• Title/Summary/Keyword: Transient phenomenon

Search Result 251, Processing Time 0.026 seconds

Unstable Operation of Francis Pump-Turbine at Runaway: Rigid and Elastic Water Column Oscillation Modes

  • Nicolet, Christophe;Alligne, Sebastien;Kawkabani, Basile;Simond, Jean-Jacques;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.324-333
    • /
    • 2009
  • This paper presents a numerical simulation study of the transient behavior of a $2{\times}340MW$ pump-turbine power plant, where the results show an unstable behavior at runaway. First, the modeling of hydraulic components based on equivalent schemes is presented. Then, the 2 pump-turbine test case is presented. The transient behavior of the power plant is simulated for a case of emergency shutdown with servomotor failure on Unit 1. Unstable operation at runaway with a period of 15 seconds is properly simulated using a 1-dimensional approach. The simulation results points out a switch after 200 seconds of the unstable behavior between a period of oscillations initially of 15 seconds to a period of oscillation of 2.16 seconds corresponding to the hydraulic circuit first natural period. The pressure fluctuations related to both the rigid and elastic water column mode are presented for oscillation mode characterization. This phenomenon is described as a switch between a rigid and an elastic water column oscillation mode. The influence of the rotating inertia on the switch phenomenon is investigated through a parametric study.

A Four-Node Assumed Strain Plate Element for Explicit Dynamic Transient Analysis (명시적인 동적 시간이력해석을 한 사절점 가변형도 평판요소)

  • 이상진
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.3
    • /
    • pp.349-359
    • /
    • 2001
  • An enhanced four-node plate element, which has been developed for explicit dynamic analysis of plate, is described in this paper. Reissner-Mind1in(RM) assumptions are adopted to consider transverse shear deformation effects in the present plate element. RM plate element produces a shear locking phenomena in thin plate so that the substitute natural strains based on assumed strain method are explicitly derived. The present plate element is applied into the explicit transient algorithm and the mass matrix of plate is formulated by using special lumping method proposed by Hinton et al. The performance of the element is verified with numerical examples.

  • PDF

Art Nouveau 1892-1902: Fin de Ciecle or a Transient Phase in Modern Architecture -In Cases of V. Horta, H. Guimard and C.R. Macintosh- (아르누보 건축의 역사적 특성에 관한 연구(1892-1902) -V. 호르타, H. 귀마드, 그리고 C.R. 맥킨토시를 중심으로-)

  • 황보봉;이수진
    • Korean Institute of Interior Design Journal
    • /
    • no.25
    • /
    • pp.198-204
    • /
    • 2000
  • Art Nouveau was a short-lived European phenomenon in art and architecture. Despite the fact that Art Nouveau architecture never fully succeeded as an anti-historical movement, it is important to identify its place in modern architectural historiography. The significance of Art Nouveau-that it incorporated decorative elements into the centre of architectural practice-certainly serves to acknowledge its place within the Modern Movement. Architectural works of Victor Horta, Hector Guimard and Charles Rennie Mackintosh are carefully examined in this paper to find out (1) how they individually emerged and manifested distinctive characteristics and creativity within their own local contexts, and (2) how they can collectively fit into historical discourse of Art Nouveau. Art Nouveau was not a mere fin-de-ci cle phenomenon, but a complicated transient phase at the dawn of European Modernism.

  • PDF

Seepage analysis of agricultural reservoir due to raising embankment (농업용 저수지 둑 높이기에 따른 제체의 침투류 해석)

  • Lee, Dal-Won;Lee, Kwang-Sol;Lee, Young-Hak
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.493-504
    • /
    • 2011
  • This study was carried out to safety evaluation, the practical application and improvement of design method of the agricultural reservoir due to raising embankments. Also, it was to compare and analyze the pore water pressure (PWP), seepage (leakage) quantity and piping phenomenon according to high water table and rapid drawdown. The seepage analysis by finite element analysis was used for steady state and transient condition. The pore water pressure distribution for steady state and transient condition showed positive(+) PWP on the upstream slope, it was gradually changed negative(-) PWP on the downstream slope. The PWP in the core ranged from 100 ~ -33 kPa, the seepage line in the incline-type core suddenly decreased towards the lower levels from the higher levels. The PWP according to rapid drawdown is remained in the vicinity of the upstream slope, therefore, it is investigated to be in an unstable state by the slope stability analysis. The PWP after raising embankments showed smaller than in the before raising embankments. It was likely to be the piping phenomenon because the gradients in the before raising embankments showed largely at downstream slope, and the stability for piping in the after raising embankments increased stable state. The seepage quantity per 1 day and the leakage per 100m for the steady state and transient condition appeared to be safe against the piping. It reduced slightly regardless of the transient condition before the raising embankments and it decreased largely about 2.4 times in the early days after the raising embankments.

The Protection methods of Telecommunication Network from Electrical Transient Phenomena (전기적 과도현상으로부터 통신망의 보호대책)

  • Choi, Man-Ho;Kim, Hyun-Duk;Kim, Byung-Cheul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.693-696
    • /
    • 2005
  • Parallel and cross of the electrical power and telecommunication network is become accelerated, because telecommunication equipments are constructed according to road for efficient maintenance of domestic telecommunication network. The electrical power network can generate an electrostatic induction, and is itself transmission medium from electrical transient phenomenon such as lighting. So, transient phenomenon of lightning surge is induced to telecommunication network, and then it is damaged by connecting between electrical ground of electrical power network and telecommunication network. In this study, we found that cut-off of return path current by separate distance between electrical ground of electrical power network and telecommunication network, and cut-off of electrostatic induction voltage by grounding unused leads of both terminals of the electrical and telecommunication network have good effect as the protection methods of telecommunications network from electrical transient phenomena.

  • PDF

Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator (전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구)

  • Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

Experimental Study on the Flow Hysteresis Phenomenon in a Supersonic Nozzle (초음속 노즐에서 발생하는 유동 이력현상에 대한 실험적 연구)

  • Nam, Jong-Soon;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.206-212
    • /
    • 2011
  • Hysteresis phenomena in fluid flow systems are frequently encountered in many industrial and engineering applications and mainly appear during the transient processes of change of the pressure ratio. Shock-containing flow field in supersonic nozzles is typically subject to such hysteresis phenomena, but associated flow physics is not yet understood well. In the present study, experimental work has been carried out to investigate supersonic nozzle flows during the transient processes of change in the nozzle pressure ratio. Time-dependent surface wall pressures were measured by a multiple of pressure transducers and the flow field was visualized using a nano-spark Schlieren optical method. The results obtained show that the hysteresis phenomenon is strongly dependent on the nozzle geometry as well as the time scale of the change of pressure ratio.

  • PDF

Digital Time-Domain Simulation of Ferroresonance of Potential Transformer in the 154 kV GAS Insulated Substation

  • Shim, Eung-Bo;Woo, Jung-Wook;Han, Sang-Ok
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.9-14
    • /
    • 2001
  • This paper reports a set of digital time-domain simulation studies conducted on 154 kV wound Potential Transformer(PT) int he 154 kV Gas Insulated Substation(GIS). The Electro-Magnetic Transient Program(EMTP) is used to develop the PT model and conduct the transient studies. The accuracy of the PT model is verified through comparison of the EMTP simulation results with those obtained from the field test results. The investigations shows that the developed model can accurately predict PT transient resonance, especially, the phenomenon of ferroresonance. The model is developed not only to determine impact of transients on PT response but also to design ferroresonance suppressor devices of PT. And it can also be used to predict PT transient response on power system monitoring and protection scheme.

  • PDF