• 제목/요약/키워드: Transmission-Line Transformer

검색결과 116건 처리시간 0.028초

변류기를 이용한 자가발전 장치의 설계와 특성 (Design and Properties of a Self Generation Equipment using Current Transformer)

  • 변우봉;김현식;김종령;이해연;이준희;지민권;이진;오영우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.427-428
    • /
    • 2008
  • We have studied design and application about an self generation equipment for underground power transmission cable. The split CT(Current Transformer), which has the applicable underground power transmission cable, was manufactured through electromagnetic simulation of magnetic core. And manufactured the AC-DC converter that supplied stable DC power for PLC modem when current of power line has more than 150A. An self generation equipment using the CT and AC-DC converter get into operation the PLC modem consistently. As a result, the underground power transmission cable was showed the application possibility through the stable communication and network characteristics.

  • PDF

이중 대역 L형 임피던스 변환기 (Dual-band L-section Impedance Transformer)

  • 박면주
    • 한국ITS학회 논문지
    • /
    • 제9권5호
    • /
    • pp.67-71
    • /
    • 2010
  • 본 논문에서는 L-형 회로구조에 기반한 새로운 이중대역 임피던스 변환기를 제안한다. 제안된 회로는 전원 또는 부하단에 하나의 스터브 선로가 부착된 전송선로를 사용하여 구성된다. 각 회로 구조와 부하조건에 대해 이중대역 동작조건을 자세히 분석하였으며 이로부터 선로의 길이와 임피던스 등의 이중대역 설계 공식을 간단한 형태로 유도하였다. 제안된 방법을 이용하여 이중대역 임피던스 정합회로를 설계하고 마이크로스트립 회로로 제작, 측정하여 이중대역 동작을 확인하였다.

Grid-Connected Three-Phase Inverter System with Sub Inverter using Combination Type UPFC Structure

  • Park, Seong-Mi;Vi, Le Thi Tuan;Jeong, Da-Woom;Park, Sung-Jun;Park, Jang-Sik
    • 한국산업융합학회 논문집
    • /
    • 제23권4_1호
    • /
    • pp.559-567
    • /
    • 2020
  • As the renewable energy market grows, grid-connected inverters have been improving and expanding in several fields in recent years because energy conversion devices are the main components of solar systems. In this paper, a high-precision new grid-connected three-phase inverter system is proposed. The proposed system consists of a main inverter, a sub inverter and a transformer. The main inverter operates at a low switching frequency and high power and transmits power to the grid. A sub-inverter connected in series with the transmission line through a matching transformer operates at lower power than the main inverter to provide input values to the transformer. The transformer acts as a power supply according to the voltage compensation value. This study is based on the principle of operation of the UPFC(Unified Power Flow Controller) structure used to regulate power flow in AC transmission lines. The grid-connected inverter system proposed in this paper is implemented with high precision and high resolution. The proposed system was verified through its ability to enhance and ensure the safety of the proposed system through simulation and experiment.

Analysis of Economic Replacement Cycle of Power Transformer Based on LCC Considering Maintenance Effect

  • Park, Seung-Hwa;Jang, Kyeong-Wook;Kweon, Dong-Jin;Shon, Jin-Geun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1631-1637
    • /
    • 2018
  • Electric utilities has been considered the necessity to introduce asset management of electric power facilities in order to reduce maintenance cost of existing facilities and to maximize profit. This paper aims to provide data that can helpful to make profitable decision in terms of power transformers which have a significant part in the power system. Therefore, this study is modeling input cost for power transformer during its entire life and also the life cycle cost (LCC) technique is applied. In particular, the variation of transformer state related with maintenance and the variation of the EUAC curve based on cost and effect of maintenance is examined. In this study, the trend of the equivalent uniform annual cost (EUAC) according to maintenance cycle and cost of equipment is analyzed. In line with that, sensitivity analysis influenced by the changes of other cost factors was performed.

변압기 부분방전과 노이즈에 의한 초음파 신호 분석 (Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer)

  • 권동진;정길조;진상범;곽희로
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.

혼합송전계통에서 재폐로 해석을 위한 모델수립 및 개폐과전압해석 (Modeling and Switching Overvoltage Analysis for Reclosing Analysis in Combined Transmission Systems)

  • 임광식;이종범;강지원;정채균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.442-443
    • /
    • 2008
  • This paper describes modeling using the EMTP/ATPDraw for reclosing analysis in 154kV combined transmission systems, and analyzes switching overvoltage. Current transformer established at lead-in area and lead-out area in transmission line and circuit breaker were modeled using TACS in the EMTP/ATPDraw. And also MODELS was constructed by signal processing of the operating reclosing. The simulation was carried out the switching overvoltage according to the length of overhead and underground transmission line, overvoltage between sheath and earth, and voltage between joint boxes.

  • PDF

경부고속철도 시험선구 고조파 예측에 관한 연구 (A study of the harmonics evaluation in the test track of Korea High Speed Rail)

  • 김길상;오광해;권삼영;이태형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.241-248
    • /
    • 1998
  • The purpose of this study is to evaluate the harmonics generated from Korea High Speed Rail's trainset and to analyze the effect on the KEPCO power system. This study focuses on the test track of the high speed rail and analyzes 154㎸ transmission line, scott transformer, autotransformer and 27,5㎸ line. The trainset is modeled as a harmonic source attached to the catenary line of the test track. Then, harmonic distortion is calculated. This distortion is compared with the KEPCO's regulations in relation to harmonic.

  • PDF

레일 전력선통신을 위한 임피던스 정합방안 연구 (A Study on an Impedance Matching Technique for Rail Power Line Communication)

  • 서일권;안승호;김철수
    • 한국산학기술학회논문지
    • /
    • 제17권11호
    • /
    • pp.202-207
    • /
    • 2016
  • 장대 터널 및 급곡선 구간과 같은 시계 확보가 어려운 지역에서 위험 및 안전 정보를 함께 공유하기 위해서는 기관사, 열차 관제사 및 현장 작업자 사이에 보조적인 실시간 열차 정보 통신시스템의 개발이 필요하다. 이에 적합한 열차 정보 통신시스템을 개발하기 위하여 본 연구에서는 작은 노이즈와 신호 감쇄를 동시에 갖도록 하는 레일 전력선 통신을 제안하였다. 이에 대한 레일 전력선 통신의 기초 연구 일환으로서, 본 통신기법의 전송 특성을 향상할 수 있는 레일에 대한 임피던스 측정 및 정합특성 평가가 중요하다. 본 연구에서는 자체 제작한 임피던스 정합 트랜스포머와 네트워크 분석기를 이용하여 레일에 대한 반사 및 전파 특성을 평가하였다. 대향 접속방식의 임피던스 반사특성 시험결과로부터 레일 전력선 통신에 적합한 정합용 트랜스포머의 정합비율은 1:3.28임을 알 수 있었다. 또한, 제작한 임피던스 정합용 트랜스포머는 레일 전력선통신에서 투과 신호 전송을 향상할 수 있음을 확인하였다.

전송선로 모델을 이용한 마이크로스트립 슬롯 배열 안테나 설계 (Microstrip Slot Array Antenna Design by Using Tansmission Line Model)

  • 한석진;박익모;신철재
    • 한국전자파학회논문지
    • /
    • 제11권4호
    • /
    • pp.610-618
    • /
    • 2000
  • 본 논문은 T-모양 급전션을 갖는 마이크로스트립 슬롯 안테나를 전송선로 모델로 해석을 하였다. 마이크로스 트립 선로와 슬롯 선로의 접합변을 트랜스포머로 모델링을 하였으며 실험적인 방법으로 트랜스포머의 turn ratio 를 유도하였다. 전송선로 모델을 이용하여 단일 안테나뿐만 아니라 $1\times2,l\times4$ 배열 안테나를 해석하여 설계하 였고 제착하여 전송선로 모델로 계산한 반사손실 값과 측정값의 비교를 통해 전송선로 모텔이 안테나 설계에 유 용함을 입증하였다. 측정한 단일 안테나, $1\times2,l\times4$배열 안테나의 대역폭은 VSWR $\leq2$를 기준으로 하여 각각 2 28.5%, 47.8% 50.9% 였고 $1\times4$배열 안테나의 E-명변에서 주빔의 3dB 빔폭은 약$27^{\circ}$ 이득은 7.97 dBi 였다.

  • PDF

광대역 다단 전력 분배기의 일반화된 설계 방법 (A General Design Method for the Broadband Multi-Section Power Divider)

  • 박준석;김형석;임재봉
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.85-91
    • /
    • 2002
  • A novel multi-section power divider configuration is Proposed to obtain wide-band frequency performance up to microwave frequency region. Design procedures for the proposed microwave broadband power divider are composed of a Planar multi-section three-Ports hybrid and a waveguide transformer design procedures. The multi∼section power divider is based on design theory of the optimum quarter- wave transformer Furthermore, in order to obtain the broadband isolation performance between the two adjacent output ports, the odd mode equivalent circuit should be matched by using the lossy element such as resistor. The derived design formula for calculating these odd mode∼matching elements is based on the singly terminated filter design theory. The waveguide transformer section is designed to suppress the propagation of the higher order modes such as waveguide modes due to employing the metallic electric wall. Simulation and experiment show excellent performance of multi section power divider.