• Title/Summary/Keyword: Transient region

Search Result 441, Processing Time 0.023 seconds

Characteristic Features Observed in the East-Asian Cold Anomalies in January 2011 (2011년 1월의 동아시아 한랭 아노말리 특성)

  • Choi, Wookap;Jung, Jiyeon;Jhun, Jong-Ghap
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.401-412
    • /
    • 2013
  • East Asia experienced extremely cold weather in January 2011, while the previous December and the following February had normal winter temperature. In this study National Centers for Environmental Prediction/National Center for Atmospheric Research (NCEP/NCAR) reanalysis data are used to investigate the characteristic features observed in the meteorological fields such as temperature, sea-level pressure, geopotential height, and wind during this winter period. In January the planetary-wave pattern is dominated by stationary-wave form in the mid-to-high latitude region, while transient waves are significant in the previous month. To understand the planetary-wave features quantitatively, harmonic analyses have been done for the 500-hPa geopotential height field. In the climatological-mean geopotential heights the wave numbers 1, 2, and 3 are dominant during the whole winter. In January 2011 the waves of number 1, 2, and 3 are dominant and stationary as in the climatological-mean field. In December 2010 and February 2011, however, the waves of number 4, 5, and 6 play a major role and show a transient pattern. In addition to the distinctive features in each month the planetary-wave patterns dependent on the latitude are also discussed.

Jet Impingement Heat Transfer on a Pedestal Encountered in Chip Cooling (충돌제트를 이용한 pedestal 형상의 칩 냉각연구)

  • Lee, Dae-Hee;Chung, Seung-Hoon;Chung, Young-Suk;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.124-130
    • /
    • 2001
  • The heat transfer and flow measurements were made on a cylindrical pedestal mounted on a flat plate with a turbulent impinging air jet. The heat transfer coefficient distributions on the flat plate were measured using the shroud-transient technique and liquid crystal was used to measure the surface temperature. The jet Reynolds number (Re) is 23,000, the dimensionless nozzle-to-surface distance (L/d) from 2 to 10, the dimensionless pedestal diameter-to-height (H/D) from 0 to 1.5, the dimensionless 2nd pedestal diameter-to-height ($H/D_2$) from 0 to 0.4 and the distance from the stagnation point to 2nd pedestal (p/D). The results show that for H/D = 0.5 to 1.5, the Nusselt number distributions on the plate surface exhibit a maximum between $r/d\;{\cong}\;1.0$ and 1.5. The presence of the pedestal appears to cause the flow separation and reattachment on the plate surface, which results in the maximum heal transfer coefficient. Also, for p/D = 2.5 and $H/D_2$ = 0.3, the local Nusselt number in the region corresponding to $r/d\;{\cong}\;1.1$ was increased up to 50% compared to that for $H/D_2=0$.

  • PDF

Study on Angular Momentum Transfer in Polymer Solutions (폴리머 용액에서의 각운동량 전달에 관한 연구)

  • Kim, Jae-Won;Ahn, Eun-Young;Oh, Jung-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.67-73
    • /
    • 2006
  • This investigation deals with the spin-up flows in a circular container of aspect ratio, 2.0. Shear front is generated in the transient spin-up process and propagating from the side wall to the central axis in a rotating container. Propagation of the shear front to the axis in a rotating container means the region acquires an angular momentum transfer from the solid walls. Propagating speed of the shear front depends on the apparent viscosity of polymer solution. Two kinds of polymer solutions are considered as a working fluid: one is CMC and the other is CTAB solution. CMC solution has larger apparent viscosity than that of water, and CTAB shows varying apparent viscosities depending on the applied shear rates. Transient and spatial variations of the apparent viscosities of the present polymer solutions (CTAB and CMC) cause different speeds of the propagating shear front. In practice, CMC solution that has larger values of apparent viscosity than that of water always shows rapid approach to the steady state in comparison of the behavior of the flows with water. However, for the CTAB solution, the speed of the propagating of the shear front changes with the local magnitude of its apparent viscosity. Consequently, the prediction of Wedemeyer's model quantitatively agrees with the present experimental results.

