• 제목/요약/키워드: Transient flow analysis

검색결과 534건 처리시간 0.031초

Decentralized Neural Network-based Excitation Control of Large-scale Power Systems

  • Liu, Wenxin;Sarangapani, Jagannathan;Venayagamoorthy, Ganesh K.;Liu, Li;Wunsch II, Donald C.;Crow, Mariesa L.;Cartes, David A.
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권5호
    • /
    • pp.526-538
    • /
    • 2007
  • This paper presents a neural network based decentralized excitation controller design for large-scale power systems. The proposed controller design considers not only the dynamics of generators but also the algebraic constraints of the power flow equations. The control signals are calculated using only local signals. The transient stability and the coordination of the subsystem control activities are guaranteed through rigorous stability analysis. Neural networks in the controller design are used to approximate the unknown/imprecise dynamics of the local power system and the interconnections. All signals in the closed loop system are guaranteed to be uniformly ultimately bounded. To evaluate its performance, the proposed controller design is compared with conventional controllers optimized using particle swarm optimization. Simulations with a three-machine power system under different disturbances demonstrate the effectiveness of the proposed controller design.

폐기물 소각로 베드에서의 연소현상 관찰을 위한 실험적 연구 (An Experimental Study on the Bed Combustion Phenomena in MSW(Municipal Solid Waste) Incinerator)

  • 민지현;신동훈;최상민
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.159-165
    • /
    • 1999
  • Experimental studies have been performed to observe the basic phenomena of waste bed combustion in MSW incinerator. A reduced scale apparatus was utilized to simulate the combustion behavior in real plant with 1-dimensional transient behavior at the experimental setup, which uses wet cubic wood with ash content as simulated waste. LHV (lower heating value) of solid fuel, fuel particle size and flow rate of combustion air were taken as important parameters of the bed combustion. For the quantitative analysis, FPR (flame propagation rate), TBT (total burn-out time) and PBT (particle burn-out time) was defined. LHV represent the capability of heat release of the fuel, so that a higher LHV results in faster reaction rate of the fuel bed, which is shown by higher FPR. Fuel particle size is related with surface area per unit mass as well as heat and mass transfer coefficient. As the particle size increases the FPR decreases owing to decreasing specific surface area. Air injection supplies oxygen to the reaction zone. However oversupply of combustion air increases convection cooling of the bed and possibly extinguishes the flame.

단기간 기관지 삽관후의 음성의 변화 (Effect of Short-Term Endotracheal Intubation on Vocal Function)

  • 장혁기;강무완;최정환;유영삼;우훈영;윤자복
    • 대한후두음성언어의학회지
    • /
    • 제11권1호
    • /
    • pp.64-68
    • /
    • 2000
  • Background and Objectives : To assess the role of altered vocal function in transient voice change after short-term endotracheal intubation, we evaluated acoustic parameters, aerodynamic parameters, and laryngoscopic characteristics preoperatively and postoperatively. Materials and Methods : Vocal function of 10 patients undergoing tympanoplasty and mastoidectomy using general anesthesia and endotracheal intubation were studied preoperatively, at 1day and 7 days after extubation. Acoustic analysis, aerodynamic study, and telescopic examination were used to assess vocal function. Results : In acoustic parameters, there was no significant difference between preoperative and postoperative measures. However, in subglottic pressure, ere was a significant decrease at 1 day after extubation and this change was return to preoperative value at 7 days after extubation. MPT(Maximal Phonation Time), MER(Mean flow Ratio), and VC(Vital Capacity) were decreased 1 day after extubation but did not show statistically significant change. Three of 10 patients manifested a vocal fold edema and injection 1 day after extubation. Conclusions : Subglottic pressure revealed a significant decrease at 1 day after extubation. And this change was correlated with laryngeal morphologic change and decrement in pulmonary function.

  • PDF

ANALYSIS OF THE ISP-50 DIRECT VESSEL INJECTION SBLOCA IN THE ATLAS FACILITY WITH THE RELAP5/MOD3.3 CODE

  • Sharabi, Medhat;Freixa, Jordi
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.709-718
    • /
    • 2012
  • The pressurized water reactor APR1400 adopts DVI (Direct Vessel Injection) for the emergency cooling water in the upper downcomer annulus. The International Standard Problem number 50 (ISP-50) was launched with the aim to investigate thermal hydraulic phenomena during a 50% DVI line break scenario with best estimate codes making use of the experimental data available from the ATLAS facility located at KAERI. The present work describes the calculation results obtained for the ISP-50 using the RELAP5/MOD3.3 system code. The work aims at validation and assessment of the code to reproduce the observed phenomena and investigate about its limitations to predict complicated mixing phenomena between the subcooled emergency cooling water and the two-phase flow in the downcomer. The obtained results show that the overall trends of the main test variables are well reproduced by the calculations. In particular, the pressure in the primary system show excellent agreement with the experiment. The loop seal clearance phenomenon was observed in the calculation and it was found to have an important influence on the transient progression. Moreover, the collapsed water levels in the core are accurately reproduced in the simulations. However, the drop in the downcomer level before the activation of the DVI from safety injection tanks was underestimated due to multi-dimensional phenomena in the downcomer that are not properly captured by one-dimensional simulations.

