• 제목/요약/키워드: Transient Fault

검색결과 419건 처리시간 0.029초

아크지락사고에 대한 사고 판별 및 적응 재폐로 기법 (Identification of Arcing Fault and Development of An Adaptive Reclosing Technique about Arcing Ground Fault)

  • 김현홍;추성호;채명석;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.354-356
    • /
    • 2006
  • This paper presents a new one-terminal numerical algorithm for fault location estimation and for faults recognition. The proposed algorithm are derived for the case of most frequent single-phase line to ground fault in the time domain. The arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent of transient. In this paper the algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm the Electro-Magnetic Transient Program(EMTP/ATP) is used.

  • PDF

아크 지락 사고에 대한 사고거리추정 및 사고판별에 관한 자동 적응자동재폐로 기법 (Adaptive AutoReclosure Technique for Fault Location Estimation and Fault Recognition about Arcing Ground Fault)

  • 김현홍;이찬주;채명석;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.283-285
    • /
    • 2005
  • This paper presents a new two-terminal numerical algorithm for fault location estimation and for faults recognition using the synchronized phasor in time-domain. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. Also the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. In this paper the algorithm is given and estimated using DFT(Discrete Fourier Transform) and the LES(Least Error Squares Method). The algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm, the Electro-Magnetic Transient Program(EMTP/ATP) and MATLAB is used.

  • PDF

THD를 이용한 적응형 재폐로 방법 적용 시 과도 안정도에 미치는 영향 (Effect on Transient Stability According to Application of Adaptive Autoreclosure Using THD)

  • 강성범;서훈철;이명희;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.201-202
    • /
    • 2011
  • This paper compares the effect on transient stability by according to application of adaptive autoreclouse using THD with the one of conventional autoreclosure. These two autoreclousure methods are modeled by EMTP/MODELS and simulated according to various fault locations and fault clearing times. This paper analyzes transient stability using simulation results.

  • PDF

비동기 순차 머신의 비-기본모드에서 발생하는 고장 극복을 위한 교정 제어 (Fault-Tolerant Corrective Control for Non-fundamental Mode Faults in Asynchronous Sequential Machines)

  • 양정민;곽성우
    • 전기전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.727-734
    • /
    • 2020
  • 본 논문은 과도 고장을 가지는 비동기 순차 머신에 대한 내고장성 교정 제어를 다룬다. 본 논문에서 다루는 고장은 머신이 과도 상태 천이를 거칠 때 발현할 수 있으므로 비-기본 모드(non-fundamental mode)에서 원하지 않는 상태 천이를 일으킨다. 본 논문에서는 비동기 순차 머신의 비-기본 모드에서 발생하는 과도 고장을 탐지하고 극복할 수 있는 새로운 내고장성 제어 시스템을 제안한다. 교정 제어 이론의 틀 안에서 내고장성 제어기의 존재 조건과 설계 과정을 제시한다. 또한 제안된 제어 시스템의 효용성을 검증하기 위해 FPGA 실험을 실시한다.

지중송전계통에서 Wavelet 변환과 퍼지추론을 이용한 고장종류판별 및 고장점 추정에 관한 연구 (A Study on the Fault Discrimination and Location Algorithm in Underground Transmission Systems Using Wavelet Transform and Fuzzy Inference)

  • 박재홍;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권3호
    • /
    • pp.116-122
    • /
    • 2006
  • The underground transmission lines is continuously expanded in power systems. Therefore the fault of underground transmission lines are increased every year because of the complication of systems. However the studies dealing with fault location in the case of the underground transmission lines are rarely reported except for few papers using traveling wave method and calculating underground cable impedance. This paper describes the algorithm using fuzzy system and travelling wave method in the underground transmission line. Fuzzy inference is used for fault discrimination. To organize fuzzy algorithm, it is important to select target data reflecting various underground transmission line transient states. These data are made of voltage and average of RMS value on zero sequence current within one cycle after fault occurrence. Travelling wave based on wavelet transform is used for fault location. In this paper, a variety of underground transmission line transient states are simulated by EMTP/ATPDraw and Matlab. The input which is used to fault location algorithm are Detail 1(D1) coefficients of differential current. D1 coefficients are obtained by wavelet transform. As a result of applying the fuzzy inference and travelling wave based on wavelet transform, fault discrimination is correctly distinguished within 1/2 cycle after fault occurrence and fault location is comparatively correct.