Surge Phenomena Analytically Predicted in a Multi-stage Axial Flow Compressor System in the Reduced-Speed Zone

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.3
    • /
    • pp.110-124
    • /
    • 2014
  • Surge phenomena in the zone of reduced speeds in a system of a nine-stage axial flow compressor coupled with ducts were studied analytically by use of a surge transient simulation code. Main results are as follows. (1) Expansion of apparently stable, non-surge working area of the pressure vs. flow field beyond the initial stage-stall line was predicted by the code in the lower speed region. The area proved analytically to be caused by significantly mismatched stage-working conditions, particularly with the front stages deep in the rotating stall branch of the characteristics, as was already known in situ and in steady-state calculations also. (2) Surge frequencies were found to increase for decreasing compressor speeds as far as the particular compressor system was concerned. (3) The tendency was found to be explained by a newly introduced volume-modified reduced surge frequency. It suggests that the surge frequency is related intimately with the process of emptying and filling of air into the delivery volume. (4) The upstream range of movement of the fluid mass having once passed through the compressor in surge was found to reduce toward the lower speeds, which could have caused additionally the increase in surge frequency. (5) The concept of the volume-modified reduced surge frequency was able to explain, though qualitatively at present, the behaviors of the area-pressure ratio parameter for the stall stagnation boundary proposed earlier by the author.

Analysis of Fault Diagnosis of Regenerative Braking System for Fuel Cell Vehicle with EMB System (전기기계 브레이크가 적용된 연료전지 자동차의 회생제동 시스템의 고장해석)

  • Song, H.Y.;Choi, J.H.;Hwang, S.H.;Jeon, K.K.;Choi, S.J.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.8-13
    • /
    • 2012
  • Recently, researches about the eco-friendly vehicles such as hybrid electric vehicle, fuel cell vehicle and electric vehicle have been actively carried out. The regenerative braking system is a key technology to improve the vehicle energy utilization efficiency because it transforms the kinetic energy to the electric energy through the electric motor. This new braking system requires cooperative control between electric controlled brake and regenerative brake. Therefore, it is necessary to establish fault-diagnosis and fail-safe evaluation criteria to secure reliability of the regenerative braking system. In this paper, the failure types and causes in regenerative braking system were analyzed. The transient behavior characteristics were examined based on fault-diagnosis and fail-safe upon failure of regenerative braking system.

Measurement of the Local Heat Transfer Coefficient on a Concave Surface with a Turbulent round Impinging Jet (오목표면에 분사되는 난류원형충돌제트에 대한 국소열전달계수 측정에 관한 연구)

  • Lim, K.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.112-119
    • /
    • 1995
  • Measurements of the local heat transfer coeffcients on a spherically concave surface with a round impinging jet are presented. The liquid crystal transient method was used for these measurements. This method, which is a variation on the transient method, suddenly exposes a preheated wall to an impinging jet while video recording the response of liquid crystals for the measurement of the surface temperature. The Reynolds numbers used were 1,000, 23,000 and 50,000 and the nozzle-to-jet distance was L/d=2, 4, 6, 8, 10. Presented results are compared to previous measurements for flat plate. In the experiment, the local heat transfer Nusselt numbers on a concave surface are higher than those on a flat plate. Maximum Nusselt number at all region occured at L/d=6 and second maximum in the Nusselt number occured at R/d=2 for both Re=50,000 and Re=23,000 in case of L/d=2 and for only Re=50,000 in case of L/d=4. All other cases exhibit monotonically decreasing value of the Nusselt number along the curved surface.

