• Title/Summary/Keyword: Transient System Simulation 프로그램

Search Result 36, Processing Time 0.019 seconds

Analysis on transient stability for drilling rigs power system (석유 시추선 전력 계통의 과도 안정도 해석)

  • Kim, Yoon-Sik;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1119-1124
    • /
    • 2014
  • This paper describes the emergency situation which occurs in Drilling Rig power system. Especially, we focused on power system transient characteristics on propulsion motor load and generator elimination situation in Drilling Rig operation. We performed numerical simulation and analyzed the result for power system transient stability characteristics on each condition for excitation system and governor control system using ETAP (Electrical Transient Analysis Program).

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facilities (향온시설물에 대한 현열 및 잠열 에너지 회수시스템의 성능해석)

  • 박병규;김무근;김근오
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1057-1065
    • /
    • 2000
  • A sizing of sensible and latent energy recovery system with condensing heat exchanger is important to the design of a thermally controlled facilities. The transient system simulation program TRNSYS 14.2/IISiBat has been used to evaluate the energy consumptions of a thermally controlled facilities which consist of boiler, chiller and condensing heat exchanger, The boiler and chiller are selected based on the annual peak loads and controlled to maintain the setting temperature of $14~17^{\circ}C$. Simulation shows that the amount of sensible and latent energy recovered by heat exchanger is almost 20% of total heating load.

  • PDF

Development of Transient Simulation Program for Smart UAV Propulsion System (스마트 무인기 추진기관의 천이 모사 프로그램 개발)

  • Lee, Chang-Ho;Ki, Ja-Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.6
    • /
    • pp.63-69
    • /
    • 2011
  • The Smart UAV must have the control characteristics of propulsion system necessary for both rotary aircraft and fixed wing aircraft though it equips turbo-shaft engine. To develop an electronic engine controller in the future, it is necessary to accumulate the experience of engine operation and data of tilt rotor aircraft. For this purpose, the computer programs which predict engine performance in the steady state and transient state can be utilized for the supplementation of flight test data. In this work, we developed a dynamic analysis program using engine performance data gathered during the flight tests. In addition the accuracy of the program was verified through comparison with flight test data and the results of steady-state performance analysis program.

Development of the Dynamic Simulation Program for the Multi-Inverter Heat Pump Air-Conditioner (멀티 인버터 히트펌프의 동특성 해석 프로그램의 개발)

  • ;;小山繁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1079-1088
    • /
    • 2001
  • A dynamic simulation model was developed to analyse the transient characteristics of a multi-inverter heat pump. The programs included a basic air conditioning system such as a evaporator, condenser, compressor, linear electronic expansion valve (LEV) and by-pass circuit. The theoretical model was derived from mass conservation and energy conservation equations to predict the performance of the multi-inverter heat pump at various operating conditions. Calculated results were compared with the values obtained from the experiments at different operation frequencies of compressor, area of the LEV and configuration of indoor units operation. The results of the simulation model showed a good agreement with the experimental ones, so that the model could be used as an efficient tool for thermodynamic design and control factor design of air-conditioners.

  • PDF

A Study on the Electromagnetic Transients at Switching Capacitor Banks in a Electric Distribution Electric Power Distribution Substation (배전변전소에서 캐패시터 뱅크 투입시 일어나는 전자과도 현상에 관한 연구)

  • 김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.92-99
    • /
    • 2002
  • Transient in an electric distribution system are mainly generated by switching. This paper presents analysis of switching surge and means of limiting the voltage magnification transient for high voltage power systems by using the EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor contraction capacitor banks to harmonics filters. An inductance in series with the capacitor bank was used to decrease the transient voltage at the customer bus to acceptable levels. And also simulation results used the EDSA harmonics analysis program show the effect of harmonics reduction.

