• Title/Summary/Keyword: Transport loss

Search Result 600, Processing Time 0.029 seconds

Effect of Changing Amniotic Fluid Osmolarity on the $Li^+$ Transport Through the Membrane Surrounding Amniotic Fluid in the Rabbit

  • Chang, Jin-Keun;Lee, Sang-Jin;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.27 no.1
    • /
    • pp.13-25
    • /
    • 1993
  • To study the regulation of amniotic fluid volume and electrolyte concentration by the Membranes surrounding the amniotic fluid, the rate of $Li^+$ disappearance from amniotic sac of expired fetuses were examined while increasing the amniotic volume and osmolarity in rabbits. After intraamniotic injection of 1 ml isosmotic saline (about 20% of the amniotic fluid volume) containing 15 mM LiCl and 0.5 g/L Censored, the time courses of $Li^+$ and Censored disappearance were determined. From there the $Li^+$ clearance through the extrafetal routes was estimated and compared with that obtained from living fetuses. The volume, $Na^+$ concentration and osmolarity of amniotic fluid were measured and their relationships with $Li^+$ disappearance were evaluated. The fellowing results were obtained: 1. The rate of disappearance from amniotic fluid of living fetuses during the first 30 minutes was strikingly higher for $Li^+$ than for Censored, suggesting that extrafetal routes exist. At 60 and 90 minutes, however, the disappearance rate of $Li^+$ was less than that of Censored, suggesting the possibility of $Li^+$ reentry through fetal urination. 2. The disappearance of $Li^+$ from the amniotic fluid of the expired fetus was substantial, although lower than that of living fetuses, throughout the experimental period. 3. The $Na^+$ concentration and the osmolarity of the amniotic fluid of expired fetus measured 30 minutes after an intraamniotic injection of isoosmotic saline showed wide variation, but thereafter they changed gradually towards the normal extracellular fluid level. 4. When the amniotic fluid was iso- or hyposmolar, the rate of $Li^+$ disappearance from the amniotic fluid of the expired fetuses showed little variation. However, when the amniotic fluid was hyperosmolar, the rate at 30 minutes was markedly lower than those of isosmotic or hyposmotic amniotic fluid. At 90 minutes, the rate of $Li^+$ disappearance in hyperosmolar fluid reached a similar level to the rate in isosmolar fluid. 5. The intraamniotic injection of 400 mOsm/L saline solution decreased the disappearance rate of $Li^+$ from expired fetuses, while the injection of mannitol into the maternal vein induced no significant change. From these results it is concluded that: 1) a significant amount of $Li^+$ may leave the amniotic fluid via filtration through the membranes surrounding the amniotic fluid, 2) during hyperosmolar challenge to amniotic fluid, osmotic bulk flow might counteract the filterable loss, and 3) $Li^+$ disappearance might continue even after the volume and osmolarity of the amniotic fluid have recovered to control values.

  • PDF

Standardization of Underground Shopping Center Address System for the Three-Dimensional GIS-based Emergency Management (3차원 GIS기반의 소방방재를 위한 지하상가 주소체계 표준화)

  • Ha, Byeong Po;Kang, In Joon;Hong, Soon Heon;Park, Dong Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.63-69
    • /
    • 2014
  • Due to population growth and urban development in construction technology has expanded living space, underground construction as public transport as has been extended to the ground and underground urban traffic congestion increases. This underpass Stations sphere of influence this development was the center of the living space, space-time became a cultural space. However underpass ground space and time and space are enormous difficulties in contrast visibility due to smoke when light levels are low fire occurs, momentary loss of judgment errors due to a sense of orientation, rapid diffusion and ambient oxygen deficiency due to acquisition limitations, such as the Open resulting in property damage and personal injury. The purpose of this study is to analyze the existing system with respect to the address of the underground shopping center and system for presenting an address to the underground shopping mall in the basement of the straight and circular in connection with the street name address. Also can be known only to evacuate their citizens to address the position in the event of a fire inside the basement through the underground shopping mall address standardization system, the fire department only address exact location is being judged will be identified.

Mixed-mode simulation of transient characteristics of 4H-SiC DMOSFETs - Impact off the interface changes (Mixde-mode simulation을 이용한 4H-SiC DMOSFETs의 계면상태에서 포획된 전하에 따른 transient 특성 분석)

