• Title/Summary/Keyword: Transmission range

Search Result 1,873, Processing Time 0.043 seconds

Performance Evaluation of Underwater Acoustic Communication in Frequency Selective Shallow Water (주파수 선택적인 천해해역에서 수중음향통신 성능해석)

  • Park, Kyu-Chil;Park, Jihyun;Lee, Seung Wook;Jung, Jin Woo;Shin, Jungchae;Yoon, Jong Rak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.95-103
    • /
    • 2013
  • An underwater acoustic (UWA) communication in shallow water is strongly affected by the water surface and the seabed acoustical properties. Every reflected signal to receiver experiences a time-variant scattering in sea surface roughness and a grazing-angle-dependent reflection loss in bottom. Consequently, the performance of UWA communication systems is degraded, and high-speed digital communication is disrupted. If there is a dominant signal path such as a direct path, the received signal is modeled statistically as Rice fading but if not, it is modeled as Rayleigh fading. However, it has been known to be very difficult to reproduce the statistical estimation by real experimental evaluation in the sea. To give an insight for this scattering and grazing-angle-dependent bottom reflection loss effect in UWA communication, authors conduct experiments to quantify these effects. The image is transmitted using binary frequency shift keying (BFSK) modulation. The quality of the received image is shown to be affected by water surface scattering and grazing-angle-dependent bottom reflection loss. The analysis is based on the transmitter to receiver range and the receiver depth dependent image quality and bit error rate (BER). The results show that the received image quality is highly dependent on the transmitter-receiver range and receiver depth which characterizes the channel coherence bandwidth.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

A study on improvement of ISO/IEC 29157 MAC protocol (ISO/IEC 29157 표준 MAC 프로토콜 개선 연구)

  • Cha, Bong-Sang;Jeong, Eui-Hoon;Jeon, Gwangil;Seo, Dae-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.17-26
    • /
    • 2013
  • ISO/IEC 29157 originally developed in the Republic of Korea and is based on commercially available PicoCast v1.0. ISO/IEC JTC1 SC6 was registered by the international standard on May 2010. A single platform for a variety of applications and media formats to support development objectives were. ISO/IEC 29157 based wireless networks, ie, Pico-net to master node periodically transmit sync signal is synchronized to the number of slave nodes have the communications structure. Pico-net also supports a variety of network topologies and direct communication between nodes(single-hop communication) and QoS is guaranteed. But Pico-net network structure has the following problems. Loss of communication problems due to mobile nodes, resulting in limitations of node mobility and wireless network operation range of conventional wireless networks operating range less than 1/4 was reduced to the problem. In this paper, a possible solution to the problems mentioned is proposed, using multi-hop communication technology and sync signal transmission technology between nodes.

The Design and Characteristics of the Inductive Coupler Using the Nanocrystalline Materials (나노 결정립 재료를 이용한 비접촉식 커플러의 설계 및 특성)

  • Kim, Jong-Ryung;Kim, Hyun-Sik;Huh, Jeong-Sub;Lee, Hae-Yeon;Lee, Jun-Hui;Oh, Young-Woo;Byun, Woo-Bong
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.6
    • /
    • pp.300-304
    • /
    • 2006
  • The varied heating temperatures were used for magnetic core materials, which nano sized ${\alpha}-Fe$ crystalline was created in nanocrystalline Fe-Si-B-Nb-Cu materials, with hish permeability and low power loss. The highest permeability and lowest power loss were obtained to the specimen heat-treated at $510^{\circ}C$. The signal transmission characteristics of inductive coupler, which was manufactured by using the magnetic core materials prepared in this study, at low frequency range, was influenced strongly by magnetic property of magnetic core materials as this result is corresponding to the permeability as a function of heat treatment temperature, as well, it was improved by impedance matching at high frequency range. Over $500{\mu}m$ of air gap in coupler is required to maintain the magnetic properties without magnetic saturation on the subterranean line transferred hish current of 300 A. The inductive coupler for PLC, which has an attenuation characteristics of less than 5dB, was manufactured using nano-crystalline magnetic core materials through the above mentioned research results.

Design of Q-Band LC VCO and Injection Locking Buffer 77 GHz Automotive Radar Sensor (77 GHz 자동차용 레이더 센서 응용을 위한 Q-밴드 LC 전압 제어 발진기와 주입 잠금 버퍼 설계)

  • Choi, Kyu-Jin;Song, Jae-Hoon;Kim, Seong-Kyun;Cui, Chenglin;Nam, Sang-Wook;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.399-405
    • /
    • 2011
  • In this paper, we present the design of Q-band LC VCO and injection locking buffer for 77 GHz automotive radar sensor using 130 nm RF CMOS process. To improve the phase noise characteristic of LC tank, the transmission line is used. The negative resistance by the active device cross-coupled pair of buffer is used for high output power, with or without oscillation of buffer. The measured phase noise is -102 dBc/Hz at 1 MHz offset frequency and tuning range is 34.53~35.07 GHz. The output power is higher than 4.1 dBm over entire tuning range. The fabricated chip size is $510{\times}130\;um^2$. The power consumption of LC VCO is 10.8 mW and injection locking buffer is 50.4 mW from 1.2 V supply.

Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module (고감도 보급형 방사선 측정센서 모듈 개발)

  • Oh, Seung-Jin;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.510-514
    • /
    • 2022
  • In this paper, we propose the development of high-sensitivity low-end radiation measuring sensor module. The proposed measurement sensor module is a scintillator + photomultiplier(SiPM) sensor optimization structure design, amplification and filter and control circuit design for sensor driver, control circuit design including short-distance communication, sensor mechanism design and manufacturing, and GUI development applied to prototypes consists of, etc. The scintillator + photomultiplier(SiPM) sensor optimization structure design is designed by checking the characteristics of the scintillator and the photomultiplier (SiPM) for the sensor structure design. Amplification, filter and control circuit design for sensor driver is designed to process fine scintillation signal generated by radiation with a scintillator using SiPM. Control circuit design including short-distance communication is designed to enable data transmission through MCU design to support short-range wireless communication function and wired communication support. The sensor mechanism design and manufacture is designed so that the glare generated by wrapping a reflective paper (mirroring) on the outside of the plastic scintillator is reflected to increase the efficiency in order to transmit the fine scintillation signal generated from the plastic scintillator to the photomultiplier(SiPM). The GUI development applied to the prototype expresses the date and time at the top according to each screen and allows the measurement unit and time, seconds, alarm level, communication status, battery capacity, etc. to be expressed. In order to evaluate the performance of the proposed system, the results of experiments conducted by an authorized testing institute showed that the radiation dose measurement range was 30 𝜇Sv/h ~ 10 mSv/h, so the results are the same as the highest level among products sold commercially at domestic and foreign. In addition, it was confirmed that the measurement uncertainty of ±7.4% was measured, and normal operation was performed under the international standard ±15%.

Transferring Calibrations Between on Farm Whole Grain NIR Analysers

  • Clancy, Phillip J.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1210-1210
    • /
    • 2001
  • On farm analysis of protein, moisture and oil in cereals and oil seeds is quickly being adopted by Australian farmers. The benefits of being able to measure protein and oil in grains and oil seeds are several : $\square$ Optimize crop payments $\square$ Monitor effects of fertilization $\square$ Blend on farm to meet market requirements $\square$ Off farm marketing - sell crop with load by load analysis However farmers are not NIR spectroscopists and the process of calibrating instruments has to the duty of the supplier. With the potential number of On Farm analyser being in the thousands, then the task of calibrating each instrument would be impossible, let alone the problems encountered with updating calibrations from season to season. As such, NIR technology Australia has developed a mechanism for \ulcorner\ulcorner\ulcorner their range of Cropscan 2000G NIR analysers so that a single calibration can be transferred from the master instrument to every slave instrument. Whole grain analysis has been developed over the last 10 years using Near Infrared Transmission through a sample of grain with a pathlength varying from 5-30mm. A continuous spectrum from 800-1100nm is the optimal wavelength coverage fro these applications and a grating based spectrophotometer has proven to provide the best means of producing this spectrum. The most important aspect of standardizing NIB instruments is to duplicate the spectral information. The task is to align spectrum from the slave instruments to the master instrument in terms of wavelength positioning and then to adjust the spectral response at each wavelength in order that the slave instruments mimic the master instrument. The Cropscan 2000G and 2000B Whole Grain Analyser use flat field spectrographs to produce a spectrum from 720-1100nm and a silicon photodiode array detector to collect the spectrum at approximately 10nm intervals. The concave holographic gratings used in the flat field spectrographs are produced by a process of photo lithography. As such each grating is an exact replica of the original. To align wavelengths in these instruments, NIR wheat sample scanned on the master and the slave instruments provides three check points in the spectrum to make a more exact alignment. Once the wavelengths are matched then many samples of wheat, approximately 10, exhibiting absorbances from 2 to 4.5 Abu, are scanned on the master and then on each slave. Using a simple linear regression technique, a slope and bias adjustment is made for each pixel of the detector. This process corrects the spectral response at each wavelength so that the slave instruments produce the same spectra as the master instrument. It is important to use as broad a range of absorbances in the samples so that a good slope and bias estimate can be calculated. These Slope and Bias (S'||'&'||'B) factors are then downloaded into the slave instruments. Calibrations developed on the master instrument can then be downloaded onto the slave instruments and perform similarly to the master instrument. The data shown in this paper illustrates the process of calculating these S'||'&'||'B factors and the transfer of calibrations for wheat, barley and sorghum between several instruments.

