Performance Characteristics of a Liquid-Metal Heat Pipe for igh-temperature Solar Thermal Devices Depending on the Operating Conditions (고온 태양열기기용 액체금속 히트파이프의 작동조건에 따른 성능 특성)

  • Park, Cheol-Min;Lee, Jung-Ryun;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.247-250
    • /
    • 2009
  • Sodium heat pipe for high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Total length of the heat pipe was 650 mm and the outer diameter was 12.7 mm. Thermal performance was compared experimentally for two different cooling methods of the forced and the natural convection cooling in the heat pipe condenser. During the experiment, the maximum temperature was about 1300K, and different cooling methods were applied to the condenser region to charge the operating temperature. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and operating temperature.

  • PDF

Exergy analysis of heat pump in consideration of its dynamic response (동특성을 고려한 열펌프의 엑서지 해석)

  • 장기태;남관우;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.155-164
    • /
    • 1998
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the dynamic response of heat pump. First, a basic heat pump cycle is examined at steady state to show the general trends of exergy changes in each process of the cycle. Entropy generation issue in the exchangers is discussed to optimize the heat pump cycle. Second, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Third, the exergy destruction rate associated with the ON/OFF operations of the heat pump is calculated by simulating the thermodynamic states of the condenser and the evaporator. The inefficiency of the ON/OFF operation during the transient period is quantitatively revealed by the exergy analysis.

  • PDF

OLED Power Driving Simulation Using Impedance Spectroscopy

  • Kong, Ung-Gul;Hyun, Seok-Hoon;Yoon, Chul-Oh
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.32-35
    • /
    • 2003
  • Nonlinear parameterization of OLED device from measurements of bias dependence of impedance spectra and parameter extraction using Levenberg-Marquardt complex nonlinear least square regression algorithm based on resistor-capacitor equivalent circuit model enables computer simulation of OLED power driving characteristics in forms of square-wave or sinusoidal output signal at arbitrary conditions. We introduce developed OLED power driving simulation software and discuss transient responses in voltage-or current-controlled operations as well as nonlinear characteristics of OLED, by presenting both the simulation and experimental results. This OLED simulation technique using impedance spectroscopy is extremely useful in predicting performance of the nonlinear device, especially in time-domain analysis of device operation.

  • PDF

A Study on Water Hammer Phenomena in Piping Systems of Buildings (건축배관시스템 내에서의 수격현상에 관한 실험적 연구)

  • 한화택;김종만;김종필
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2251-2256
    • /
    • 1994
  • An experimental study was conducted on water hammer phenomena generated by quick valve operations in piping systems of buildings. Transient water hammer pressure waves were measured for three different types of valves, i. e. a ball valve, a solenoid valve, and on one-touch valve. The effects of flow rate and valve closing time on the maximum water hammer pressure were investigated. Based on the experimental results, general design recommendations were provided to prevent water hammer phenomena in piping systems of high-rise apartment buildings.

Front Tracking Finite Element Analysis of Heat Transfer in Spray Forming Process (경계추적 유한요소법을 이용한 분무성형공정에서의 열전달 해석)

  • 장동훈;강신일
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.148-152
    • /
    • 1997
  • A numerical method is presented to predict and analyze the shape and the temperature history of a growing billet produced form the "spray forming" which is a fairly new near net-shape manufacturing process. It is important to understand the mechanism of billet growing and the cooling history of the spray deposited body, because one can obtain a billet with the desired final shape without secondary operations by accurate control of the billet shape and, moreover, growing velocity together with the cooling rate define the microstructure of the final formed product. In the present study, a theoretical model is first established to predict the shape of the billet and next the transient axisymmetric heat conduction problem with growing domain is solved using the so called "front tracking finite element technique".ent technique".uot;.

