• 제목/요약/키워드: Translucent zirconia

검색결과 31건 처리시간 0.025초

Comparative analysis of transmittance for different types of commercially available zirconia and lithium disilicate materials

  • Harianawala, Husain Hatim;Kheur, Mohit Gurunath;Apte, Sanjay Krishnaji;Kale, Bharat Bhanudas;Sethi, Tania Sanjeev;Kheur, Supriya Mohit
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.456-461
    • /
    • 2014
  • PURPOSE. Translucency and colour stability are two most important aspects for an aesthetic dental restoration. Glass ceramic restorations are popular amongst clinicians because of their superior aesthetic properties. In the last decade, zirconia has generated tremendous interest due to its favorable mechanical and biological properties. However, zirconia lacks the translucency that lithium disilicate materials possess and therefore has limitations in its use, especially in esthetically demanding situations. There has been a great thrust in research towards developing translucent zirconia materials for dental restorations. The objective of the study was to evaluate and compare the transmittance of a translucent variant of zirconia to lithium disilicate. MATERIALS AND METHODS. Two commercially available zirconia materials (conventional and high translucency) and 2 lithium disilicate materials (conventional and high translucency) with standardized dimensions were fabricated. Transmittance values were measured for all samples followed by a microstructural analysis using a finite element scanning electron microscope. One way analysis of variance combined with a Tukey-post hoc test was used to analyze the data obtained (P=.05). RESULTS. High translucency lithium disilicate showed highest transmittance of all materials studied, followed by conventional lithium disilicate, high translucency zirconia and conventional zirconia. The difference between all groups of materials was statistically significant. The transmittance of the different materials correlated to their microstructure analysis. CONCLUSION. Despite manufacturers' efforts to make zirconia significantly more translucent, the transmittance values of these materials still do not match conventional lithium disilicate. More research is required on zirconia towards making the material more translucent for its potential use as esthetic monolithic restoration.

Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses

  • Chonticha Subsomboon;Somchai Urapepon
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권4호
    • /
    • pp.171-178
    • /
    • 2023
  • PURPOSE. The purpose of this study was to determine the effect of the connector configuration on the fracture load in conventional and translucent zirconia of three-unit fixed dental prostheses (FDPs). MATERIALS AND METHODS. Six different three-unit FDPs were prepared (n = 6) from three types of zirconia (3Y-TZP (Katana ML®), 4Y-TZP (Katana STML®), and 5Y-TZP (Katana UTML®)) in combination with two connector configurations (4 × 2.25, 3 × 3 mm). The CoCr master models were scanned, and the FDPs were designed and fabricated using CAD-CAM. The FDPs were cemented on the metal model and then loaded with a UTM at a crosshead speed of 1 mm/min until failure. Two-way ANOVA and Tukey's test were used for statistical analysis (α = .05). RESULTS. Fracture loads of 3Y-TZP (2740.6 ± 469.2 and 2718.7 ± 339.0 N for size 4 × 2.25 mm and 3 × 3 mm, respectively) were significantly higher than those of 4Y-TZP (1868.3 ± 281.6 and 1663.6 ± 372.7 N, respectively) and 5Y-TZP (1588.0 ± 255.0 and 1559.1 ± 110.0 N, respectively) (P < .05). No significant difference was found between fracture loads of 4Y-TZP and 5Y-TZP (P > .05). The connector configuration within 9 mm2 was found to have no effect on the fracture loads on all three types of zirconia (P > .05). CONCLUSION. Fracture loads of three-unit FDPs were affected by the type of zirconia. The fracture loads of conventional zirconia were higher than those of translucent zirconia. However, it was not affected by the connector configuration when the connector had a cross-sectional area of 9 mm2.

심미수복용 기성 지르코니아 크라운의 색조 평가 (Colorimetric Analysis of Preformed Zirconia Anterior Crowns for Esthetic Restoration)

