• Title/Summary/Keyword: Transient period

Search Result 439, Processing Time 0.029 seconds

Utilizing chromosome segment substitution lines (CSSLs) to evaluate developmental plasticity of root systems in hardpan penetration and deep rooting triggered by soil moisture fluctuations in rice

  • Nguyen, Thi Ngoc Dinh;Suralta, Roel R.;Mana, Kano-Nakata;Mitsuya, Shiro;Stella, Owusu Nketia;Kabuki, Takuya;Yamauchi, Akira
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.321-321
    • /
    • 2017
  • Water availability in rainfed lowlands (RFL) is strongly affected by climate change. In RFL, rice plants are exposed to soil moisture fluctuations (SMF) but rarely to simple progressive drought as widely believed. Typical RFL field is characterized by a about 5-cm thick high bulk density hardpan layer underneath the cultivated layer at about 20 cm depth that impedes deep root development. Root system has the ability to develop in response to changes in SMF, known as phenotypic plasticity. We hypothesized that genotypes that can adapt to RFL have root plasticity. The roots can sharply respond to re-wetting after drought period and thus penetrate the hardpan layer when the hardpan is wet and so becomes relatively soft, and thus access water under the hardpan. This study aimed to identify CSSLs derived from a cross between Sasanishiki and Habataki which adapted to such RFL conditions. We used 39 CSSLs together with the parent Sasanishiki, which were grown in hydroponics and pot under transient soil moisture stresses (drought and then rewatering), and compared with continuously well-watered (WW) (control) up to 14 days after sowing (DAS), and 20 DAS, respectively. Based on the results of hydroponics and pot experiments, we selected a few lines, which were grown in the soil-filled rootbox with artificial hardpan layer and without artificial hardpan. For the rootbox without artificial hardpan, plants were grown under WW and transient soil moisture stresses for 49 DAS. While the rootbox with artificial hardpan, the plants were grown under WW (control) and SMF (WW up to 21 DAS, 1st drought (22-36 DAS), rewatering (37-44 DAS), and followed by 2nd drought (45-58 DAS)). Among the 39 CSSLs, only CSSL439 (SL39) consistently showed significantly higher shoot dry weight (SDW) than Sasanishiki under transient soil moisture stress conditions as well as SMF conditions in all the experiments. Furthermore, under WW, SL39 consistently showed no significant differences from Sasanishiki in shoot and root growth in most of traits examined. SL39 showed significantly greater total root length (TRL) than Sasanishiki under transient soil moisture stress, which is considered as phenotypic plasticity in response to rewatering after drought period. Such plastic root development was the key trait that effectively contributed to root elongation and branching during the rewatering period and consequently enhanced the root to penetrate hardpan layer when the soil penetration resistance at hardpan layer reduced. In addition, using the rootbox with artificial hardpan layer ($1.7g\;cm^{-3}$, heavily compacted), SL39 showed greater root system development than Sasanishiki under SMF, which was expressed in its significantly higher TRL, total nodal RL, and total lateral RL at hardpan layer as well as at below the hardpan layer. These results prove that SL39 has plasticity that enables its root systems to penetrate hardpan layer in response to rewatering. Under SMF, such root plasticity contributed to its higher gs and Pn.

  • PDF

Evaluation Method for the Water Transport Properties of Sweat Absorbent Fabrics - Water Vapour Transport in the of Human-Clothing-Environment System - (첨단 흡수속건소재의 수분전달 특성 평가방법에 관한 연구 - 인체-의복-환경 System에서의 투습성 평가 -)

  • Kim, Eun Ae;Barker, Roger L.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.2
    • /
    • pp.329-338
    • /
    • 1993
  • The purpose of this study was to design an instrument to simulate the Human-Clothing-Environment system and evaluate the water vapour transport properties of sweat absorbent PET fabrics. The instrument was composed of sweat generating part, clothing part which can simulate clothing layers, and enviromental part. As specimens, sweat absorbent PET, regular PET, cotton, nylon and acrylics fabrics were included. For the water vapour transport(WVT), relative humidities and temperatures were measured by film type humidity sensors and thermocouples, respectively. Water vapour pressures were calculated with measured RH's and temperatures. For the liquid water transport, wickability and demand wettability were measured. Results showed that there was a difference in terms of water vapour transport mechanism depending on the fiber type ; sweat absorbent PET showed higher WVT at the transient period then equilibrated, whereas other fabrics showed lower WVT at the transient period then increased continuously. These differences are expected to affect to the difference in the comfort properties of clothings. Sweat absorbent PET showed higher demand wettability and wickability than other fabrics. Wide application of the instrument was also suggested.

