• 제목/요약/키워드: Transmission Loss Coefficient

검색결과 114건 처리시간 0.019초

A New Design Approach for Asymmetric Coupled-Section Marchand Balun

  • Park, Ji An;Cho, Choon Sik;Lee, Jae Wook
    • Journal of electromagnetic engineering and science
    • /
    • 제14권2호
    • /
    • pp.54-60
    • /
    • 2014
  • A systematic design for asymmetric coupled-section Marchand baluns is presented. Asymmetrically coupled transmission lines in multilayer configuration are exploited for constructing Marchand baluns. Design equations for characteristic impedance and electrical length of asymmetrical coupled transmission lines are derived for establishing a systematic design procedure. Novel Marchand balun based on these design equations is composed of two identical asymmetrical coupled transmission lines. However, contrary to the general conventional design approach where ranges for characteristic impedances of coupled lines are ambiguously capitalized, values for characteristic impedance and length are explicitly expressed. Our approach is fundamentally different from the design method using coupling coefficients where solution for coupling coefficient is inherently restricted. To verify the proposed method, one design example is performed for wideband Marchand balun in multilayer configuration, and is fabricated for verifying the design procedure proposed. Maintaining the return loss more than 10 dB, the bandwidth is measured from 0.43 to 1.0 GHz, where $S_{21}$ and $S_{31}$ show better than -4 dB. The measured phase and amplitude imbalances illustrate 0.5 dB and ${\pm}5^{\circ}$, respectively.

Development of an Acoustic-Based Underwater Image Transmission System

  • 최영철;임영곤;박종원;김시문;김승근
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.109-114
    • /
    • 2003
  • Wireless communication systems are inevitable for efficient underwater activities. Because of the poor propagation characteristics of light and electromagnetic waves, acoustic waves are generally used for the underwater wireless communication. Although there are many kinds of information type, visual images take an essential role especially for search and identification activities. For this reason, we developed an acoustic-based underwater image transmission system under a dual use technology project supported by MOCIE (Ministry of Commerce, Industry and Energy). For the application to complicated and time-varying underwater environments all-digital transmitter and receiver systems are investigated. Array acoustic transducers are used at the receiver, which have the center frequency of 32kHz and the bandwidth of 4kHz. To improve transmission speed and quality, various algorithms and systems are used. The system design techniques will be discussed in detail including image compression/ decompression system, adaptive beam- forming, fast RLS adaptive equalizer, ${\partial}/4$ QPSK (Quadrilateral Phase Shift Keying) modulator/demodulator, and convolution coding/ Viterbi. Decoding.

  • PDF

비접촉 충전 에너지 전달을 위한 포워드형 ZVS MRC에 관한 연구 (The Study on Forward ZVS MRC for Non-contact Charging Energy Transmission)

  • 김영길;김진우;김태웅;원영진;이성백
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.64-72
    • /
    • 2001
  • 본 논문에서는 비접촉 충전 에너지 전달을 위한 포워드 ZVS MRC(Zero Voltage Switching Multi Resonant Converter)를 제안하였다. 포워드 ZVS MRC는 기생성분을 흡수하는데 그리고 스위칭손실을 최소화하는데 효과적이다. 이것은 높은 주파수동작에 적합하며 따라서 이것을 비접촉 충전에너지 전달에 적용하였다. 사용된 컨버터는 분리형 트랜스포머와 동기식정류기를 이용하였다. 갭의 크기에 따른 결합계수(k), 누설인덕턴스, 결합인 덕턴스 그리고 공진 주파수를 측정하였다. 구해진 값을 이용하여 회로를 설계, 구현하였으며 제안된 회로는 PSPICE로 시뮬레이션하였고 실험하였다. 주스위치의 전압 스트래스와 출력전력을 측정하였으며 제안된 컨버터가 비접촉 충전 에너지 전달에 적합함을 보였다.

