• 제목/요약/키워드: Transient Probe method

검색결과 22건 처리시간 0.024초

과도탐침법에 의한 열전도계수 측정장치 개발 (Development of Experimental Apparatus For Measuring Thermal Conductivity by Transient Probe Method)

  • 배신철;김명윤
    • Journal of Biosystems Engineering
    • /
    • 제22권1호
    • /
    • pp.59-67
    • /
    • 1997
  • An experimental apparatus was developed for the rapid determination of thermal conductivity by transient probe method. The theoretical basis for transient probe method has been investigated. The mathematical model for this method is the Carslaw and Jaeger model which is used perfect line source theory. The small needle probe which is equipped with thermocouple and heating element is constructed. A software that performs data analysis and acquisition is programmed. The influence of the power dissipated per unit length of the probe has been assessed for glycerin. The result showed no significant correlation between thermal conductivity and power input. Determination made with this experimental apparatus were found to agree well with the recommended thermal conductivity data.

  • PDF

과도탐침법을 이용한 액체의 열물성 동시측정 (The simultaneous measurement for thermal properties of liquids using transient probe method)

  • 배신철;김명윤
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.303-315
    • /
    • 1997
  • The theoretical model for the transient probe method is the modified Jaeger model which is used perfect line source theory. The transient probe technique has been developed for the simultaneous determination of thermal conductivity, diffusivity and volumetric heat capacity of liquids. The Levenberg-Marquardt iteration method is adapted to obtain thermal property within nonlinear range. Experimental results of liquids were found to agree well with recommended thermal property data.

순간흡수 분광학 측정장치 구성 및 DDI의 순간흡수율 변화 측정 (Fabrication of Transient Absorption Spectroscopic System and Measurement of Transient Absorption Changes of DDI)

  • 서정철;이민영;김동호;정홍식;박승한;김웅
    • 한국광학회지
    • /
    • 제2권4호
    • /
    • pp.209-213
    • /
    • 1991
  • 최근들어 극초단 광학펄스를 생성하고 증폭하는 기술의 발달로 인하여 시분해 레이저 분광학에 많은 영향을 끼치게 되었다. 그 중에서도 응용성이 넓은 순간흡수분광학장치를 본 연구실에서 개발하였다. 이 기술은 고출력 레이저 펄스를 이용하여 white light continuum pulse를 생성시켜 이를 조사빔으로 이용하고, pump pulse는 원래 상태의 레이저를 이용하는 것이다. 순간흡수율 변화를 여러 파장에서 측정가능하도록 photodiode array를 이용하였으며, pump와 probe pulse의 시간차이에 의한 순간흡수율 변화를 색소의 일종인 DDI를 이용하여 측정하였다.

  • PDF

펌프-촉침 방법을 이용한 피코초 순간 흡광 속도분광기 제작

  • 장두전
    • 한국광학회지
    • /
    • 제4권3호
    • /
    • pp.347-353
    • /
    • 1993
  • 펌프-촉침 방법을 이용한 피코초 순간 흡광 속도분광기를 제작하고 피코초 순간 흡광 분광을 측정하는 다른 방법들과 비교하였다. 제작된 피코초 순간 흡광 속도분광기는 모드 록킹된 cw 색소 레이저에서 발생된 펌프 펄스와 촉침 펄스 사이의 지연시간 변화에 따른 시료의 순간 투과도를 잡금 증폭기를 사용하여 측정하였다. 이 속도분광기를 사용하여 측정된 순간 흡광 및 바닥 상태의 표백 재생 속도 곡선들을 보여주었다. 단일 파장에서 발광 또는 비발광 계의 순간 흡광 혹은 바닥 상태의 표백 재생의 아주 좋은 속도 곡선을 얻을 수 있었다.