  • PDF

Three Dimensional Finite Element Analysis of Free Surface Flow Using Filling Pattern Technique and Adaptive Grid Refinement (형상 충전 및 격자 세분화를 이용한 삼차원 자유 표면 유동의 유한 요소 해석)

  • Kim, Ki-Don;Yang, Dong-Yol;Jeong, Jun-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1348-1358
    • /
    • 2004
  • The filling pattern and an adaptive grid refinement based on the finite element method and Eulerian mesh advancement approach have been developed to analyze incompressible transient viscous flow with free surfaces. The governing equation fur flow analysis is Navier-Stokes equation including inertia and gravity effects. The mixed FE formulation and predictor-corrector method are used effectively for unsteady numerical simulation. The flow front surface and the volume inflow rate are calculated using the filling pattern technique to select an adequate pattern among seven filling patterns at each tetrahedral control volume. By adaptive grid refinement, the new flow field that renders better prediction in flow surface shape is generated and the velocity field at the flow front part is calculated more exactly. In this domain the elements in the surface region are made finer than those in the remaining regions for more efficient computation. The collapse of a water dam and the filling of a fluidity spiral have been analyzed. The numerical results have been in good agreement with the experimental results and the efficiency of the adaptive grid refinement and filling pattern techniques have been verified.

A study on distribution of drop size and injection rate of air-shroud injector sprays under steady and transient injection condition (정상.과도 분사 조건에서의 에어슈라우드 인젝터 분무의 입경.분사량 분포에 관한 연구)

  • Lee, C.H.
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.17-23
    • /
    • 2004
  • Spray characteristics of a twin-hole air shrouded nonle designed for gasoline injectors was investigated by using laser diffraction particle analyzer (LDPA) and tomography reconstruction- A confined spray chamber which is optically accessible through a pair of glass windows was made to simulate the fuel injection condition in intake manifold of gasoline engine. The measurement was applied to the twin hole injector with and without an air shroud. It demonstrates that for the case with an air shroud, fine atomization is achieved and there exists a large number of fine droplets between the region of the main spray streams, which conforms with the spray visualization. The drop size distribution was investigated as a function of elapse time after fuel injection. The distribution was greatly affected by the measurement position from the injector exit. Also, the spatially resolved spray volume fraction and Sauter Mean Diameter (SMD) from line-of-sight data of the LDPA are tomographically reconstructed by Convolution Fourier transformation under the steady injection condition.

  • PDF

LONG-TERM VARIATION STUDY OF CATACLYSMIC VARIABLES WITH PALOMAR TRANSIENT FACTORY

  • YANG, MICHAEL TING-CHANG;CHOU, YI;HU, CHIN-PING;SU, YI-HAO;HSIEH, HUNG-EN;LIN, CHING-PING;CHUANG, PO-SHENG;LIAO, NAI-HUI
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.193-195
    • /
    • 2015
  • The Palomar Transient Factory is a project making use of a Schmidt 48 inch telescope located on the Palomar Mountain, which is surveying the sky with dynamical cadences. It was deployed in 2009 and the observed sky region is over 1200 square degrees. We have studied the long-term periodic variabilities of the known galactic cataclysmic variables (CVs). More than 20 of the sources had been found to have long term periodic signals, ranging from several tens of days to several hundreds of days. Some possible scenarios are proposed to explain the results, such as a magnetic field change of the companion star, precession of the accretion disk, triple systems and superoutburst cycles. Some preliminary discussion will be presented in this article.

The Study on the Efficient HVDC Capacity Considering Extremely Low Probability of 765kV Double Circuit Transmission Lines Trip

  • Moon, Bong-Soo;Ko, Boyung;Choi, Jin-San
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1046-1052
    • /
    • 2017
  • The load on the power grid of South Korea is expected to grow continuously until the late 2020s, and it is necessary to increase the transfer capacity from the Eastern grid to the Seoul-Gyeonggi region by reinforcing the transmission network for the electric power system to remain stable. To this end, the grid reinforcement by two bipole LCC HVDC transmission systems have been considered on account of the public acceptability and high growth of the fault current level, even though an additional 765kV system construction is more economical. Since the probability of the existing 765kV double circuit transmission line trip is extremely low, a dynamic simulation study was carried out to estimate the efficient HVDC capacity able to stabilize the transient stability by utilizing the HVDC overload capability. This paper suggests the application plan to reduce the HVDC construction capacity with ensuring the transient stability during the 765kV line trip.