  • PDF

Operational Method of Superconducting Fault Current Limiter with Reduction Function of Asymmetric Fault Current (비대칭 고장전류 저감 기능을 갖는 초전도 한류기 동작 방안)

  • Kim, Chang-Hwan;Seo, Hun-Chul;Kim, Kyu-Ho;Kim, Chul-Hwan;Rhee, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.56-62
    • /
    • 2014
  • When fault currents contain decaying DC offset, the peak value of the fault current in the first cycle of the fault period is higher than the fault current during the steady-state period. To reduce the asymmetric fault current, this paper proposes an operation scheme using the series connection of two hybrid type Superconducting Fault Current Limiters (SFCLs) : an auxiliary SFCL and a main SFCL. The proposed method calculates the fault angle by comparing the zero-crossing time with fault detection time. According to the fault angle calculated, an auxiliary SFCL operates to reduce an asymmetric fault current during half a cycle after fault occurrence. After this process, the fault current is limited by a main SFCL. To confirm the usefulness of the proposed method, case studies using Electro-Magnetic Transients Program (EMTP)/Alternative Transient Program (ATP) Draw are perfomed.

CHANGE OF CATALYST TEMPERATURE WITH UEGI TECHNOLOGY DURING COLD START

  • CHO Y.-S.;KIM D.-S.
    • International Journal of Automotive Technology
    • /
    • v.6 no.5
    • /
    • pp.445-451
    • /
    • 2005
  • Most of the pollutants from passenger cars are emitted during the cold-transient phase of the FTP-75 test. In order to reduce the exhaust emissions during the cold-transient period, it is essential to warm up the catalyst as fast as possible after the engine starts, and the Unburned Exhaust Gas Ignition (UEGI) technology was developed through our previous studies to help close-coupled catalytic converters (CCC) reach the light-off temperature within a few seconds after cold-start. The UEGI system operates by igniting the unburned exhaust mixture by glow plugs installed upstream of the catalyst. The flame generates a high amount of heat, and if the heat is concentrated on a specific area of monolith surface, then thermal crack or failure of the monolith could occur. Therefore, it is very important to monitor the temperature distribution in the CCC during the UEGI operation, so the local temperatures in the monolith were measured using thermocouples. Experimental results showed that the temperature of CCC rises faster with the UEGI technology, and the CCC reaches the light-off temperature earlier than the baseline case. Under the conditions tested, the light-off time of the baseline case was 62 seconds, compared with 33 seconds for the UEGI case. The peak temperature is well under the thermal melting condition, and temperature distribution is not so severe as to consider thermal stress. It is noted that the UEGI technology is an effective method to warm up the catalyst with a small amount of thermal stress during the cold start period.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Transient Adverse Neurologic Effects of Spinal Pain Blocks

  • Lee, Han-Il;Park, Yong-Sook;Cho, Tack-Geun;Park, Seung-Won;Kwon, Jeong-Taik;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.228-233
    • /
    • 2012
  • Objective : Chronic neck or back pain can be managed with various procedures. Although these procedures are usually well-tolerated, a variety of side effects have been reported. In this study we reviewed cases of unexpected temporary adverse events after blocks and suggest possible causes. Methods : We reviewed the records of patients treated with spinal pain blocks between December 2009 and January 2011. The types of blocks performed were medial branch blocks, interlaminar epidural blocks and transforaminal epidural blocks. During the first eight months of the study period (Group A), 2% mepivacaine HCL and triamcinolone was used, and during the last six months of the study period (Group B), mepivacaine was diluted to 1% with normal saline. Results : There were 704 procedures in 613 patients. Ten patients had 12 transient neurologic events. Nine patients were in Group A and one was in Group B. Transient complications occurred in four patients after cervical block and in eight patients after lumbar block. Side effects of lumbar spine blocks were associated with the concentration of mepivacaine (p<0.05). The likely causes were a high concentration of mepivacaine in five patients, inadvertent vascular injection in three patients, intrathecal leak of local anesthetics in one, and underlying conversion disorder in one. Conclusion : Spinal pain blocks are a good option for relieving pain, but clinicians should always keep in mind the potential for development of inevitable complications. Careful history-taking, appropriate selection of the anesthetics, and using real-time fluoroscopy could help reduce the occurrence of adverse events.

