• 제목/요약/키워드: Transmission Range

검색결과 1,870건 처리시간 0.023초

A Cross-layer Link Adaptive HD Video Transmission Scheme in WiMedia D-MAC based UWB Systems

  • Joo, Yang-Ick
    • 한국멀티미디어학회논문지
    • /
    • 제15권12호
    • /
    • pp.1464-1474
    • /
    • 2012
  • In this paper, we propose a QoS (Quality of Service)-aware and cooperative resource reservation scheme using cross-layer link adaptation for wireless high definition video transmission through UWB (Ultra Wide Band) network with D-MAC (Distributed Medium Access Control). A wireless high definition video transmission system usually requires stable high throughput even without line-of-sight, e.g., a destination device in another room separated by a wall. Since the WiMedia D-MAC supporting DRP (Distributed Reservation Protocol) scheme causes lots of DRP resource reservation conflicts due to failure of beacon detection in wireless channel environment, overall performances of the WiMedia D-MAC can be deteriorated. And the current WiMedia MAC standard has not considered QoS provisioning even though QoS parameters such as a range of service rates are provided to each traffic stream. Therefore, we propose Relay DRP protocol with QoS-based relay node selection criterion, which makes a relay path to avoid DRP resource reservation conflicts and guarantee QoS more stably through cross-layer link adaptation of cooperative relay transmission scheme and is compliant with the current WiMedia D-MAC protocol. Simulation results demonstrate performance improvements of the proposed method for throughput and QoS provisioning.

Study on Characteristics of Various RF Transmission Line Structures on PES Substrate for Application to Flexible MMIC

  • Yun, Young;Kim, Hong Seung;Jang, Nakwon
    • ETRI Journal
    • /
    • 제36권1호
    • /
    • pp.106-115
    • /
    • 2014
  • In this work, the coplanar waveguide is fabricated on a PES (poly[ether sulfone]) substrate for application to a flexible monolithic microwave integrated circuit, and its RF characteristics were thoroughly investigated. The quality factor of the coplanar waveguide on PES is 40.3 at a resonance frequency of 46.7 GHz. A fishbone-type transmission line (FTTL) structure is also fabricated on the PES substrate, and its RF characteristics are investigated. The wavelength of the FTTL on PES is 5.11 mm at 20 GHz, which is 55% of the conventional coplanar waveguide on PES. Using the FTTL, an impedance transformer is fabricated on PES. The size of the impedance transformer is $0.318mm{\times}0.318mm$, which is 69.2% of the size of the transformer fabricated by the conventional coplanar waveguide on PES. The impedance transformer showed return loss values better than -12.9 dB from 5 GHz to 50 GHz and an insertion loss better than -1.13 dB in the same frequency range.

대용량 WDM 전송을 위한 분산 제어 광 링크 구조 설계 (Design of Dispersion Managed Optical Link for Wideband WDM Transmission)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제12권3호
    • /
    • pp.201-207
    • /
    • 2008
  • 대용량 WDM 전송 시스템의 구현을 위해 중간에 광 위상 공액기 (optical phase conjugator)를 갖는 광섬유에서 축적된 분산량을 precompensation과 postcompensation으로 조절하는 분산 제어 (DM; dispersion management) 전송 링크의 설계 기준을 제시하였다. 본 논문에서 살펴본 DM 구조는 precompensation과 postcompensation가 이루어지는 위치에 따라 bi-end 형태와 concentration 형태의 두 가지이다. 전송 링크 설계 파라미터인 송신기부터 OPC까지의 구간과 OPC부터 수신기까지의 유효 잉여 분산 범위는 OPC에 대해서만 대칭되어 있으면 precompensation과 postcompensation을 수행하는 분산 보상 광섬유(DCF; dispersion compensating fiber)의 위치에 크게 의존하지 않는다는 것을 확인하였다.

