• Title/Summary/Keyword: Transport loss

Search Result 600, Processing Time 0.036 seconds

Current Sharing and AC Loss of a Multi-Layer HTS Power Transmission Cable with Variable Cable Length (다층 고온초전도 송전케이블의 길이에 따른 층별 전류분류 및 교류손실 계산)

  • Lee, Ji-Kwang;Cha, Guee-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.1
    • /
    • pp.10-14
    • /
    • 2001
  • The superconducting transmission cable is one of interesting part in power application using high temperature superconducting wire. One important parameter in HTS cable design is transport current sharing because it is related with current transmission capacity and loss. In this paper, we calculate self inductances of each layer and mutual inductances between two layers from magnetic field energy, and current sharing of each layer for 4-layer cable using the electric circuit model which contain inductance and resistance (by joint and AC loss). Also, transport current losses which are calculated by monoblock model and Norris equation are compared. As a results, outer layer has always larger transport current than inner layer, and current capacity of each layer is largely influenced by resistance per unit cable length. As a conclusion, for high current uniformity and low AC loss, we have to decrease inductances themselves or those differences.

  • PDF

Transport current loss of YBCO Coated Conductor and Bi-2223 tape (Bi-2223 선재와 YBCO Coated Conductor 선재의 전송전류 손실 비교)

  • Lim Hyoungwoo;Lee Kwangyoun;Cha Gueesoo;Lee Jikwang;Park Chan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1010-1012
    • /
    • 2004
  • AC loss is an important factor in the development of superconducting tapes and superconducting power applications. In this paper we measured and compared characteristics of BSCCO tape and YBCO Coated Conductor(YBCO CC). BSCCO tape was fabricated by PIT method. We measured critical current density and transport current loss of it. Also, YBCO CC tape consist of substrate. buffer, YBCO and metal layers. We measured critical current density on variations of external magnetic field and transport current loss of these cases. The results of measurement show that normalized critical current of YBCO CC is smaller then that of BSCCO tape in the external magnet field. According to the results. measured loss and calculated of the YBCO CC show the same tendency.

  • PDF

Analysis of transport current loss in HTS tape (고온 초전도 선재에서의 통전 손실 해석)

  • 최세용;이준호;나완수;장석헌;주진호;정재훈;류경우
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.55-57
    • /
    • 2003
  • In this paper, we described the procedures of AC transport current loss in HTS tape. To carry out the calculation, A-$\Phi$ formulation was introduced and two dimensional FEM was used for computation. The results were showed that ellipse shape was higher loss compared to rectangle one and these were almost same behavior of analytical results predicted by Norris. A comparative analysis of loss for various n-value variation was also presented.

  • PDF

Effects of transport time and feeding type on weight loss, meat quality and behavior of broilers

  • Fu, Yajie;Yin, Jingwen;Zhao, Ning;Xue, Ge;Zhang, Runxiang;Li, Jianhong;Bao, Jun
    • Animal Bioscience
    • /
    • v.35 no.7
    • /
    • pp.1039-1047
    • /
    • 2022
  • Objective: The purpose of this study is to determine the optimal time of transportation of floor-feed and scatter-feed broilers. Methods: Eighty healthy Arbor Acres (AA) broilers (21-day-old, 624.4 g, male, standard error = 6.65) were selected and randomly divided into two experimental groups (floor-feed and scatter-feed), then fed for three weeks. The experiment comprised a 2×4 factorial design with 2 feed patterns (floor-feed and scatter-feed) and 4 transport periods (2, 3, 4, and 5 h), and 4 replicates of 5 broilers (54-day-old, 2243 g, standard error = 46.65) was used to compare weight loss, meat quality and behavior index of different groups. Results: It appeared that drip loss, meat color and resting behavior of experimental broilers changed as length of transportation (p<0.05), however, weight loss and pH were not significantly transformed (p>0.05). Compared with floor-feed group, broilers in scatter-feed group had lower pH at 24 hours (3 h) and different behavioral indicators (p<0.05). Especially indicators after 3 h transportation, there were obvious differences between the two feeding modes in the behavior reaction of stress events before slaughter with different transport duration (p<0.05). The fluctuation of data on resting behavior with scatter-feed was significantly higher than that of floor-feed broilers. There was no interaction between transport time and different feeding methods for index tested of our experiment (p>0.05). Conclusion: Comprehensive analysis showed that the maximum transport duration of floor-feed and scatter-feed broilers should not exceed 3 h, and scatter-feed broilers were more likely prone to fear.

Numerical Calculation of AC transport current loss of stacked BSCCO wires (수치해석을 이용한 BSCCO 적층 선재들에 교류 통전시 발생하는 손실 계산)

  • Lim, Hyoung-Woo;Han, Byung-Wook;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.56-58
    • /
    • 2007
  • AC transport current losses is an important factor in the development of superconducting tapes and superconducting power applications. In this paper we compared measurement, calculation and Norris equation of AC transport current loss in BSCCO single and multi stacked wire. And present a distribution flux density and current density in the HTS single wire and multi stacked wire. The result of Measurement and calculation of Ac transport current loss show that the same. And show that HTS characteristic of inside HTS wire.