동시 결함 검출 기능이 있는 실시간 제어 시스템의 결함 허용성을 위한 적응형 체크포인팅 기법 (An Adaptive Checkpointing Scheme for Fault Tolerance of Real-Time Control Systems with Concurrent Fault Detection)

  • 류상문
    • 제어로봇시스템학회논문지
    • /
    • 제17권1호
    • /
    • pp.72-77
    • /
    • 2011
  • The checkpointing scheme is a well-known technique to cope with transient faults in digital systems. This paper proposes an adaptive checkpointing scheme for the reliability improvement of real-time control systems with concurrent fault detection capability. With concurrent fault detection capability the effect of transient faults are assumed to be detected with no latency. The proposed adaptive checkpointing scheme is based on the reliability analysis of an equidistant checkpointing scheme. Numerical data show the proposed adaptive scheme outperforms the equidistant scheme from a reliability point of view.

발전기시스템의 고정자보호 IED를 위한 개선된 알고리즘 (Advanced Algorithm for IED of Stator Winding Protection of Generator System)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.91-95
    • /
    • 2008
  • The large AC generator fault may lead to large impacts or perturbations in power system. The generator protection control systems in Korea have been imported and operated through a turn-key from overseas entirely. Therefore a study of the generator protection field has in urgent need for a stable operation of the imported goods. In present, the algorithm using the current ratio differential relaying based DFT for stator winding protection or a fault detection had been applied that of internal fault protection of a generator. the DFT used for the analysis of transient state signal conventionally had defects losing a time information in the course of transforming a target signal to frequency domain. In this paper, the discrete wavelet transform (DWT) was applied a fault detection of the generator being superior to a transient state signal analysis and being easy to real time realization. The fault signals after executing a terminal fault modeling collect using a MATLAB package, and calculate the wavelet coefficients through the process of a muiti-level decomposition (MLD). The proposed algorithm for a fault detection using the Daubechies WT (wavelet transform) was executed with a C language and the commend line function for the real time realization after analyzing MATLAB's graphical interface. The advanced technique had improved faster a speed of fault discrimination than a conventional DFR based on DFT.

3상 일괄형 Pipe Type HTS 케이블의 정상 및 과도상태 해석 (Steady and Transient State Analysis on Three Phase-in One Enclosure Type HTS Cable)

  • 장주영;이종범;김용갑
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1748-1753
    • /
    • 2010
  • This paper suggests an improved technique to establish the modeling regarding steady and transient state on three phase-in one cryostat type HTS(High Temperature Superconducting) cable. The proposed modeling is established using EMTP/ATPDraw and TACS and MODELS provided by that. It has higher accuracy than the conventional method, as the actual HTS cable is modelled. Steady and transient state analysis performed by EMTP/ATPDraw calculate the current of conductor, shield and former, respectively. In case of the transient state modeled quench state occurred by a single line-to-ground fault, current of conductor shield and former are also calculated, respectively. Especially, various fault resistances and angles are considered to improve the reliability during transient state analysis. Analysis results reveal that the proposed technique improves the accuracy of modeling.

발전기의 사고 시뮬레이션과 분석 (Fault Simulation and Analysis of Generator)

  • 박철원;오용택
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.151-158
    • /
    • 2013
  • Large generator of power plant is very important. In order to protect large generator from faults, digital protective relay or IED is required. However, all protective relays for generators of the domestic power plant are operated by foreign products. And now, for technological independence from foreign and improvement of import substitution effect, IEDs using domestic technology are being developed. To evaluate performance of developing next-generation power devices, the study of the dynamic characteristics of the power plant, generator system modeling, fault simulation and analysis, should be considered. Specially, To obtain IEEE Standards COMTRADE format for relay operation test, generator system modeling and fault simulation using PSCAD/EMTDC tools must be preceded. Until now, a complete modeling of generator internal windings and fault simulation techniques dose not exist. In this paper, for evaluation performance of relay elements of developing IED, the generator system modeling and various faults simulation using PSCAD/EMTDC tools were performed. And then, the various transient phenomena through obtained relaying signal of developed modeling were analyzed.

Two Terminals Numerical Algorithm for Distance Protection, Fault Location and Acing Faults Recognition Based on Synchronized Phasors

  • Lee Chan-Joo;Park Jong-Bae;Shin Joong-Rin;Radojevic Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.35-41
    • /
    • 2006
  • This paper presents a new numerical algorithm for fault location estimation and for faults recognition based on the synchronized phasors. The proposed algorithm is based on the synchronized phasor measured from the synchronized PMUs installed at two-terminals of the transmission lines. In order to discriminate the fault type, the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. The results of the proposed algorithm testing through computer simulation are given.