ER 유체를 이용한 반능동 완충장치의 동적 특성 (Dynamic Characteristics of Semi-Active Shock Absorber Using Electrorheological Fluid)

  • 김도형;조기대;정용현;이인
    • 한국소음진동공학회논문집
    • /
    • 제11권4호
    • /
    • pp.13-21
    • /
    • 2001
  • Electrorheological(ER) fluid is a kind of smart material with variable shear stress and dynamic viscosity under various electric field intensity. Electric field can control the damping characteristics of ER damper. The objective of this study is the analysis of the performance of ER damper and its application to shock absorber. Idealized nonlinear Bingham plastic shear flow model is used to predict the velocity profile between electrodes. Cylindrical dashpot ER damper with moving electrode is constructed and tested under various electric fields. The analytic and experimental results for damping force are compared and discussed. Drop test system using ER damper is prepared to identify transient vibration characteristics. The rebound is eased as the applied electric field increases. When semi-active control algorithm is applied, rebound phenomenon disappears and vibration energy level decays faster than the case of zero electric field.

  • PDF

CFD에 의한 Axial Reactor Type 자외선 유수살균장치의 출구 위치에 따른 UV Dose 예측 (UV Dose Predictions for Ultra Violet Flowing Water Purification of Axial Reactor Type based on the location of the exit by CFD)

  • 최종웅;김성수;박노석;이영주;채선하
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.521-533
    • /
    • 2012
  • Interest in application of ultraviolet light technology for primary disinfection that used for the treatment of water for consumption and wastewater has increased significantly in recent years. Analysis of these systems has been carried out using Computational Fluid Dynamics (CFD) procedure. It offers advantages over other techniques in specific circumstances. CFD has emerged as a powerful tool to aid design of a UV reactor by providing the UV dose delivered by the proposed reactor design and allowing engineers to evaluate alternative designs in much less time and at a reasonable cost. In this study, five different configurations of the apparatus depending on the location of the exit are evaluated in terms of maximum dose, minimum dose, flow patterns, particle tracks and transient dose. The configuration 3 results have higher minimum UV dose value and uniform particle distribution of the UV dose on the outlet than other's.

상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석 (WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STAT10N CAUSED BY PASSING TRAINS)

  • 이명성;이상혁;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 춘계 학술대회논문집
    • /
    • pp.64-67
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is obtained with actual operational condition of subway train and the moving mesh technique is adopted considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel of platform are included in a computational domain and detailed shape of train is also modeled Numerical analyses were conducted on five operational condition which are different velocity variation of subway train, existence of stationary train and passing each other trains. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation was found to be satisfactory to various foreign standards.

  • PDF

화재가열을 받은 고강도 콘크리트를 충전한 CFT 기둥의 내화성능 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Fire-Resist Performance of High-Strength Concrete Filled steel Tube Column at Fire)

  • 이형준;이태규;김영선;한희철;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.193-197
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) that is an excellent internal force and deformation capacity because material and method are required to be diversification and High-Performance according to increase the super-high structure. And it is proposed to use high-strength Concrete Filled steel Tube Column. But it is difficult quantitative evaluation about fire-resist performance of CFT because steel tube bind concrete. Also, the case of high strength CFT is feared that spalling occur inside. Therefore, this study made CFT specimen that determine the factor(which is strength of concrete) and then CFT column was exposed to heating controlled as closely as possible the ISO-834 standard fire curve. Also, it tried to analyze internal temperature through nonlinear transient heat flow analysis.

  • PDF

두개의 열원이 부착된 히트파이프의 동작 특성 (Operating characteristics of a heat pipe with two heat sources)

  • 박종흥;노홍구;이재헌
    • 대한기계학회논문집B
    • /
    • 제22권3호
    • /
    • pp.303-315
    • /
    • 1998
  • Numerical and experimental studies on a heat pipe with two heat sources have been performed to investigate the operating characteristics. Numerical analysis was performed based on the cylindrical two-dimensional incompressible laminar flow for the vapor space and the conjugate heat transfer for the entire heat pipe. Experimental study with a 0.45 m length copper-water heat pipe was also performed to validate the numerical modeling for the heat input range from 29 W to 47 W on each heater. As results, the temperature profiles at the outer wall for the single active heat source as well as the temperature profiles for the switching operation between two heat sources are suggested. Due to the axial conduction, it is found that the temperature drop between the evaporator and the condenser appears small when the heat source closer to the condenser is turned on. For the switching operation in the present study, the transient time is about 700s and the temperatures at the locations of both heat source are same in 130s after switching.

상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석 (WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STATION CAUSED BY PASSING TRAINS)

  • 이명성;이상혁;허남건
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.1-6
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is used with actual operational condition of subway train by adopting the moving mesh technique considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel connecting the stations are included in a computational domain with modeling the detailed shape of the train. Numerical analyses are conducted on five operational conditions which include the variation of the train speed, case with or without the train stopped in the other track, and case for two trains passing each other inside the station. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation for the cases considered in the present study is found to be satisfactory to various foreign standards.