  • Kang, Min-Seok;Choe, Chang-Yong;Bang, Wook;Kim, Sang-Chul;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.55-55
    • /
    • 2009
  • Silicon Carbide (SiC) is a material with a wide bandgap (3.26eV), a high critical electric field (~2.3MV/cm), a and a high bulk electron mobility (${\sim}900cm^2/Vs$). These electronic properties allow high breakdown voltage, high frequency, and high temperature operation compared to Silicon devices. Although various SiC DMOSFET structures have been reported so far for optimizing performances. the effect of channel dimension on the switching performance of SiC DMOSFETs has not been extensively examined. In this paper, we report the effect of the interface states ($Q_s$) on the transient characteristics of SiC DMOSFETs. The key design parameters for SiC DMOSFETs have been optimized and a physics-based two-dimensional (2-D) mixed device and circuit simulator by Silvaco Inc. has been used to understand the relationship with the switching characteristics. To investigate transient characteristic of the device, mixed-mode simulation has been performed, where the solution of the basic transport equations for the 2-D device structures is directly embedded into the solution procedure for the circuit equations. The result is a low-loss transient characteristic at low $Q_s$. Based on the simulation results, the DMOSFETs exhibit the turn-on time of 10ns at short channel and 9ns at without the interface charges. By reducing $SiO_2/SiC$ interface charge, power losses and switching time also decreases, primarily due to the lowered channel mobilities. As high density interface states can result in increased carrier trapping, or recombination centers or scattering sites. Therefore, the quality of $SiO_2/SiC$ interfaces is important for both static and transient properties of SiC MOSFET devices.

  • PDF

Development and Application of Slime Meter for Evaluation of Slime Thickness in Borehole (굴착공 내 슬라임 두께 평가를 위한 슬라임미터의 개발 및 적용)

  • Hong, Won-Taek;Woo, Gyuseong;Lee, Jong-Sub;Song, Myung Jun;Lim, Daesung;Park, Min-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.10
    • /
    • pp.29-38
    • /
    • 2018
  • The slime formed at the bottom of the borehole causes the excessive displacement and loss of the bearing capacity of the drilled shaft. In this study, the slime meter is developed for the evaluation of the slime based on the electrical properties of the fluid and the slime in the borehole. The slime meter is composed of a probe instrumented with electrodes and temperature sensor and a frame with rotary encoder, so that the slime meter profiles the electrical resistivity compensated with temperature effect along the depth. For the application of the slime meter, three field tests are conducted at a borehole with a diameter of 3 m and a depth of 46.9 m with different testing time and locations. For all the tests, the experimental results show that while electrical resistivities are constantly measured in the fluid, the electrical resistivities sharply increase at the surface of the slime. Therefore, the slime thicknesses are estimated by the differences in the depths of the slime surface and the ground excavation. The experimental results obtained at the same testing point with different testing time show that the estimated thickness of the slime increases by the elapsed time. Also, the estimated slime at the side of the borehole is thicker than that at the center of the borehole. As the slime meter estimates the slime in the borehole by measuring the electrical resistivity with simple equipment, the slime meter may be effectively used for the evaluation of the slime formed at the bottom of the borehole.

High temperature properties of surface-modified Hastelloy X alloy (표면처리에 따른 Hastelloy X 합금의 고온물성)

  • Cho, Hyun;Lee, Byeong-Woo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.4
    • /
    • pp.183-189
    • /
    • 2012
  • Surface treatments and their effects on high temperature properties for the Hastelloy X, which is a promising candidate alloy for high temperature heat-transport system, have been evaluated. For TiAlN and $Al_2O_3$ overlay coatings, the two different PVD (physical vapor deposition) methods using an arc discharge and a sputtering, were applied, respectively. In addition, a different surface treatment method of the diffusion coating by a pack cementation of Al (aluminiding) was also adopted in this study. To achieve enhanced thermal oxidation resistance at $1000^{\circ}C$ by suppressing the inhomogeneous formation of thick $Cr_2O_3$ crust at the surface region, a study for the surface modification methods on the morphological and structural properties of Hastelloy X substrates has been conducted. The structural and compositional properties of each sample were characterized before and after heat-treatment at $1000^{\circ}C$ under air and He environment. The results showed that the Al diffusion coating showed the more enhanced high temperature properties than the overlay coatings such as the suppressed thick $Cr_2O_3$ crust formation and lower wear loss.

Analysis on the Characteristics of the Infra-Gravity Waves inside and outside Pohang New Harbor using a Transfer Function Model (전달함수 모형을 이용한 포항신항 내·외의 외중력파 특성 분석)

  • Cho, Hong-Yeon;Jeong, Weon Mu;Oh, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.3
    • /
    • pp.131-139
    • /
    • 2014
  • Infra-gravity waves (IGWs) with a period of 1~3 minutes are a factor that directly influences the motion analysis of moored ships inside a harbor and longshore sediment transport analysis. If significant levels of IGWs from far seas are transferred to a harbor and amplified, they may cause downtime of large ships and induce economic loss. In this study, transfer characteristics of the IGWs intruding from outside to inside Pohang New Harbor were analyzed using statistical analysis and transfer function of wave data measured at both outside and inside the harbor for around 5 years. Transfer characteristic analysis was limited to events where IGWs had wave heights above 0.1 m. The wave height distribution of inside the harbor was similar to that of outside the harbor, while the wave period variance of the former was larger than that of the latter. The parameters of the transfer function was optimally estimated according to each event. The estimated average RMS error of the wave height inside the harbor was around 0.013 m. The estimated parameters had a strong correlation with the linear combination information of IGW wave height, period, and direction (R = 0.95). The transfer function suggested in this study can quickly and easily estimate information on IGWs inside the harbor using IGW information predicted beforehand, and is expected to reduce damage due to unexpected restrictions on harbor usage.

