• Title/Summary/Keyword: Transient stability analysis

Search Result 297, Processing Time 0.033 seconds

A Study on the Thermal Behavior Characteristic of Drum Brake considering Braking Patterns (제동 패턴을 고려한 드럼 브레이크의 열적 거동 특성에 대한 연구)

  • Lee, Kye-Sub;Son, Sung-Soo;Yang, Ki-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.145-154
    • /
    • 2006
  • Each part of drum brake system is loaded by continual mechanical force and thermal force every time of braking, so enough strength and stability are required. Thermal characteristic is one of the important factors in drum brake systems design. This paper presents the thermal performance such as temperature distribution and thermal contact stress of drum brake system considering several braking patterns; 80th heat braking test mode, heat fade braking test mode, general road mode, steep slope road mode and off road mode. Transient heat transfer analysis and Thermo elastic contact analysis is executed to obtain the temperature distribution, and to evaluate thermal stress of drum brake by using ABAQUS/Standard code. This procedure of analysis can effectively be used to improve the quality problem of brake system and to get design guideline of the new product.

Critical Short Circuit Ratio Analysis on DFIG Wind Farm with Vector Power Control and Synchronized Control

  • Hong, Min;Xin, Huanhai;Liu, Weidong;Xu, Qian;Zheng, Taiying;Gan, Deqiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.320-328
    • /
    • 2016
  • The introduction of renewable energy sources into the AC grid can change and weaken the strength of the grid, which will in turn affect the stability and robustness of the doubly-fed induction generator (DFIG) wind farm. When integrated with weak grids, the DFIG wind turbine with vector power control often suffers from poor performance and robustness, while the DFIG wind turbine with synchronized control provides better stability. This paper investigates the critical short circuit ratios of DFIG wind turbine with vector power control and synchronized control, to analyze the stability boundary of the DFIG wind turbine. Frequency domain methods based on sensitivity and complementary sensitivity of transfer matrix are used to investigate the stability boundary conditions. The critical capacity of DFIG wind farm with conventional vector power control at a certain point of common coupling (PCC) is obtained and is further increased by employing synchronized control properly. The stability boundary is validated by electromagnetic transient simulation of an offshore wind farm connected to a real regional grid.

Modeling of shallow landslides in an unsaturated soil slope using a coupled model

  • Kim, Yongmin;Jeong, Sangseom
    • Geomechanics and Engineering
    • /
    • v.13 no.2
    • /
    • pp.353-370
    • /
    • 2017
  • This paper presents a case study and numerical investigation to study the hydro-mechanical response of a shallow landslide in unsaturated slopes subjected to rainfall infiltration using a coupled model. The coupled model was interpreted in details by expressing the balance equations for soil mixture and the coupled constitutive equations. The coupled model was verified against experimental data from the shearing-infiltration triaxial tests. A real case of shallow landslide occurred on Mt. Umyeonsan, Seoul, Korea was employed to explore the influence of rainfall infiltration on the slope stability during heavy rainfall. Numerical results showed that the coupled model accurately predicted the poromechanical behavior of a rainfall-induced landslide by simultaneously linking seepage and stress-strain problems. It was also found that the coupled model properly described progress failure of a slope in a highly transient condition. Through the comparisons between the coupled and uncoupled models, the coupled model provided more realistic analysis results under rainfall. Consequently, the coupled model was found to be feasible for the stability and seepage analysis of practical engineering problems.

A Nonlinear Robust Control of Robot Arm with Four Joints Based on Lyapunov Stability Analysis (리아프노프 안정성 해석에 기준한 4축 로봇 아암의 비선형 견실제어)

  • Hyeon, Gi-Kwon;Shim, Hyun-Seok;Yoon, Dae-sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.3
    • /
    • pp.157-166
    • /
    • 2015
  • In this paper, we proposed a new robust control scheme to implement stable control of robot manipulators including nonlinear perameters The proposed robust controller is composed of a nonlinear controller and linear compemsation controller. It shows a good robust performance in reaching mode which does not possess invariance property. Thus, the proposed nonlinear controller showed a good robust performance in the whole region, It was illustrated that the proposed control showed a good transient response and trajectory tracking performance for robot manipulator with four joint by experiments.

The Derivation and Application of Energy Function Reflecting the Governor Cut-off Property (조속기의 CUT-OFF 특성을 반영한 에너지 함수 유도 및 응용)

  • Moon, Young-Hyun;Kim, Hyung-Jun;Ryu, Hun-Su;Cho, Byung-Hoon;Kim, Se-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.84-87
    • /
    • 1996
  • This paper presents a energy function to reflect the control effect of speed governor which has a cut-off property which means position and rate limit The proposed energy function satisfies the semi-negativeness of its time derivative and well reflects the parameters of speed governor to the energy function. The transient stability analysis by the direct method for the single machine infinite bus system has been conducted with the use of the proposed energy function, which shows that the results by the direct method well agree with that by the conventional time simulation method. This thesis shows a possibility of more accurate stability analysis by taking into account the cut-off property of speed governor's output.