  • PDF

High Performance Current Control Scheme of IPM Motors with Physical Limitation of Stator Voltages (전압 제한을 고려한 매입형 영구자석 전동기의 고성능 전류 제어)

  • Lee, Joo-Young;Ahn, Byoung-Gyo;Ha, In-Joong;Song, In-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.72-76
    • /
    • 1997
  • Interior permanent magnet synchronous motors can be applied to applications requiring wide-speed operation. The current control scheme of an interior permanent magnet synchronous (IPM) motor via feedback linearizing technique is proposed. As the available voltage controlling the armature current is small in transient operations and/or flux-weakening region, the current control performance can be deteriorated. The high performance overmodulation strategy is also proposed to improve the current responses. The control performances are confirmed by simulations.

  • PDF

A Novel Current-fed Energy Recovery Sustaining Driver for Plasma Display Panel (PDP) (PDP를 위한 새로운 전류원 타입의 에너지 회수 및 방전유지 회로)

  • Han S.K.;Moon G.W.;Youn M.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.755-760
    • /
    • 2003
  • A novel current-fed energy-recovery sustaining driver (CFERSD) for a PDP is proposed in this paper. Its main idea is to recover the energy stored in the PDP or to inject the input source energy to the PDP by using the current source built-up in the energy recovery inductor. This method provides zero-voltage-switching (ZVS) of all main power switches, the reduction of EMI, and more improved operational voltage margins with the aid of the discharge current compensation. In addition, since the current flowing through the energy recovery inductor can compensate the plasma discharge current flowing through the conducting power switches, the current stress through all main power switches can be considerably reduced. Furthermore, it features a low conduction loss and fast transient time. Operations, features and design considerations are presented and verified experimentally on a 1020X106mm sized PDP, 50kHz-switching frequency, and sustaining voltage 140V based prototype.

  • PDF

A Study on Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torch

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.242-243
    • /
    • 2010
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torch. Series resonant half-bridge topology is presented to be a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. The plasma torch rated for 3MW, 2kA and having the physical size of 1m long is selected to be a high enthalpy source in waste disposal system. The steady-state and transient operations of plasma torch are simulated. The parameters of Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. Circuit simulation waveform shows that the ripple of arc current can be maintained within ${\pm}10%$ of its rated value under the existence of load disturbance. This power conversion configuration provides high enough ignition voltage around 5KA during ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

  • PDF

Study of a SEPIC-input Self-driven Active Clamp ZVS Converter

  • Cao, Guo-En;Kim, Hee-Jun
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.202-215
    • /
    • 2013
  • This paper proposes a SEPIC-input, self-driven, active clamp ZVS converter, where an auxiliary winding and a RC delay circuit are employed to drive the active clamp switch and to achieve asymmetrical duty control without any other extra circuits. Based on the fixed dead time and the resonance between capacitors and inductors, both the main switch and the auxiliary switch can rule the ZVS operation. Detailed operation modes are presented to illustrate the self-driven and ZVS principles. Furthermore, an accurate state-space model and the transfer functions of the proposed converter have been presented and analyzed in order to optimize dynamic performance. The model provides efficient prediction of converter operations. Experimental results, based on a prototype with 80V input and 15V/20A output, are discussed to verify the transient and steady performance of the proposed converter.

Bidirectional Quasi-Cuk DC/DC Converter with Reduced Voltage Stress on Capacitor and Capability of Changing the Output Polarity

  • Asl, Elias Shokati;Sabahi, Mehran
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1108-1113
    • /
    • 2017
  • In this paper, a bidirectional topology for quasi-Cuk dc/dc converter with capability of zero-voltage and zero-current-switching (ZVZCS) is proposed. The bidirectional quasi-Cuk (BQ-Cuk) converter has different voltage and current transfer ratio, reduced voltage stress on capacitor and capability of changing the output polarity in comparison with conventional bidirectional Cuk converter. In this paper, steady-state analysis of the quasi-Cuk converter with capability of ZVZCS in turn-on is presented. Then, critical inductances for transient from this operation to two new operations are calculated. Next, besides values designing of used elements, maximum and minimum value of their current and voltage are calculated. Finally, experimental results to verify the accuracy of the proposed converter in different operating modes are presented.