  • PDF

고효율 마이크로파 무선 전력 수신 집적회로 설계 및 구현 (A Design of High Efficiency Microwave Wireless Power Acceptor IC)

  • 정원재;정효빈;김상규;장종은;박준석
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1125-1131
    • /
    • 2013
  • Wireless power transmission technology has been studied variety. Recently, wireless power transmission technology used by resonance and magnetic induction field is applied to various fields. However, magnetic resonance and inductive coupling are have drawbacks - power transmission distance is short. Microwave transmission and accept techniques have been developed to overcome short distance. However, improvement in efficiency is required. This paper, propose a high-efficiency microwave energy acceptor IC(EAIC). Suggested EAIC is consists of RF-DC converter and DC-DC converter. Wide Input power range is -15 dBm ~ 20 dBm. And output voltage is boosted up to 5.5 V by voltage boost-up circuit. EAIC can keep the output voltage constant. Available efficiency of RF-DC converter is 95.5 % at 4 dBm input. And DC-DC efficiency is 94.79 % at 1.1 mA load current. Fully EAIC efficiency is 90.5 %.

A Study on the Gustafson-Kessel Clustering Algorithm in Power System Fault Identification

  • Abdullah, Amalina;Banmongkol, Channarong;Hoonchareon, Naebboon;Hidaka, Kunihiko
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1798-1804
    • /
    • 2017
  • This paper presents an approach of the Gustafson-Kessel (GK) clustering algorithm's performance in fault identification on power transmission lines. The clustering algorithm is incorporated in a scheme that uses hybrid intelligent technique to combine artificial neural network and a fuzzy inference system, known as adaptive neuro-fuzzy inference system (ANFIS). The scheme is used to identify the type of fault that occurs on a power transmission line, either single line to ground, double line, double line to ground or three phase. The scheme is also capable an analyzing the fault location without information on line parameters. The range of error estimation is within 0.10 to 0.85 relative to five values of fault resistances. This paper also presents the performance of the GK clustering algorithm compared to fuzzy clustering means (FCM), which is particularly implemented in structuring a data. Results show that the GK algorithm may be implemented in fault identification on power system transmission and performs better than FCM.

In Situ Estimation of the Constituents of Green Soybean (Edamame) Pod using Near-Infrared Transmission Spectroscopy

  • Suzuki, Michiru;Katahira, Mitsuhiko;Natsuga, Motoyasu
    • Journal of Biosystems Engineering
    • /
    • 제39권4호
    • /
    • pp.352-356
    • /
    • 2014
  • Purpose: We estimated the dietary qualities of green soybean (edamame) by using a specialized NIR transmission spectrometer to determine the constitutive properties of the soybean, such as the sucrose content and ninhydrine reaction quantity (NRQ; defined by the ninhydrine reaction, which has a high positive correlation with the total free amino acids), with the purpose of establishing a quality assurance system. Methods: We used a newly developed spectrometer probe that enables in situ estimation of the constituents of the soybean. Results: The calibration results obtained using a wavelength range of 760-960 nm were characterized by $R^2$ = 0.57 and standard error of cross-validation (SECV) of 0.78% for sucrose, and $R^2$ = 0.59 and SECV = 0.35% for NRQ. Conclusions: These results are inferior to those of our previous study obtained using a specialized bench-type transmission spectrometer. The poorer results are attributed to several possible reasons, including the effect of direct sunlight and the unstable sample presentation. We plan to conduct further study using improved optical layout and sample presentation.

전체 잉여 분산이 영인 WDM 전송 링크에서 광 중계 거리 당 잉여 분산 제어를 통한 성능 향상 (Performance Improvements through Controling Residual Dispersion Per Span in WDM Transmission Links with Zero Net Residual Dispersion)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제13권5호
    • /
    • pp.656-661
    • /
    • 2009
  • 전체 잉여 분산 (NRD; net residual dispersion)이 영인 inline 분산 제어 (DM; dispersion management)가 적용된 광전송 링크에서 precompensation, postcompensation과 광 중계 거리 당 잉여 분산 (RDPS; residual dispersion per span)의 제어를 통해 $24{\times}40$ Gbps WDM 신호의 고품질 전송을 연구하였다. 시스템 성능을 양호하게 하는 RDPS 값은 WDM 채널 입사 전력에 의존하지만, 비교적 넓은 입사 전력 범위를 갖는 WDM 신호들의 시스템 성능을 동시에 효율적으로 개선할 수 있는 최적 RDPS는 210~230 ps/nm인 것을 확인하였다. 또한 RDPS가 증가할수록 최악 채널의 눈 열림 패널티 (EOP; eye opening penalty)를 1 dB 이하로 만드는 유효 입사 전력 범위가 증가되는 것을 확인하였다.