  • PDF

Presentation of EMS Real-Time VOLTAGE-VAR-DISPATCH Function & Practical Operating Plan (EMS 실시간 무효전력 최적화 기능 소개 및 활용 방안)

  • Kang, Bu-Il;Cho, Jong-Man;Shin, Yong-Son
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.416-417
    • /
    • 2007
  • With the benifit of telecommunication and IT technologies, Real-time Power system analysis having been gradually progressed. The power system become more complex due to the gradual increment of power demand. We analyze the problems in power system operation, by the use of PSS/E(power flow, fault and transient stability study) and VSAT for voltage stability. The results of establishment of power system operating plan and countermeasure are described.

  • PDF

Safety Evaluation of Agricultural Reservoirs due to Raising Embankment by Field Monitoring and Numerical Analysis (현장계측과 수치해석에 의한 농업용저수지 제체의 안정성 평가)

  • Lee, Kwang Sol;Lee, Dal Won;Lee, Young Hak
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.2
    • /
    • pp.31-44
    • /
    • 2016
  • This study analyzed pore water pressure, earth pressure and settlement through field monitoring on the project site in which raising embankments are being built through backside extension, and compared the behaviors of seepage analysis, slope stability analysis and stress-strain during flood water levels and rapid drawdown under steady state and transient condition. The variation of pore water pressure showed an increase during the later period in both upstream and downstream slope, with downstream slope more largely increased than upstream slope overall. The variation of earth pressure increased according to the increase of embankment heights, while the change largely showed in the upstream slope, it was slowly increased in the downstream slope. The settlements largely increased until 23 m as embankment heights increased, and showed very little settlement overall. Under a steady state and transient conditions, the seepage quantity per day and leakage quantity per 100 m of embankment against total storage were shown to be stable for piping. The hydraulic gradient at the core before and after raising embankments was greater than the limit hydraulic gradient, showing instability for piping. The safety factor of upstream and downstream slopes were shown to be very large at a steady state, while the upstream slopes greatly decreased at a transit conditions, downstream slopes did not show any significant changes. The horizontal settlements, the maximum shear strain and stress are especially distributed at the connecting portion of the existing reservoir and the new extension of backside. Accordingly, the backside extension method should be designed and reinforced differently from the cases of other types reservoirs.

Exact analysis for overload of a charge-pump phase-locked loop (Charge-pump 위상 동기 회로의 과부하에 대한 정확한 해석)

  • 최은창;이범철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3069-3085
    • /
    • 1996
  • This paper shows an accurate charge-pump PLL model which considers the wave-form distortion in high speed operation of charge-pump PLL, the leakage current in loop filter, and a physical limit in charge-pump. With proposed model of charge-pump PLL, overload and stability are derived theoretically and the results are compared to the conventional model. Unlike the ideal charge-pump PLL that simplifies calculations, it is possible to analyze the transient-state and the steady-state at the same time with proposed accurate model. Thus, charge-pump over load, in the transient-state and the stead-state of charge-pump, is accuragely analyzed and the results are confirmed with simulation.

  • PDF

The Development of Graphics Package for Power System Analysis using Object-Oriented Programming (객체지향기법을 이용한 전력계통 해석을 위한 그래픽 소프트웨어 개발)

  • Gim, Jae-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.418-425
    • /
    • 2006
  • This paper describes a simulation package for a power system using objected-oriented programming. The package includes four parts which are a power flow, a short circuit calculation, a transient simulation program, and an economic dispatch. The graphical user interface(GUI) is designed as a common platform which allows the user to create one-line diagrams of systems, specify components of power systems as well as simulation parameters, and view the output produced by the chosen application. The paper presents the data structure of the functional modules such as the draw module, power system data module, the power system simulation module, and the utility module using the object oriented programming. This package may be useful for educational and research purposes.

Modifying the aggregated wind farm model with a controller

  • Badr, Mohammed. A.;Atallah, Ahmed. M.;Bayoumi, Mona A.
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.133-142
    • /
    • 2015
  • A large wind farm can be simplified by the aggregated wind farm models for load flow, steady and transient stability studies. When a fault (such as a short circuit) happens in a large wind farm, some of wind turbines trip while others do not. This paper is to design a controller to modify the aggregated wind farm model in the case of one or more unit removed or added from the complete model. This is without stopping the simulation process during performing the steady state and transient analysis of the whole system. This controller can modulate the status of the wind turbines in the aggregated model in a given farm according to any change in this farm. By this controller, we save effort and time to change the status of wind turbines in the aggregated model. The proposed wind farm is composed of some smaller farms of permanent magnet synchronous generators (PMSGs) and others of squirrel cage induction generators (SCIGs).