  • PDF

AC loss analysis and experimental evaluation of a high temperature superconductor (고온초전도선재의 교류손실 해석 및 실험)

  • Ryu, Kyung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.96-100
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current and exposed to an external magnetic field generated by neighboring tape's AC currents simultaneously. AC loss taking into account such real applications is a crucial issue for power applications of the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1.5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured transport losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents. The transport losses do not depend on the frequency of the neighboring tape's AC currents but its arrangements in the range of small current especially.

  • PDF

Analysis of transport current loss considering the conductive layer of YBCO wires (도전성이 높은 안정화층을 고려한 YBCO 선재의 전송전류 손실 해석)

  • Kang, Myung-Hun;Han, Byung-Wook;Jung, Du-Young;Lim, Hee-Hyun;Lim, Hyoung-Woo;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.191-193
    • /
    • 2006
  • YBCO wire has a metal substrate to improve the texture structure and highly conductive layers to increase the cryogenic stability. When AC current flows in the YBCO wire, magnetic field which is generated by the AC current magnetizes the metal substrate and induces the eddy current in the stabilizing layer. To examine the effect of the metal substrate and the conducting layer on the transport current loss of YBCO wire, this paper presents the transport current loss of YBCO wire which has metal substrate and conductive layer. YBCO wire with Ni-W substrate and copper layer were chosen as the model HTS wire for numerical calculation. Finite element method has been used to calculate the transport loss and the results of numerical calculation was compared with analytic calculation suggested by Norris.

  • PDF

Fast transport with wall slippage

  • Tang, Zhipeng;Zhang, Yongbin
    • Membrane and Water Treatment
    • /
    • v.12 no.1
    • /
    • pp.37-41
    • /
    • 2021
  • This paper presents the multiscale calculation results of the very fast volume transport in micro/nano cylindrical tubes with the wall slippage. There simultaneously occurs the adsorbed layer flow and the intermediate continuum fluid flow which are respectively on different scales. The modeled fluid is water and the tube wall is somewhat hydrophobic. The calculation shows that the power loss on the tube no more than 1.0 Watt/m can generate the wall slippage even if the fluid-tube wall interfacial shear strength is 1 MPa; The power loss on the scale 104 Watt/m produces the volume flow rate through the tube more than one hundred times higher than the classical hydrodynamic theory calculation even if the fluid-tube wall interfacial shear strength is 1 MPa. When the wall slippage occurs, the volume flow rate through the tube is in direct proportion to the power loss on the tube but in inverse proportion to the fluid-tube wall interfacial shear strength. For low interfacial shear strengths such as no more than 1 kPa, the transport in the tube appears very fast with the magnitude more than 4 orders higher than the classical calculation if the power loss on the tube is on the scale 104 Watt/m.

Current Distribution and Numerical Analysis of AC Losses on Multi-Layer HTS Cable (다층 고온 초전도 케이블의 전류 분포 및 교류손실 해석)

  • 김영석;이병성;장현만;곽민환;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.452-455
    • /
    • 2000
  • Superconducting power cable is one of the most promising energy application of high-T$_{c}$ superconductors (HTS). A prototype HTS cable have been constructed multi-layer cable using Bi-2223 tape and tested. The AC transport losses under self field were investigated at 77K on the 19 filamentary tape and multi-layer HTS cables. And we carried out numerical analysis using bean model. The result shows that the total transport current of HTS cable in L$N_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to I$^2$ and higher than losses of inner layer. In case of Ip=Ic, calculated numerical loss density was concentrated on the edge of tape and most of loss density in cable was distributed outer layer more than inner layer. As magnetic distribution was concentrated on outer layer.r.

  • PDF

The AC loss of 22.9kV/50MVA High-Tc Superconducting Power Cable (22.9kV/50MVA급 고온초전도 전력케이블의 교류손실)

  • Choi, Suk-Jin;Lee, Sang-Jin;Sim, Ki-Deok;Cho, Jeon-Wook;Lee, Soo-Gil;Yang, Byeong-Mo;Yoon, Hyung-Hee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.31-34
    • /
    • 2009
  • An HTS power cable is generally composed of 2 layers for conducting and 1 layer for shielding. For the analysis of AC loss of an HTS power cable, 2-dimensional magnetic field analysis is carried out. The magnetization loss in HTS cable core was calculated, and the transport current loss was obtained from the monoblock equation and the elliptical Norris Equation. And the total AC loss of the cable was expected by the sum of magnetization loss and transport current loss. The variation of ac loss with respect to the gap and uncertain factor between the superconducting tapes was investigated, and the ac loss of 22.9kV/50MVA high-Tc superconducting power cable was calculated. These results well agree with those of experiment.