Calculation Method of Transient Potential Rises of Horizontal Ground Electrodes Depending on Injection Point of the Ground Current (접지전류의 입사점에 따른 정보통신설비용 수평접지전극의 과도전위상승 계산 방법)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.197-203
    • /
    • 2014
  • When the lightning current is injected to the ground system of information and communication facilities, analysis of the transient potential rise in the ground system is one of main factors to effectively design the ground system. The performance of grounding systems is normally estimated with the grounding impedance and the transient potential rise which represents the electrical characteristics of the grounding system. The method for calculating the grounding impedance depending on the injection point of the lightning current was proposed. The delta-gap source model was proposed to calculate the grounding impedance in the case that the lightning current is injected to the center of the horizontal ground electrode. A new program which is possible to apply the frequency-dependent soil parameters using the Debye model was developed, because a commercial program for analyzing the performance of the grounding system can not apply to the frequency-dependent soil parameters. The experiment was carried out to confirm the availability of the simulation results with the same condition. Finally, the transient potential rises of a horizontal ground electrode depending on the lightning current waveforms were analyzed by using the results of the grounding impedance which is associated with the frequency-dependent soil parameters.

Development of Contingency Screening Module for Transient Stability Analysis Program (과도 안정도 해석 프로그램을 위한 상정사고 스크리닝 모듈 개발)

  • Hwang, Jung-Hee;Kim, Chon-Hoe;Jang, Gil-Soo;Lee, Byung-Jun;Kwon, Sae-Hyuk;Cho, Yoon-Sung;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.335-337
    • /
    • 2005
  • The purpose of this work is to explain techniques achieved while developing a transient stability program which is suitable to Korean power system, and to add a module for contingency screening. It concentrates on the development of Contingency Screening Module. In this thesis, a fast contingency screening algorithm SIME(Single Machin Equivalent), which is one of the Hybrid methods for the transient stability assessment is used to develop the contingency screening module. The proposed module is applied to a KEPCO system, and simulation results obtained from the program are compared to those of commercial programs.

  • PDF

The Merger of Transient Stability Analysis Program for dynamic models (다이나믹 모델의 과도 안정도 해석 프로그램 통합)

  • Sim Gyu Sang;Cho Yoon Sung;Jang Gil Soo;Lee Byong Jun;Kwon Sae Hyuk
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.239-241
    • /
    • 2004
  • The purpose of this paper is to explain techniques achieved while developing a transient stability program which is suitable to Korean power system. It concentrates on the development of a synchronous machine model, exciter models and turbine-governor models used in large-scale power system stability analysis. These proposed models enhance the performance of the developing program. This developing program has been tested with the KEPCO system, and the simulation results obtained from the program are compared to those of commercial programs.

  • PDF

Development and Application of Power System Stability Analysis Program Using OOP (개체지향기반 안정도 해석 프로그램 개발 및 적용)

  • 박지호
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.194-202
    • /
    • 2002
  • In this paper, we simulate the power system transient stability of Kwang Yang steel works using object-oriented programming (OOP). OOP is a more flexible method than procedural programming. There are several advantages in dynamic system simulation using OOP, The maintenance and repair of program are easy because it is sufficient to modify necessary parts which correspond to the change of system without overall change of program. We have implemented a graphical man-machine interface (MMI) that can be used draw one-line system diagram and analyze power flow and dynamic stability. The implemented MMI also provide a graphical viewer that display dynamic stability analysis results by mouse event handling. The proposed method have been applied to Kwang Yang steel works network for on-line dynamic stability analysis. The dynamic behaviour of 17 synchronous generators and 25 synchronous motors has been studied in the Kwang Yang network.

Selection of the time Integration algorithm for transient stability analysis program (과도 안정도 해석 프로그램을 위한 최적 시 적분 알고리즘 선정방안)

  • Kim, D.J.;Cho, Y.S.;Jang, G.;Lee, B.;Kwon, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.122-124
    • /
    • 2003
  • Power system analysis is generally based on computer simulation and time-domain simulation is used to assess it's dynamic performance. This paper deals with the selection of proper integration engine for large-scale power system dynamic simulation. Simulation results obtained from the selected algorithm are compared to those of commercial program.

  • PDF