• Title/Summary/Keyword: Transient stability analysis

Search Result 297, Processing Time 0.029 seconds

A Study on the Dynamic Stability of Heavy Press Considering Rotational Speed (회전 속도를 고려한 대형 프레스의 동적 안정성에 관한 연구)

  • Shin, Min Jae;Kim, Chae Sil;Keum, Chang Min;Kim, Jae Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.8
    • /
    • pp.623-628
    • /
    • 2016
  • This article describes the determination of the dynamic stability for a heavy press, particularly considering rotational speed. A finite element model of the driving parts for the heavy press was generated. We also applied boundary conditions and dynamic loads considering the driving conditions. Modal analysis was conducted using the finite element construction model. Therefore, no resonance was identified with the comparison between the results of the modal analysis and vibration excitation frequency by the gear tooth. In addition, the stress distribution of the driving parts for press was determined using transient analysis. As compared to the yield strength of the material, the dynamic stability the heavy press was confirmed.

Coordinated Control Strategy for Power Systems with Wind Farms Integration Based on Phase-plane Trajectory

  • Zeng, Yuan;Yang, Yang;Qin, Chao;Chang, Jiangtao;Zhang, Jian;Tu, Jingzhe
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • The dynamic characteristics of power systems become more and more complex because of the integration of large-scale wind power, which needs appropriate control strategy to guarantee stable operation. With wide area measurement system(WAMS) creating conditions for realizing realt-ime transient stability analysis, a new coordinated control strategy for power system transient stability control based on phase-plane trajectory was proposed. When the outputs of the wind farms change, the proposed control method is capable of selecting optimal generators to balance the deviation of wind power and prevent transient instability. With small disturbance on the base operating point, the coordinated sensitivity of each synchronous generator is obtained. Then the priority matrix can be formed by sorting the coordinated sensitivity in ascending order. Based on the real-time output change of wind farm, coordinated generators can be selected to accomplish the coordinated control with wind farms. The results in New England 10-genrator 39-bus system validate the effectiveness and superiority of the proposed coordinated control strategy.

Power System Analysis using OODB (객체지향 데이터베이스를 이용한 전력계통 해석)

  • 박지호;백용식
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.5
    • /
    • pp.257-265
    • /
    • 2004
  • The complex documentation involved in power system analysis software require a well-defined and friendly database system. We have developed an object-oriented database management system for power system analysis, and have described load flow analysis and transient stability analysis using object-oriented database(OODB). Database management systems are widely used and achieve high reliability of data management in the engineering fields. However relational database system have shortcomings in application to power system analysis. ill relational database, the data model is too simple for modeling complex data and database languages are very different from programming languages. Object-oriented techniques are sufficiently powerful to support data-modeling requirements of GUI applications. The GUI is implemented using C++ on a MS windows platform. The OODB supports data modeling requirements of GUI applications and the performance is well acceptable for Gill applications.

A Study on the Shock Analysis of Large Scale Antenna (대형 안테나의 충격해석에 관한 연구)

  • Shin, Geon-Ho;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.26-32
    • /
    • 2021
  • The antenna is mounted on the vehicle and operated, so its components must be able to withstand the shock that may occur while driving. In this study, the stability of antenna mounted on the vehicle is verified through the connection between modal analysis and transient analysis. The shock data used was taken from MIL-STD-810H, METHOD 516.8. As a result of the analysis of antenna, the maximum equivalent stress 169.49MPa and minimum margin of safety 2.31 has occurred on the bracket of antenna. Thus, it was found that the antenna has enough stability during the operation.

Transient State Analysis of Network Connected to Wind Generation System (풍력발전시스템이 연계된 계통의 과도상태해석)

  • Kim, Se-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.29-35
    • /
    • 2003
  • Generator for wind power can be either synchronous or asynchronous (induction) types. Induction and synchronous generators behave in a different way when subjected to severe faults. Induction generators does not have an angle stability limit and short circuit in the neighborhood of an Induction generator causes the demagnetization of the machine when the fault is cleared, the voltage raises slowly, while the grid contributes with reactive power to the generator and the magnetic flux recovers. On the other hand in the synchronous generators the recovery of the voltage is immediate, since the excitation of the rotor angle comes from an independent circuit. This paper shows the result of the transient state analysis in the network connected to wind generation system Several case studies have been conducted to determine the effect of the clearing time of a fault on the network stability. It has been found that the critical clearing time can be as low as 61ms in the case of induction generator compared to 370ms in the case of synchronous generator.