  • PDF

진공챔버 내 프리트 이용 진공유리 봉지공정 최적화에 관한 연구 (A Study on Optimization of Vacuum Glazing Encapsulating Process using Frit inside a Vacuum Chamber)

  • 박상준;이영림
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.567-572
    • /
    • 2013
  • 냉난방을 사용하는 가정에서는 대부분 창문을 통해 열손실이 이루어지고 있는데 이를 방지하기 위해 Low-E 유리, 복층유리 또는 진공유리가 사용되고 있다. 본 논문에서는 진공유리 제작공정의 최종공정인 봉지공정에 대한 연구가 수행되었는데 기존 상압 접합이 아닌 진공챔버 내 접합이 고려되었다. 봉지과정의 효율성을 위해 진공챔버 내에서 히터온도에 따른 프리트 용융온도 및 접합시간을 최적화하였고 열응력으로 인한 유리 파손을 방지하기 위해 유리 예열온도를 최적화하였다. 이러한 결과를 바탕으로 성공적으로 진공유리를 제작하였고 측정된 열관류율은 약 $5.7W/m^2K$로 진공유리 내부압력은 약 $10^{-2}$ torr로 판명되었다.

환기팬 시스템의 소음특성과 저감에 관한 실험적 연구 (An Experimental Study on the Noise Characteristics and Reduction of a Ventilating Fan System)

  • 김덕한;이동훈;권혁정;김동윤;이종석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.500-505
    • /
    • 2005
  • This paper introduces an experimental study for the noise characteristics and reduction of a ventilating fan system. For the purpose of noise reduction of it, an absorptive duct silencer filled with a glass fiber has been conventionally utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with their sound absorption performances.

  • PDF

셀룰로오즈 흡음재의 음향적 특성 평가 (Evaluations of the Acoustics Characteristics of Cellulose Absorbers)

  • 연준오;김경우;양관섭
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.456-462
    • /
    • 2013
  • Eco-friendly material applied to building would be one of the materials which is must developed for global environmental conservation and reduction of carbon dioxide. For development of eco-friendly material, a cellulose absorber has been developed with waste paper through adjustment of various mix proportions. The developed cellulose absorber has been tested for its acoustic properties such as absorption coefficient and dynamic stiffness. The absorption coefficient was evaluated by developing six samples and using impedance tube and reverberation chamber. As a result of the evaluation, 0.64(NRC) was secured in absorption coefficient and 4.7 $MN/m^3$ was indicated in dynamic stiffness. Also, for practical use of developed absorbers as inner heartwood in drywall, comparison test of sound reduction index was performed with existing glass wool absorbers and constructed drywall of gypsum board. The results have shown 55 dB(Rw) of sound reduction index in glass-wool wall and 46 dB(Rw) in cellulose.

주택 창의 SHGC가 에너지소비에 미치는 영향에 관한 연구 (A study of Energy use Impacts by SHGCs of Windows in Detached House)

  • 박률;박종일
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.189-196
    • /
    • 2010
  • U-factor and solar heat gain coefficient(SHGC) usually can be used as the index to evaluate the thermal performance. U-factor is a concept for heat loss by the temperature difference between inside and outside, so it's useful to be applied in heating season. But SHGC that indicates the fraction of heat from incident solar radiation that flows through a window by means of optical transmission, as well as absorption, re-radiation and convection is for cooling season. In other words, U-factor and SHGC of windows by cities have to be reflected to select the window of the energy conservation. The purpose of this research is to analyze the energy use impacts by SHGCs of windows for detached house in Inchon and Ulsan through energy simulation by eQUEST.

두 가지 서로 다른 실내 복도에서 3, 6, 10, 17 GHz의 전파 특성 측정 및 비교 분석 (Measurement and Comparative Analysis of Propagation Characteristics in 3, 6, 10, and 17 GHz in Two Different Indoor Corridors)

