• 제목/요약/키워드: Transmission Line Method

검색결과 1,065건 처리시간 0.03초

송전선로 활선작업용 도전복 기술 및 적용현황 (Conductive Clothing Techniques and Application Status To Live Line Works in T/L)

  • 이형권;한형주;방항권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2123_2124
    • /
    • 2009
  • Nowadays live-line work is a general maintenance method in most countries. After 765kV transmission lines constructed, necessity of the live line work is on the rise, due to maintenance problems. During live line working, a line man must wear the conductive clothing for protection from electrical fields and shocks. This paper suggests about design technology and application status of a conductive clothing to live works, before developing the clothing in detail.

  • PDF

병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘 (The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line)

  • 이재규;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

X-대역에서의 Foam 재료의 복소 유전율 (Complex Permittivity of Foam Materials at X-Band)

  • 방재훈;안병철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.72-75
    • /
    • 2000
  • This paper investigates the complex permittivity of foam materials using the rectangular waveguide. The transmission coefficients of materials inserted in the waveguide are measured with a network analyzer and calculated from the equivalent transmission line model. We use the trial and error method in the acquisition of the complex permittivity.

  • PDF

Investigation on the failure type of tower segments under equivalent static wind loads

  • Li, Yue;Xie, Qiang;Yang, Zheng
    • Wind and Structures
    • /
    • 제34권2호
    • /
    • pp.161-171
    • /
    • 2022
  • This paper presents a failure type assessment curve method to judge the failure type of transmission tower segments. This novel method considers the equivalent static wind load characteristics and the transmission tower members' load-bearing capacities based on numerical simulations. This method can help judge the failure types according to the relative positions between the actual state points and the assessment curves of transmission tower segments. If the extended line of the actual state point intersects with the horizontal part's assessment curve, the segment would lose load-bearing capacity due to the diagonal members' failure. Another scenario occurs when the intersection point is in the oblique part, indicating that the broken main members have caused the tower segment to fail. The proposed method is verified by practical engineering case studies and static tests on the scaled tower segments.

HVDC시스템 적용을 위한 Triple-tuned 필터 설계방법 연구 (A Study on the Design of Triple-tuned Filter for Line Commutated Converter HVDC)

  • 이성두;최순호;김찬기;차한주
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1288-1296
    • /
    • 2015
  • The ac side current of a line commutated converter(LCC) high voltage direct current (HVDC) is characterized by highly non-sinusoidal waveform. If the harmonic current is allowed to flow in the connected ac network, it may cause unacceptable levels of distortion. Therefore, ac side filters are required as part of the total HVDC converter station, in order to reduce the harmonic distortion of the ac side current and voltage to acceptably low levels. The ac filters are also employed to compensate the requested reactive power because LCC HVDC also consume substantial reactive power. Among different types of filters, triple-tuned filters have been widely utilized for HVDC system. This paper presents two design methods of triple-tuned filter; equivalent method and parametric method. Using a parametric method, in particular this paper proposes a design algorithm for a triple tuned filter. Finally, the performance of the design algorithm is evaluated for a 250kV HVDC system in Jeju island. The results cleary demonstrate the effectiveness of proposed design method in harmonics reduction.

765kV 2회선 송전선 활선 작업자의 차폐복 자계저감 특성검토 (Magnetic Field Reduction Characteristics of Hot-Line Worker's Shielding Wear for 765kV Double Circuit Transmission Line)

  • 민석원;박준형
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1632-1637
    • /
    • 2007
  • This paper analyses current densities induced inside human body of lineman for 765kV transmission line when he wears a protective cloth or not. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 15[cm], 30[cm], 50[cm], and 100[cm] far from a prefabricated jumper. As results of study, we find a maximum current density induced in all organs may be higher than $10[mA/m^2]$ if he does not wear protective clothes. We also know high permeability materials can lower current density more than high conductivity materials.

비선형 분산안전법을 이용한 최적장기송전계률 알고리 (Optimal Long-term Transmission Planning Algorithm using Non-linear Branch-and-bound Method)

  • 박영문;신중린
    • 대한전기학회논문지
    • /
    • 제37권5호
    • /
    • pp.272-281
    • /
    • 1988
  • The problem of optimal transmission system planning is to find the most economical locations and time of transmission line construction under the various constraints such as available rights-of-way, finances, the technical characteristics of power system, and the reliability criterion of power supply, and so on. In this paper the constraint of right-of-way is represented as a finite set of available rights-of-way. And the constructed for a unit period. The electrical constraints are represented in terms of line overload and steady state stability margin. And the reliability criterion is dealt with the suppression of failure cost and with single-contingency analysis. In general, the transmission planning problem requires integer solutions and its objective function is nonlinear. In this paper the objective function is defined as a sum of the present values of construction cost and the minimum operating cost of power system. The latter is represented as a sum of generation cost and failure cost considering the change of yearly load, economic dispatch, and the line contingency. For the calculation of operating cost linear programming is adopted on the base of DC load flow calculation, and for the optimization of main objective function nonlinear Branch-and-Bound algorithm is used. Finally, for improving the efficiency of B & B algorithm a new sensitivity analysis algorithm is proposed.

손실배분계수를 이용한 송전선로 유효전력 손실의 배분법 (A Method to Allocate Real Power Losses of Transmission Lines using Loss Distribution factors)

  • 노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1259-1261
    • /
    • 1999
  • The paper proposes a simple method to calculate the portion of real power losses allocated to individual loads. The method is implemented by loss distribution factors, and analyses the share of loads in transmission line losses. Effectiveness of the algorithm is verified by a computer simulation. The results can be used to compute the cost of ancillary services under deregulated environment in electric power industries.

  • PDF

Harmonic Distortion Contribution for the Transmission Loss Allocation in Deregulated Energy Market: A New Scheme for Industry Consumer

  • Nojeng, Syarifuddin;Hassan, Mohammad Yusri;Said, Dalila Mat;Abdullah, Md.Pauzi;Hussin, Faridah
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 2015
  • The industry has rapidly growth and energy supply technology advanced are become main factor which to contribute of the harmonic losses. This problem is one aspect that may affect the capability of the transmission line and also to the efficiency of electricity. This paper proposes a new scheme to allocate the cost pertaining to transmission loss due to harmonics. The proposed method, called as Generalized Harmonic Distribution Factor, uses the principle of proportional sharing method to allocate the losses among the transmission users especially for industry consumers. The IEEE 14- and 30 bus test system is used to compare the proposed method with existing method. The results showed that the proposed method provided a scheme better in allocating the cost of transmission loss, which could encourage the users to minimize the losses.

헬름홀츠 공명기들로 구성된 음향 메타물질의 파동전파 특성 (Wave Propagation Characteristics of Acoustic Metamaterials with Helmholtz Resonators)

  • 권병진;조충희;박광춘;오일권
    • 한국소음진동공학회논문집
    • /
    • 제23권2호
    • /
    • pp.167-175
    • /
    • 2013
  • The wave propagation characteristics of an acoustic metamaterial composed of periodically repeated one-dimensional Helmholtz resonator array was investigated considering the effects of dimensional changes of the resonator geometry on the transmission coefficient and band gap. The effective impedance and transmission coefficient of the acoustic metamaterials are obtained based on the acoustic transmission line method. The designed acoustic metamaterials exhibit band gaps and negative bulk modulus that are non-existent properties in the nature. The band gap of the acoustic metamaterial is strongly dependent on the geometry parameters of Helmholtz resonators and lattice spacing. Also, a new type of metamaterial that is periodically constructed with two different resonators was designed to open the local resonance band gap without change of Bragg scattering.