효과를 얻을 수 있다. 이에 횡보강철근으로 구속된 콘크리트의 응력-변형률 모델이 다양하게 제시되어왔다. 본 연구에서는 고강도 횡보강철근으로 구속한 원형실린더의 최대 횡구속 응력에 영향을 주는 요소를 파악하고 실험결과로부터 콘크리트와 횡보강철근 사이의 변형률을 분석하여 포아송비식을 제안하였다.

  • PDF

직교보를 고려한 RCS구조 보-기둥 접합부의 극한전단강도 (The Ultimate Shear Strength of RCS System Beam-Column Joints Considering the Transverse Beam)

  • 안재혁;박천석
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.158-163
    • /
    • 2005
  • This paper is focusing on the model to predict the ultimate shear strength on joints of composite system (RCS) with reinforced concrete columns and steel beams considering the transverse beam. It reviews the ratio of experimental shear strength to design strength calculated by existing desist equations which are proposed by Kanno, Wight, Noguchi and the rising of strength by the transverse beams. When the shear strength of joints is estimated, it is necessary to do research work for the stress transfer mechanism considering two concrete strut of inner and outer panel by web of the transverse beam. In order to confirm it requires further experimental and analytical study.

Composite action of concrete-filled double circular steel tubular stub columns

  • Wang, Liping;Cao, Xing-xing;Ding, Fa-xing;Luo, Liang;Sun, Yi;Liu, Xue-mei;Su, Hui-lin
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.77-90
    • /
    • 2018
  • This paper presents a combined numerical, experimental, and theoretical study on the behavior of the concrete-filled double circular steel tubular (CFDT) stub columns under axial compressive loading. Four groups of stub column specimens were tested in this study to find out the effects of the concrete strength, steel ratio and diameter ratio on the mechanical behavior of CFDT stub columns. Nonlinear finite element (FE) models were also established to study the stresses of different components in the CFDT stub columns. The change of axial and transverse stresses in the internal and external steel tubes, as well as the change of axial stress in the concrete sandwich and concrete core, respectively, was thoroughly investigated for different CFDT stub columns with the same steel ratio. The influence of inner-to-outer diameter ratio and steel ratio on the ultimate bearing capacity of CFDT stub columns was identified, and a reasonable section configuration with proper inner-to-outer diameter ratio and steel ratio was proposed. Furthermore, a practical formula for predicting the ultimate bearing capacity was proposed based on the ultimate equilibrium principle. The predicted results showed satisfactory agreement with both experimental and numerical results, indicating that the proposed formula is applicable for design purposes.

Seismic performance of RC columns retrofitted using high-strength steel strips under high axial compression ratios

  • Yang, Yong;Hao, Ning;Xue, Yicong;Feng, Shiqiang;Yu, Yunlong;Zhang, Shuchen
    • Structural Engineering and Mechanics
    • /
    • 제84권3호
    • /
    • pp.345-360
    • /
    • 2022
  • In this paper, the impact on seismic performance of an economical effective technique for retrofitting reinforced concrete (RC) columns using high-strength steel strips under high axial compression ratios was presented. The experimental program included a series of cyclic loading tests on one nonretrofitted control specimen and three retrofitted specimens. The effects of the axial compression ratio and spacing of the steel strips on the cyclic behavior of the specimens were studied. Based on the test results, the failure modes, hysteretic characteristics, strength and stiffness degradation, displacement ductility, and energy dissipation capacity of the specimens were analyzed in-depth. The analysis showed that the transverse confinement provided by the high-strength steel strips could effectively delay and restrain diagonal crack development and improve the failure mode, which was flexural-shear failure controlled by flexural failure with better ductility. The specimens retrofitted using high-strength steel strips showed more satisfactory seismic performance than the control specimen. The seismic performance and deformation capacity of the retrofitted RC columns increased with decreasing axial compression ratio and steel strip spacing. Based on the test results, a hysteretic model for RC columns that considers the transverse confinement of high-strength steel strips was then established. The hysteretic model showed good agreement with the experimental results, which verified the effectiveness of the proposed hysteretic model. Therefore, the aforementioned analysis can be used for the design of retrofitted RC columns.

Characteristic Behavior of High-Strength Concrete Columns under Simulated Seismic Loading

  • Hwang, Sun-Kyoung
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권2E호
    • /
    • pp.79-87
    • /
    • 2006
  • The main objective of this research is to examine the behavior of high-strength concrete(HSC) columns. Eight test columns in one-third scale were tested under the conditions of cyclic lateral force and a constant axial load equal to 30% of the column axial load capacity. The $200{\times}200mm$ square columns were reinforced with eight DB bars constituting a longitudinal steel ratio of 2.54% of the column cross-sectional area. The main experimental parameters were volumetric ratio of transverse reinforcement(${\rho}_s$=1.58, 2.25 percent), tie configuration(Type H, Type C, Type D) and tie yield strength($f_{yh}$=548.8 and 779.1 MPa). It was found that the hysteretic behaviour and ultimate deformability of HSC columns were influenced by the amount and details of transverse reinforcement in the potential plastic hinge regions. Columns of transverse reinforcement in the amount 42 percent higher than that required by seismic provisions of ACI 318-02 showed ductile behavior. At 30% of the axial load capacity, it is recommended that the yield strength of transverse reinforcement be held equal to or below 548.8 MPa. Correlations between the calculated damage index and the damage progress are proposed.