  • 이성훈;조병록
    • 한국전자통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1031-1040
    • /
    • 2023
  • 서로 다른 두 가지 실내 복도의 D2 건물과 E2 건물 2층에서 3, 6, 10, 17 GHz 주파수 대역에 대한 가시선(: Line of sight, LOS) 경로의 전파 특성을 측정 및 분석하였다. 송신 안테나를 고정한 상태에서 수신 안테나가 3 m에서 30 m까지 0.5 m 간격으로 측정한다. 두 실내 복도에 대한 분석은 기본 전송 손실, RMS(: Root mean square) 지연 확산 및 K-인자(: K-factor)를 적용하여 비교하였다. 기본 전송 손실은 FI(: Floating intercept) 경로 손실 모델의 손실 계수에서 D2 건물 보다 E2 건물의 실내 복도에서 더 높게 나타났다. 마찬가지로, 시간 영역에서 RMS 지연 확산이 E2 건물의 실내 복도에서 더 크다. 그러나 D2 건물의 실내 복도에서는 3, 6, 17 GHz 대역에서 더 높은 K-인자값을 나타냈고, 10 GHz 대역에서는 전파 전달도가 더 낮은 것으로 나타났다. 두 가지 실내 복도는 동일한 크기에도 불구하고 내부 구조와 재질이 다르기 때문에 전파 특성의 변화가 많다. 결과는 다양한 실내 환경에 대한 ITU-R 기고에 대한 측정 데이터를 제공한다.

접수 구조물의 연성손실계수 변화에 관한 연구 (A Study on the Characteristics of Coupling Loss factor Associated with Fluid Loading)

  • 류정수
    • 한국음향학회지
    • /
    • 제19권6호
    • /
    • pp.17-22
    • /
    • 2000
  • 항공기나 선박과 같은 복잡한 구조물의 광대역 진동, 소음 예측을 위해 통계에너지해석법(SEA)이 널리 이용되고 있다. SEA를 이용해 접수 구조물의 진동, 소음을 정확히 해석하기 위해서는 접수에 의한 각 파라메터의 변화를 알아야만 한다. 본 연구에서는 기본 결합 요소인 'L'형과 'T'형 선결합 구조물에서 접수를 고려한 연성손실계수를 해석하고 공기중 진동시의 해석 결과와 비교하였다. 또한 'L'형, 'T'형 선결합을 가지는 단순한 형상의 steel box가 수중에서 진동하는 경우에, 접수에 의한 연성손실계수 변화가 세부시스템의 진동에 미치는 영향을 살펴보았다. 이를 통해, 구조물이 접수될 때 발생하는 연성손실계수의 변화를 확인하였으며, SEA를 이용한 접수 구조물의 진동 및 소음 해석시 결과의 신뢰성을 높이기 위해서는 접수에 의한 모드밀도, 내부손실계수 변화와 더불어 접수에 의한 연성손실계수 변화를 반드시 고려하여야 함을 확인하였다.

  • PDF

원통형 임피던스 튜브 내 다중 미세천공 판의 음향투과 (Sound transmission of multi-layered micro-perforated plates in a cylindrical impedance tube)

  • 김현실;마평식;김봉기;이성현;서윤호
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.270-278
    • /
    • 2020
  • 본 논문은 원통형 임피던스 튜브내에 설치된 다중 미세천공판(Micro-Perforated Plate, MPP)의 음향투과를 해석적으로 구하는 방법을 다루었다. 판의 진동을 무한 급수의 합으로 전개하였는데 반경방향으로는 Bessel 함수를 포함한다. 평면파 가정하에서 저주파수 대역의 근사식을 유도하였으며 전달함수법을 이용하여 다중 MPP에 대한 음향투과율 공식을 제시하였다. 단일과 이중 MPP의 음향투과손실(Sound Transmission Loss, STL)을 본 논문에서 제안한 공식을 이용하여 계산하였으며 유한요소법(Finite Element Method, FEM)을 사용한 결과와 잘 일치 하였다. 천공율이 증가할수록 STL은 감소하는데 이는 판의 진동보다는 천공율이 더 큰 영향을 주기 때문이다. STL은 판의 공진주파수에서 골(dip)을 보이며 이중 MPP의 STL은 질량-스프링-질량 진동에 해당하는 공진주파수에서 골을 보인다. 본 연구에서 제안한 STL 예측 모델은 임의의 개수의 다중 MPP에 적용이 가능하며 각각의 판은 미세천공을 포함하거나 포함하지 않는 두 가지 경우가 모두 가능하다.