  • 이창근;박기봉;양연미;이대우;김재곤
    • 대한소아치과학회지
    • /
    • 제46권3호
    • /
    • pp.318-327
    • /
    • 2019
  • 이 연구의 목적은 지르코니아 크라운의 종류 및 두께와 시멘트 종류에 따른 색조를 평가하여 상악 유중절치와 가장 유사한 조합을 확인하는 것이었다. 시중에 유통되는 3가지 색조의 기성 지르코니아 크라운과 6종류의 지르코니아 블럭을 이용해 제작한 크라운이 연구에 사용되었고, A2 shade 또는 translucent shade의 레진 시멘트로 크라운 내면을 충전하였다. 분광 광도계를 이용하여 각 시편의 $L^*$, $a^*$, $b^*$ 값을 평가하여, 자연치와 지르코니아 크라운의 색 차이(ΔEn)를 평가하였다. 시편의 색조는 translucent-shade 레진시멘트를 사용했을 때 보다 A2-shade 레진시멘트를 사용하였을 때 더욱 자연치와 유사하였고, smile series 2 (SmS2) 지르코니아 블록으로 0.5 mm 두께의 크라운을 제작하여 A2-shade 레진시멘트로 채웠을 때 가장 자연치와 색 차이가 가장 작았다. 한국 어린이들의 상악 유전치부를 지르코니아 크라운으로 수복할 때, translucent-shade의 레진시멘트 보다는 A2-shade의 레진시멘트를 사용하는 것이 권장되고, 기성 지르코니아 크라운은 색조면에서 심미성이 충분하지 못하기 때문에 기성 지르코니아 크라운의 색조 개선이나 새로운 종류의 지르코니아 크라운의 개발이 필요하다.

Microhardness of resin cements after light activation through various translucencies of monolithic zirconia

  • Pechteewang, Sawanya;Salimee, Prarom
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권4호
    • /
    • pp.246-257
    • /
    • 2021
  • PURPOSE. This study aimed to investigate the Vickers Hardness Number (VHN) of light- and dual cured resin cements cured through monolithic zirconia specimens (VITA YZ) of various translucencies: translucent (T); high translucent (HT); super translucent (ST); and extra translucent (XT) at 0, 24, and 48 h after curing. MATERIALS AND METHODS. Four zirconia specimens from each translucency were prepared. Two light-cured resin cements (Variolink N LC; VL and RelyX Veneer; RL) and two dual-cured resin cements (Variolink N DC; VD and RelyX U200; RD) were used. The cement was mixed and loaded in a mold and cured for 20 s through the zirconia specimen. The upper surface of cements was tested for VHN using a microhardness tester at 0, 24, and 48 h after curing. The VHN were analyzed using two-way repeated, Brown-Forsythe ANOVA with Games Howell post-hoc analysis and independent t-tests (P < .05). RESULTS. All cements showed significantly higher VHN from 0 h to 24 h (P < .001). At 48 h, the VHN of light-cured cements were significantly lower when cured under the T groups than under XT groups (P = .001 in VL, P = .014 in RL). At each post curing time of each translucency, VD showed higher VHN than VL (P < .05), and RD also showed higher VHN than RL (P < .05). CONCLUSION. The translucency of zirconia has an effect on the VHN for light-cured resin cements, but has no effect on dual-cured resin cements. Dual-cured resin cement exhibited higher VHN than the light-cured resin cement from the same manufacturer. All resin cements showed significantly higher VHN from 0 h to 24 h.

Translucency and masking ability of translucent zirconia; comparison with conventional zirconia and lithium disilicate

  • Park, Joon Hee;Bang, Hyun Ji;Choi, Nak-Hyun;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권5호
    • /
    • pp.324-333
    • /
    • 2022
  • PURPOSE. The purpose of this study is to evaluate translucency and masking ability of translucent zirconia compared to conventional zirconia and lithium disilicate materials. MATERIALS AND METHODS. Three types of zirconia blocks with different yttria contents (3Y, 4Y, 5.5Y) and LS blocks (Rosetta SM) were used. Ten specimens for each group were fabricated with 10 mm diameter, with both 0.8 mm and 1.5 mm thicknesses (± 0.02 mm). All groups of zirconia specimens were sintered and polished according to the manufacturer's instructions. To calculate the translucency parameter (TP), CIELAB value was measured with a spectrophotometer on black and white backgrounds. To investigate the color masking abilities, background shades of A2, normal dentin, discolored dentin, and titanium were used. The color difference (ΔE) was calculated with the CIELAB values of A2 shade background as a reference compared with the values in the various backgrounds. One-way ANOVA and Bonferroni tests were conducted (P < .05). RESULTS. The TP values of zirconia specimens increased as the yttria content increased. All materials used in the study were able to adequately mask normal dentin shade (ΔE < 5.5), but were incapable of masking severely discolored dentin (ΔE > 5.5). On the titanium background, all materials of 1.5 mm thickness were able to mask the background shade, but with a thickness of 0.8 mm, only 3Y-TZP and 4Y-PSZ were able to mask titanium background. CONCLUSION. All zirconia materials and lithium disilicate specimens used in this study were unable to adequately mask the shade of severely discolored dentin. It is recommended to use 3Y-TZP or 4Y-PSZ with a sufficient thickness of 0.8 mm or more to mask titanium.