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF THERMAL STRATIFICATION IN THE UPPER PLENUM OF THE MONJU FAST BREEDER REACTOR (몬주 고속증식로 상부플레넘에서의 열성층에 관한 전산유체역학 해석)

  • Choi, S.K.;Lee, T.H.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.41-48
    • /
    • 2012
  • A numerical analysis of thermal stratification in the upper plenum of the MONJU fast breeder reactor was performed. Calculations were performed for a 1/6 simplified model of the MONJU reactor using the commercial code, CFX-13. To better resolve the geometrically complex upper core structure of the MONJU reactor, the porous media approach was adopted for the simulation. First, a steady state solution was obtained and the transient solutions were then obtained for the turbine trip test conducted in December 1995. The time dependent inlet conditions for the mass flow rate and temperature were provided by JAEA. Good agreement with the experimental data was observed for steady state solution. The numerical solution of the transient analysis shows the formation of thermal stratification within the upper plenum of the reactor vessel during the turbine trip test. The temporal variations of temperature were predicted accurately by the present method in the initial rapid coastdown period (~300 seconds). However, transient numerical solutions show a faster thermal mixing than that observed in the experiment after the initial coastdown period. A nearly homogenization of the temperature field in the upper plenum is predicted after about 900 seconds, which is a much shorter-term thermal stratification than the experimental data indicates. This discrepancy is due to the shortcoming of the turbulence models available in the CFX-13 code for a natural convection flow with thermal stratification.

A Performance Improvement of Exciter Control System of Synchronous Generator using Transient Response Compensator (과도 응답 보상기를 가지는 동기발전기의 고성능 여자 제어시스템)

  • Lee, Dong-Hee;Wang, Huijun;Kim, Tae-Hyoung;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.82-89
    • /
    • 2007
  • AVR(Automatic Voltage Regulator) of exciter control system in AC generator controls voltage and current according to load and terminal voltage variations in order to remain at the bus voltage. The output characteristics of main generator is dependent on the control performance of AVR. This paper presents the PWM type exciter system with transient response compensator for robust control of load variations. Additional transient response compensator generates compensation signal for load variation. So the proposed excitation control system has fast dynamic response in transient period and can control terminal voltage constantly. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

A Numerical Study on Transient Performance Behavior of a Turbofan Engine with Variable Inlet Guide Vane and Bleed Air Schedules (가변 입구 안내익과 블리드 공기 스케줄에 따른 터보팬 엔진에서의 천이 성능특성에 관한 수치연구)

  • Kim, Sangjo;Son, Changmin;Kim, Kuisoon;Kim, Myungho;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.5
    • /
    • pp.52-61
    • /
    • 2015
  • This paper performed a numerical study to analyse the transient performance behavior of a turbofan engine with variable inlet guide vane (IGV) and bleed air schedules. The low bypass ratio mixed flow turbofan engine was considered in this study. For modeling the compressor performance with IGV, the performance maps were generated by using a one-dimensional meanline analysis and feed to the engine simulation program. The IGV and bleed air according to the rotating speed were scheduled to satisfy 10% of surge margin at steady-state condition. The transient engine performance analysis was conducted with the schedules. The engine with IGV schedule showed a higher surge margin and lower turbine inlet temperature than the engine with bleed air schedule during the transient period.

Three-Phase Bone Scintigraphic Diagnosis of Acute Transient Synovitis (3상 골신티그램을 이용한 급성 일과성 활막염의 진단)

  • Chung, Soo-Kyo;Lee, Myung-Hee;Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.1
    • /
    • pp.73-75
    • /
    • 1985
  • Acute transient synovitis of the hip presents clinically pain and limping. But in the majority of the cases, definite positive findings are not manifest in roentgenogram in its early phase. However radionuclide bone imaging combines with the assessment of vascularization and bone tracer uptake is of great value in solving this diagnostic problem. The materials for this study consisted of 29 children with acute transient synovitis of the hip, characterized by symptoms and physical signs of an arthritis, negative X-ray findings and disappearance of all symptoms and signs within a short period of time. They were twenty males and 9 females and age ranged from 1 to 12 years. We took pelvic reontgenogram in AP and frog-leg views. After intravenous bolus injection of 10 to 15 mCi of $^{99m}Tc-methylene$ diphosphonate, 24 sequential image of the pelvis was taken at 2-second interval for blood flow study. The scintigrams were made using a gamma camera with high resolution parallel hole collimator. Blood pool imaging was obtained at 2 minutes after tracer administration. After 3 hours, static images were taken and then closeup image of the hip using pin-hole collimator was followed. The results were as follows: 1) Bone scintigram was much more sensitive than conventional roentgenogram in diagnosis of acute transient synovitis of the hip. 2) Three-phase imagings showed increased vascular activities in blood pool scintigrams in 96%. 3) Pin-hole imaging showed increased tracer uptake in the regional bones of the hip, par ticularly in the medial aspect of femoral head and acetabulum. 4) We confirmed that three-phase imaging reinforced with pin-hole technique were very useful in diagnose of acute transient synovitis of the hip.

  • PDF