  • PDF

W-type hexaferrite-epoxy composites for wide-band radar absorption (광대역 레이다 흡수용 W-type 육방정 페라이트-에폭시 복합 소재)

  • Su-Mi Lee;Tae-Woo Lee;Young-Min Kang;Hyemin Kim
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.42-50
    • /
    • 2023
  • In this study, hexagonal ferrite powder with chemical formula SrZn2-xCoxFe16O27 was synthesized by a solid-state reaction method and its electromagnetic (EM) wave absorption characteristics were evaluated in the frequency range of 0.1-18 GHz with absorber thickness range of 0 - 10 mm. Reflection loss (RL) affecting electromagnetic wave absorption performance was calculated based on the transmission line theory using measured complex permeabilities and permittivities. RL spectra were also directly measured for some samples. They were well matched with calculated results. High-frequency complex permeability characteristics were changed gradually according to the amount of Co substitution (x). The EM wave absorption frequency band could be tuned accordingly. Hexaferrite samples with x = 1.0, 1.25, and 1.5 exhibited remarkable maximum electromagnetic wave absorption performances with minimum RL (RLmin) lowered than -50 dB. They also showed a very broad frequency band (Δf > 10 GHz) in which more than 90% of the EM wave energy absorption occurred (RL ≤ -10 dB).

Exosomes isolation from bovine serum: qualitative and quantitative comparison between ultracentrifugation, combination ultracentrifugation and size exclusion chromatography, and exoEasy methods

  • Eun-Yeong Bok;Sang Young Seo;Han Gyu Lee;Sudu Hakuruge Madusha Pramud Wimalasena;Eunju Kim;Ara Cho;Young-Hun Jung;Tai-Young Hur;Kyoung-Min So;Sung-Lim Lee;Yoon Jung Do
    • Journal of Animal Science and Technology
    • /
    • v.66 no.5
    • /
    • pp.1021-1033
    • /
    • 2024
  • Exosomes have been extensively studied as disease biomarker in humans, given their role in transporting bioactive molecules. However, despite the great potential of exosomes as noninvasive diagnostic markers and therapeutic nanocarriers for bovine diseases, few studies have been conducted on bovine exosome. Thus, this study aimed to quantitatively and qualitatively compare three isolation methods to identify a suitable method for bovine serum. Exosomes were isolated using ultracentrifugation alone (UC), a combination of ultracentrifugation and size exclusion chromatography (US), or membrane affinity-based exoEasy kit (EE). Isolated particles were evaluated using a range of complementary techniques. Transmission electron microscopy showed that all three isolation methods resulted in particles with a cup-shaped morphology. The particle concentration measured by nanoparticle trafficking analyzer of US was lower compared to those of UC and EE method. As a result of immunoblotting, exosome markers including TSG101, CD81, and HSP70 were detected in US particles, while in UC and EE, only TSG101 expression was confirmed. Particles isolated from UC and EE showed a contamination with the blood protein albumin, whereas particles from US did not show albumin contamination. In addition, to evaluate the possibility of using exosomes as biomarkers, the profiles of the small RNA in the exosomes were compared using the bioanalyzer 2100. As a result, in the EE method, the band of small RNA (25-200 nt) was most prominent, and in the US methods, a distinct band was observed in the small RNA range. Collectively, the purity of exosomes without non-exosomal contamination was highest in the US method. However, for the detection of small RNA, the EE method was found to be the most suitable. Therefore, the results suggest that the optimal isolation method varies depending on the specific purpose of exosome isolation.

MSC(Multi-Spectral Camera) 열제어 시스템 소개

  • Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Park, Jong-Euk;Jang, Young-Jun
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.107-116
    • /
    • 2005
  • As a unique payload of Komsat-2, MSC, comprising EOS(Electro-Optical Sub-system), PMU(Payload Management Unit) and PDTS(Payload Data Transmission Sub-system), is supposed to take pictures of one panchromatic and 4 multi-spectral image between wavelength 450mm~900mm, and is being under final Satellite I&T. It will perform the earth remote sensing with applications such as acquisition of high resolution images, surveillance of large scale disasters and its countermeasure, survey of natural resources, etc.. Under the hostile influence of the extreme space environmental conditions due to deep space and direct solar flux, the thermal design is especially of major importance in designing a payload. There are tight temperature range restrictions for electro-optical elements while on the other hand there are low power consumption requirements due to the limited energy source on the spacecraft. This paper describes details of thermal control system for MSC.

  • PDF