Comparison of the translucency of shaded zirconia all-ceramic systems

  • Kurtulmus-Yilmaz, Sevcan;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.415-422
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate and compare the translucency of shaded zirconia allceramic systems. MATERIALS AND METHODS. Translucency of 3 different zirconia all-ceramic systems colored by different techniques was compared with a lithium disilicate glass-ceramic (IPS e.max Press). Square-shaped specimens with 0.5 mm thickness were fabricated from In-Ceram YZ, ICE Zirkon and Katana systems in A1, A2 and A3.5 shades according to Vitapan Classical shade tab (n=11). Specimens were then veneered and glazed with corresponding veneer ceramic recommended by each zirconia system manufacturer and the total thickness was set to 1.5 mm. Translucency measurements were performed with VITA Easyshade Compact spectrophotometer after each stage and translucency parameter was calculated. Data were statistically analyzed with repeated measures ANOVA and Tukey multiple comparison test. RESULTS. The control group was significantly more translucent than the zirconia systems (P<.05). ICE Zirkon cores showed the least translucency; neither In-Ceram YZ nor Katana systems were superior to each other in terms of translucency. Translucency of all specimens was decreased after veneering, and the translucency rankings were changed. CONCLUSION. Coloring technique did not have a significant effect on translucency of zirconia cores. Although zirconia systems were less translucent than lithium disilicate glass ceramic, they had partial translucency and there were translucency differences among the zirconia systems. Chroma affected the translucency of precolored zirconia cores.

Influence of preparation design on fracture resistance of different monolithic zirconia crowns: A comparative study

  • Findakly, Meelad Basil;Jasim, Haider Hasan
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.324-330
    • /
    • 2019
  • PURPOSE. The aim of the study was to evaluate and compare the fracture resistance and modes of fracture of monolithic zirconia crowns with two preparation designs. MATERIALS AND METHODS. Forty human maxillary first premolar teeth were extracted for orthodontic purposes and divided into two main groups (n=20): Group A: monolithic traditional zirconia; Group B: monolithic translucent zirconia. The groups were further subdivided into two subgroups (n=10): (A1, B1) shoulder margin design; (A2, B2) feather-edge margin design. Teeth were prepared with either a 1 mm shoulder margin design or a feather-edge margin design. The prepared teeth were scanned using a digital intraoral scanner. The crowns were cemented using self-adhesive resin cement. All cemented teeth were stored in water for 7 days and thermocycling was done before testing. All samples were subjected to compressive axial loading until fracture. The fractographic analysis was done to assess the modes of fracture of the tested samples. RESULTS. The highest mean values of fracture resistance were recorded in kilo-newton and were in the order of subgroup A1 (2.903); subgroup A2 (2.3); subgroup B1 (1.854) and subgroup B2 (1.523). One-way ANOVA showed a statistically significant difference among the 4 subgroups. Concerning modes of fracture, the majority of samples in subgroups A1 and B1 were fracture of restoration and/or tooth, while in subgroups A2 and B2, the majority of samples fractured through the central fossa. CONCLUSION. Even though all the tested crowns fractured at a higher level than the maximum occlusal forces, the shoulder margin design was better than the feather-edge margin design and the monolithic traditional zirconia was better than the monolithic translucent zirconia in terms of fracture strength.

Influence of heat treatment on the microstructure and the physical and mechanical properties of dental highly translucent zirconia

  • Dimitriadis, Konstantinos;Sfikas, Athanasios Konstantinou;Kamnis, Spyros;Tsolka, Pepie;Agathopoulos, Simeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.96-107
    • /
    • 2022
  • PURPOSE. Microstructural and physico-mechanical characterization of highly translucent zirconia, prepared by milling technology (CAD-CAM) and repeated firing cycles, was the main aim of this in vitro study. MATERIALS AND METHODS. Two groups of samples of two commercial highly-translucent yttria-stabilized dental zirconia, VITA YZ-HTWhite (Group A) and Zolid HT + White (Group B), with dimensions according to the ISO 6872 "Dentistry - Ceramic materials", were prepared. The specimens of each group were divided into two subgroups. The specimens of the first subgroups (Group A1 and Group B1) were merely the sintered specimens. The specimens of the second subgroups (Group A2 and Group B2) were subjected to 4 heat treatment cycles. The microstructural features (microstructure, density, grain size, crystalline phases, and crystallite size) and four mechanical properties (flexural strength, modulus of elasticity, Vickers hardness, and fracture toughness) of the subgroups (i.e. before and after heat treatment) were compared. The statistical significance between the subgroups (A1/A2, and B1/B2) was evaluated by the t-test. In all tests, P values smaller than 5% were considered statistically significant. RESULTS. A homogenous microstructure, with no residual porosity and grains sized between 500 and 450 nm for group A and B, respectively, was observed. Crystalline yttria-stabilized tetragonal zirconia was exclusively registered in the X-ray diffractograms. The mechanical properties decreased after the heat treatment procedure, but the differences were not statistically significant. CONCLUSION. The produced zirconia ceramic materials can be safely (i.e., according to the ISO 6872) used in extensive fixed prosthetic restorations, such as substructure ceramics for three-unit prostheses involving the molar restoration and substructure ceramics for prostheses involving four or more units. Consequently, milling technology is an effective manufacturing technology for producing zirconia substructures for dental fixed all-ceramic prosthetic restorations.