Power System Stability Analysis Considering Dynamic Loads (동적 부하를 고려한 전력계통의 On-Line 안정도 해석)

  • Seo, Gyu-Seok;Park, Ji-Ho;Kwon, Ki-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4146-4151
    • /
    • 2012
  • In this paper, we have simulated the transient stability of power system with dynamic loads. Dynamic load characteristics have an important influence on power system stability. In study of power system stability, motors form a major portion of the system loads. Induction motors and synchronous motors in particular form the workhorse of the electric power industry. Therefore modelling of motors is important in system stability. We investigate the effect of motors loads of Kwang Yang network with three phase fault.

The Merger of Transient Stability Analysis Program for dynamic models (다이나믹 모델의 과도 안정도 해석 프로그램 통합)

  • Sim Gyu Sang;Cho Yoon Sung;Jang Gil Soo;Lee Byong Jun;Kwon Sae Hyuk
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.239-241
    • /
    • 2004
  • The purpose of this paper is to explain techniques achieved while developing a transient stability program which is suitable to Korean power system. It concentrates on the development of a synchronous machine model, exciter models and turbine-governor models used in large-scale power system stability analysis. These proposed models enhance the performance of the developing program. This developing program has been tested with the KEPCO system, and the simulation results obtained from the program are compared to those of commercial programs.

  • PDF

Seepage analysis of agricultural reservoir due to raising embankment (농업용 저수지 둑 높이기에 따른 제체의 침투류 해석)

  • Lee, Dal-Won;Lee, Kwang-Sol;Lee, Young-Hak
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.493-504
    • /
    • 2011
  • This study was carried out to safety evaluation, the practical application and improvement of design method of the agricultural reservoir due to raising embankments. Also, it was to compare and analyze the pore water pressure (PWP), seepage (leakage) quantity and piping phenomenon according to high water table and rapid drawdown. The seepage analysis by finite element analysis was used for steady state and transient condition. The pore water pressure distribution for steady state and transient condition showed positive(+) PWP on the upstream slope, it was gradually changed negative(-) PWP on the downstream slope. The PWP in the core ranged from 100 ~ -33 kPa, the seepage line in the incline-type core suddenly decreased towards the lower levels from the higher levels. The PWP according to rapid drawdown is remained in the vicinity of the upstream slope, therefore, it is investigated to be in an unstable state by the slope stability analysis. The PWP after raising embankments showed smaller than in the before raising embankments. It was likely to be the piping phenomenon because the gradients in the before raising embankments showed largely at downstream slope, and the stability for piping in the after raising embankments increased stable state. The seepage quantity per 1 day and the leakage per 100m for the steady state and transient condition appeared to be safe against the piping. It reduced slightly regardless of the transient condition before the raising embankments and it decreased largely about 2.4 times in the early days after the raising embankments.

The Stability Assessment of The Critical Transmission Line using CCT (CCT 변화를 이용한 중요선로의 안정도 평가)

  • Kim, Jong-Bo;Lee, Jong-Seock;Lee, Byung-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.157-160
    • /
    • 2002
  • Power system stability assessment is a major requirement for safe operation of a power system. When the disturbance occurs, the power system transient stability is defined as the operating condition can return to steady state with getting over it. According to the system structure and the operating conditions. system instability is revealed in various shape. And as we know the result of transient stability analysis depends on the system load. In this paper, we've tried to know how much CCT is influenced as the system load changes. Therefore, comparing with CCT we can calculate the Pm that we can generate more in stable state.

  • PDF

A Study on the Effect of the Toe Geometry on the Directional Stability of Mini-bus Vehicle (토우 궤적 변화에 의한 미니 버스 차량의 방향 안정성 연구)

  • 이희범;안찬우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.4
    • /
    • pp.160-165
    • /
    • 1998
  • In this paper, We discuss the directional stability of a Mini-bus with varying suspension design parameters. We analyzed the vehicle behavior during the cornering in a transient steering condition. We made a vehicle model by use of DADS, which is dynamic analysis software, in order to carry out many cases of simulation with varying design parameters. The effect of toe-geometry change to vehicle stability is evaluated by computer simulation and the actual test. In order to reduce the under steer characteristics of a mini-bus, the amount of toe geometry change should be less than current value.

  • PDF