A Reputation based Cooperative Routing Scheme for End-to-End Reliable Communications in Multi-hop Wireless Networks (다중 홉 무선 네트워크에서 종단 간 신뢰성 통신을 위한 평판 기반의 협력적 라우팅 기법)

  • Kim, Tae-Hoon;Tak, Sung-Woo
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.11
    • /
    • pp.1593-1608
    • /
    • 2009
  • If a certain relay node in multi-hop wireless networks might become a malicious node that does not cooperate with other nodes or a selfish node, network throughput will be dramatically decreased. Most of existing ad hoc routing protocols assuming that the nodes will fully cooperate with other nodes do not resolve the problem of network performance degradation due to malicious and selfish nodes. This paper presents the CARE (Cooperative Ad hoc routing protocol based REputation) scheme incorporating the reputation management that can achieve a multi-hop wireless network with high throughput performance. The proposed scheme provides the horizontal cross-layer approach which can identify misbehaving malicious, selfish nodes dropped out of the hop-by-hop based packet processing in the network and then set up an optimal packet routing path that will detour misbehaving nodes. And the vertical cross-layer approach contained in the CARE scheme attempts to improve the quality of routing paths by exploiting the quality of link information received from the MAC layer. Besides, it provides high TCP throughput by exploiting the reputation values of nodes acquired from the network layer into the transport layer. A case study on experiments and simulations shows that the CARE scheme incorporating vertical and horizontal cross-layer approaches yields better performance in terms of the low rate of packet loss, fast average packet delivery time, and high TCP throughput between end-to-end nodes.

  • PDF

The effect of portal compression sensor on the quality of chest compressions during cardiopulmonary resuscitation (CPR): A mannequin based simulation study (심페소생술 시행 시에 휴대용 압박 센서 활용이 흉부압박의 질에 미치는 영향: 마네킹 기반 시뮬레이션 연구)

  • Yang, Hyun-Mo;Baeck, Kyung-Min;Kim, Kwang-Suk;Yoon, Byung-Gil;Kim, Jin-Woo;Kim, Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.744-750
    • /
    • 2013
  • This study is to collect a basic data of how Cardiopulmonary Resuscitation (CPR) procedure can influence to cardiac arrest patient with and without the Depth Device during the average transport time period. The data has achieved by comparing result sheet of CPR procedure by hands only versus with Depth Device by twenty 1st and 2nd class Emergency Medical Technician (EMT) from five different fire stations in city of Chong-Ju, and twenty Emergency Rescue major students who completed the BLS provide course. The experiment participators experienced loss of compression depth and rate increase over time. However, the CPR procedure with Depth Device shows that both EMT and students to allow maintaining both the compression depth and rate. The experiment leaves a positive result for CPR operators and considers being valuable domain for cardiac arrest patient.

A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy (태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구)

  • Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.324-331
    • /
    • 2013
  • All evacuated tube collector is being constantly studied since it can reduce the conductive heat loss in absorber by using vacuum technology and has advantage of heat transport capacity and quick thermal response in comparatively small temperature difference. This study investigated the dynamic thermal performance of the solar collector with the control condition of solar irradiance and fluid temperature by using performance experimental apparatus which is combined with solar collector and refrigerator, examined the thermal characteristics in definite temperature range of fluid in constant temperature tank by simultaneously measuring refrigerating performance. As a result of it, I deducted the related equation of collector efficiency and found that mean collector efficiency has increased through quick heat transfer characteristics according to increase of outdoor temperature and irradiance in case of outlet temperature of constant temperature tank $22^{\circ}C$ when set outlet temperature of solar collector $25^{\circ}C$ with outlet temperature of constant temperature tank $18^{\circ}C$ & $22^{\circ}C$. Also COP of refrigerator was acquired value of 6.2~7.1 at outlet temperature of constant temperature tank $18^{\circ}C$.

A comparative study of field measurements of the pressure wave with analytical aerodynamic model for the high speed train in tunnels (고속철도 터널내 압력파 측정과 공기압 해석모델에 대한 기초연구)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Hong, Yoo-Jung;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.319-332
    • /
    • 2015
  • The pressure wave formed by the piston effects of the train proceeds within the tunnel when a train enters the tunnel with a high speed. Depending on the condition of tunnel exit, the compression waves reflect at a open end, change to the expansion waves, transfer to tunnel entrance back. Due to interference in the pressure waves and running train, passengers experience severe pressure fluctuations. And these pressure waves result in energy loss, noise, vibration, as well as in the passengers' ears. In this study, we performed comparison between numerical analysis and field experiments about the characteristics of the pressure waves transport in tunnel that appears when the train enter a tunnel and the variation of pressure penetrating into the train staterooms according to blockage ratio of train. In addition, a comparative study was carried out with the ThermoTun program to examine the applicability of the compressible 1-D model(based on the Method of Characteristics). Furthermore examination for the adequacy of the governing equations analysis based on compressible 1-D numerical model by Baron was examined.