고반투명 유색 지르코니아의 굽힘강도와 신뢰도에 대한 연구 (Flexural strength and reliability of highly translucent colored zirconia)

  • 공현준
    • 구강회복응용과학지
    • /
    • 제36권1호
    • /
    • pp.41-47
    • /
    • 2020
  • 목적: 본 연구의 목적은 전부도재 수복물을 위해 단일체로 사용되는 고반투명 유색 지르코니아의 굽힘강도 및 신뢰도를 평가하기 위함이다. 연구 재료 및 방법: 전부도재 수복물을 위해 사용되는 무색(A0) 및 유색(A1, A3)의 고반투명 지르코니아 블록을 사용하여 바 형태의 시편(25 × 4 × 2.5 mm)을 제작하였다. 지르코니아 블록의 색조에 따라 3개의 실험군을 설정하였고, 한 군당 20개의 시편을 제작하였다. 굽힘강도는 3점 굽힘시험을 통해 측정하였으며, 일원배치 분산분석을 이용하여 색조에 따른 통계적 유의성을 검증하였다. 다음으로 세라믹 재료 특성상 신뢰도를 평가하기 위해 와이블 분석을 시행하였으며, X선 회절분석으로 시편의 결정특성을 분석하였다. 결과: 무색 고반투명 지르코니아의 굽힘강도(1127.10 MPa)가 색조 A1 (995.71 MPa)과 A3 (1016.42 MPa)에 비해 통계학적으로 유의하게 높은 값을 보였다(P < 0.05). 색조 A1과 A3 사이에는 유의한 차이가 없었다(P > 0.05). 와이블 분석을 시행한 결과, 무색 고반투명 지르코니아가 유색에 비해 높은 신뢰도를 나타냈다. X선 회절분석 결과 모든 그룹에서 지르코니아 정방정상의 특징적인 피크를 보였다. 결론: 본 제한된 연구의 결과를 근거로 단일체로 사용되는 고반투명 지르코니아에 색조를 가미하는 것이 굽힘강도와 신뢰도를 저하시킬 수 있으며, 도재 파절을 방지하고 심미 증진을 위해 고반투명 지르코니아를 사용할 경우 색조 선택에 주의를 기울여야 할 것이다.

반투명 지르코니아와 리튬디실리케이트 결정화유리의 물성에 관한 문헌고찰 (Properties of translucent zirconia and lithium disilicate glass-ceramics: a literature review)

  • 차민상;김예진;고경호;박찬진;조리라;허윤혁
    • 구강회복응용과학지
    • /
    • 제38권2호
    • /
    • pp.71-80
    • /
    • 2022
  • 다양한 치과용 도재가 개발되고 있으나 현재 단일구조 보철물로 사용할 수 있는 수준의 기계적, 광학적 성질을 보이는 도재는 반투명 지르코니아와 리튬디실리케이트 결정화유리가 대표적이다. 기계적 성질의 경우 지르코니아가, 광학적 성질은 리튬디실리케이트가 상대적으로 더 우수하다고 알려져 있으나 물성개선을 통해 보다 다양한 증례에 보철물을 적용할 수 있게 되었다. 그 결과 반투명 지르코니아와 리튬디실리케이트 보철물의 적응증이 서로 중복되는 경우가 발생하고 있다. 그러나 두 도재는 유리질(glass matrix) 포함여부뿐만 아니라 강화기전, 탄성계수 등이 서로다르다. 이에 본 문헌고찰에서는 두 단일구조 치과용 도재의 물성을 평가한 다양한 연구결과들을 살펴보고 특히 가공치가 포함된 고정성 보철물의 디자인 시 고려사항에 대해 알아보고자 한다.