  • PDF

EL-SEP: Improved L-SEP by adding Single-hop layer

  • LEE, WooSuk;Jung, Kye-Dong;Lee, Jong-Yong
    • International journal of advanced smart convergence
    • /
    • 제6권1호
    • /
    • pp.50-56
    • /
    • 2017
  • Wireless sensor nodes have limited energy, so it is important to optimize energy consumption to preserve network lifetime. Various protocols have been proposed for this purpose. LEACH protocol and SEP are the representative protocols. These protocols become less effective as the Sensor Field becomes wider. To improve this, MR-SEP and L-SEP were proposed. These protocols increase the energy efficiency by dividing the Sensor Field into layers and reducing the transmission distance. However, when dividing a layer, there are cases where it is divided inefficiently, and a node within a certain range from a Base Station has a better transmission efficiency than a direct transmission method using a cluster method. In this paper, we propose a Single-hop layer for L-SEP to improve inefficient layer division and near node transmission efficiency. When the larger the Sensor Field, the better the performance of the proposed method by up to 87%. The larger the sensor field, the more efficient the proposed method is over the conventional method. That is, the proposed method is suitable for the wide Sensor Field.

전력선 통신에 적합한 모뎀의 설계 및 성능평가 (Design and Performance Analysis Of the Modem for the Adapitive communication in the power line)

  • 안병록;송준호;이해기;이춘모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.62-69
    • /
    • 2003
  • In recent years, data transmission using power lines has been much highlighted. Power line is known to be cost-effective communication medium because the entire cable infrastructure has been already established and it is entirely connected with any home. Recently, the target of researches is to communicate data reliably over power lines at the speed of at least 1Mbits/s over the frequency range from 1MHz to 10MHz. OFDM communication system has been used for the high speed data transmission. Next, the conventional and adaptive OFDM systems for high speed data transmission over power line channel are investigated. The performance of AOFDM(adaptive OFDM) over the frequency selective channel with impulsive and narrow-band noise are studied to be a nice solution for high speed data transmission over power lines. The simulation results show that data the rates of the AOFDM are improved about 47% more than the ones of the conventional OFDM over the frequency response of case 4. In the results, the data rate has been much improved by the proposed adaptive algorithm in the frequency selective channel.

  • PDF

Automated Surface Wave Measurements for Evaluating the Depth of Surface-Breaking Cracks in Concrete

  • Kee, Seong-Hoon;Nam, Boohyun
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권3호
    • /
    • pp.307-321
    • /
    • 2015
  • The primary objective of this study is to investigate the feasibility of an innovative surface-mount sensor, made of a piezoelectric disc (PZT sensor), as a consistent source for surface wave velocity and transmission measurements in concrete structures. To this end, one concrete slab with lateral dimensions of 1500 by 1500 mm and a thickness of 200 mm was prepared in the laboratory. The concrete slab had a notch-type, surface-breaking crack at its center, with depths increasing from 0 to 100 mm at stepwise intervals of 10 mm. A PZT sensor was attached to the concrete surface and used to generate incident surface waves for surface wave measurements. Two accelerometers were used to measure the surface waves. Signals generated by the PZT sensors show a broad bandwidth with a center frequency around 40 kHz, and very good signal consistency in the frequency range from 0 to 100 kHz. Furthermore, repeatability of the surface wave velocity and transmission measurements is significantly improved compared to that obtained using manual impact sources. In addition, the PZT sensors are demonstrated to be effective for monitoring an actual surface-breaking crack in a concrete beam specimen subjected to various external loadings (compressive and flexural loading with stepwise increases). The findings in this study demonstrate that the surface mount sensor has great potential as a consistent source for surface wave velocity and transmission measurements for automated health monitoring of concrete structures.