  • PDF

Multiple Order Diffractions by Laser-Induced Transient Grating in Nematic MBBA Film

  • 김성규;김학진
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권6호
    • /
    • pp.705-711
    • /
    • 1999
  • The laser-induced transient grating method is applied to study the dynamics of the nematic MBBA film. The nanosecond laser pulses of 355 nm are used to make the transient grating and the cw He-Ne laser of 633 nm is used to probe the dynamics. Strong multiple order diffractions are observed at high nematic temperatures. The reordering process induced by the phototransformed state, which is the locally melted state from the nematic sample, is attributed to the main origin of the multiple order diffractions from the nematic MBBA. The characteristics of the multiple order gratings are discussed with the grating profiles simulated from the multiple diffraction signals.

펄스모듈레이션 된 고주파 플라즈마의 시변특성 (Time-dependent Characteristics of Pulse Modulated rf Plasma)

  • 이선홍;박정후;이호준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권11호
    • /
    • pp.566-571
    • /
    • 2004
  • Pulse modulation technique provide additional controling method for electron temperature and density in rf and microwave processing plasma. Transient characteristics of electron density and temperature have been measured in pulse modulated rf inductively coupled argon plasma using simple probe circuit. Electron temperature relaxation is clearly identified in the after glow stage. Controllability of average electron temperature and density depends on the modulation frequency and duty ratio. Numerical calculation of time-dependent electron density and temperature have been performed based on the global model. It has been shown that simple langmuir probe measurement method used for continuous plasma is also applicable to time-dependent measurement of pulse modulated plasma.

비정상면열원법을 이용한 지반물질의 열전달 특성 평가 (Thermal measurement of Geomaterials using Transient Plane Source)

  • 김영진;윤태섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 2차
    • /
    • pp.45-52
    • /
    • 2010
  • Thermal properties of geomaterial are overlooked with other geomechanical properties. The transient line-source (TLS) method is one of the most used testing methods for measuring the thermal conductivity (K) and thermal diffusivity ($\alpha$) of materials. But more recently, Transient Plane-Source method was developed to measure these. It has several advantage of comparing with TSL method, but there has not been documented application in geomaterial. A Resistance Temperature Detector is used to construct sensor. For durability of Probe, Adopt a new technique that two probes are bonded in exact matching. For standard materials, such as glycerin, and ice the measured K and a values of these materials were generally within 2-5% from the standard values in the literature. This document present to evaluate the thermal properties of geomaterials and its application was tested for varying degree of saturation using the Transient Plane Source method. The result of this study suggests that it is an comparatively accurate method for simultaneously measuring thermal conductivity and thermal diffusivity and can identify the feasibility to geomaterial.

  • PDF

과도 액정 기법을 이용한 와동발생기 하류의 유동장 및 열전달 측정 (Detailed Measurement of Flow and Heat Transfer Downstream of Rectanglar Vortex Generators Using a Transient Liquid Crystal Technique)

  • 홍철현;양장식;이기백
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1618-1629
    • /
    • 2003
  • The effects of the interaction between flow field and heat transfer caused by the longitudinal vortices are experimentally investigated using a five hole probe and a transient liquid crystal technique. The test facility consists of a wind tunnel with vortex generators protruding from a bottom surface and a mesh heater. In order to control the strength of the longitudinal vortices, the angle of attack of vortex generators used in the present experiment is 20$^{\circ}$, and the spacing between the vortex generators is 25mm. The height and cord length of the vortex generator is 20mm and 50mm, respectively. Three-component mean velocity measurements are made using a f-hole probe system, and the surface temperature distribution is measured by the hue capturing method using a transient liquid crystal technique. The transient liquid crystal technique in measuring heat transfer has become one of the most effective ways in determining the full surface distributions of heat transfer coefficients. The key point of this technique is to convert the inlet flow temperature into an exponential temperature profile using the mesh heater set up in the wind tunnel. The conclusions obtained in the present experiment are as follows: The two maximum heat transfer values exist over the whole domain, and as the longitudinal vortices move to the farther downstream region, these peak values show the decreasing trends. These trends are also observed in the experimental results of other researchers to have used the uniform heat flux method.

Fast Measurement using Wave-Cutoff Method

  • 서상훈;나병근;유광호;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF