• 제목/요약/키워드: Transformer losses

검색결과 172건 처리시간 0.021초

A Coupled Line Impedance Transformer for High Termination Impedance with a Bandpass Filtering Response

  • Kim, Phirun;Jeong, Yongchae
    • Journal of electromagnetic engineering and science
    • /
    • 제18권1호
    • /
    • pp.41-45
    • /
    • 2018
  • In this study, a short-ended coupled line with a short-circuit stub transmission line bandpass filtering impedance transformer is presented. The general designed equations are derived on the basis of circuit theory. The design curves are provided to examine the characteristic of the proposed impedance transformer. The proposed circuit is suitable for high termination impedance. To validate the design formulas, a $400-50{\Omega}$ impedance transformer is designed and fabricated at the operating center frequency ($f_0$) of 2.6 GHz. The measured results show a good agreement with the simulation. The measured insertion and return losses are 0.6 dB and 22.5 dB at $f_0$, respectively. The measured return loss is higher than 20 dB within the passband frequency of 2.51-2.7 GHz. Moreover, the stopband attenuation is higher than 25 dB from DC to 1.64 GHz of the lower stopband and from 3.12 GHz to 6.4 GHz of the higher stopband.

High Efficiency Alternating Current Driver for Capacitive Loads Using a Current-Balance Transformer

  • Baek, Jong-Bok;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제11권1호
    • /
    • pp.97-104
    • /
    • 2011
  • This paper proposes a new alternating current driving method for highly capacitive loads such as plasma display panels or piezoelectric actuators, etc. In the proposed scheme, a current balance transformer, which has two windings with the same turn-ratio, provides not only a resonance inductance for energy recovery but also a current balance among all of the switching devices of the driver for current stress reduction. The smaller conduction loss than conventional circuits occurs due to the dual conduction paths which are parallel each other in the current balance transformer. Also, the leakage inductances of the transformer are utilized as resonant inductors for energy recovery by the series resonance to the capacitive load. Furthermore, the resonance contributes to the small switching losses of the switching devices by soft-switching operation. To confirm the validity of the proposed circuit, prototype hardware with a 12-inch mercury-free flat fluorescent lamp is implemented. The experimental results are compared with a conventional energy-recovery circuit from the perspective of luminance performances.

유동대전(流動帶電)에 미치는 변압기(變壓器) 재질(材質)의 영향(影響) (Effect of Materials on Streaming Electrification in Transformer)

  • 권동진;강창구;곽희로;김재철;이덕철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.170-172
    • /
    • 1990
  • In a large power transformer, an insulating oil is forced to circulate for cooling the heat generated by the losses within the windings and core. When oil flows and rubs against various materials, including insulating paper and steel, electrostatic charges are separated at the interface of the oil and the solid material. This paper considers the polarity and the streaming electrification of the various materials which are used in transformer. As a result of this study, it is confirmed that the leakage current on the solid material, such as paper, is charged negative. On the other hand, the solid material, such as steel, is positively charged.

  • PDF

새로운 소프트 스위칭 FB DC-DC 컨버터 (Novel soft switching FB DC-DC converter)

  • 김은수;최해영;조기연;계문호;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.251-255
    • /
    • 1997
  • The conventional high frequency phase-shifted full bridge dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this paper provides a circulating current free type high frequency soft switching phase-shifted full bridge (FB) dc/dc converter with energy recovery snubber (ERS) attached at the secondary side of transformer. The energy recovery snubber (ERS) adopted in this study is consisted of three fast recovery diode(Ds1, DS2, Ds3), two resonant capacitor (Cs1, Cs2)

  • PDF

무접점 베터리 충전 장치용 Half-Bridge 직렬 공진 컨버터 분석 및 설계 (Analysis and Design of Half-Bridge Series Resonant Converter for Non-Contact Battery Charger)

  • 김창균;유정식;박종후;조보형;서동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2508-2511
    • /
    • 1999
  • A non-contact battery charger which transfers energy using magnetic field without any electrical contacts is designed using half-bridge series resonant converter. This converter utilizes series resonance to reduce the undesirable effect of large leakage inductance of the non-contact transformer and ZVS operation can reduce switching losses. In this paper. analysis and design procedure of half-bridge series resonant converter with non-contact transformer is presented. Input voltage is 85VAC ${\sim}$ 270VAC, output voltage and current is 4.1V and 800mA, respectively. Furthermore, a method for calculating the secondary current of the transformer to control battery charging current in constant current charging mode which is required for litium-ion battery is proposed and the performance is verified from experiments.

  • PDF

Class-E CMOS PAs for GSM Applications

  • Lee, Hong-Tak;Lee, Yu-Mi;Park, Chang-Kun;Hong, Song-Cheol
    • Journal of electromagnetic engineering and science
    • /
    • 제9권1호
    • /
    • pp.32-37
    • /
    • 2009
  • Various Class-E CMOS power amplifiers for GSM applications are presented. A stage-convertible transformer for a dual mode power amplifier is proposed to increase efficiency in the low-output power region. An integrated passive device(IPD) process is used to reduce combiner losses. A split secondary 1:2 transformer with IPD process is designed to obtain efficient and symmetric power combining. A quasi-four-pair structure of CMOS PA is also proposed to overcome the complexities of power combining.

영전압.영전류 스위칭 3 레벨 DC/DC 컨버터 (Zero-Voltage Zero-Current Switching Three Level DC/DC Converter)

  • 김은수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권12호
    • /
    • pp.682-690
    • /
    • 2002
  • The conventional three-level high frequency phase-shifted dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval.. Due to this circulating current and RMS current stress, conduction losses of transformer and switching devices increases. To alleviate these problems, we propose an improved three-level Zero Voltage and Zero Current Switching (ZVZCS) dc/dc converter using a tapped inductor, a snubber capacitor and two snubber diodes attached at the secondary side of transformer. The proposed ZVZCS converter is verified on a 7㎾, 30KHz experimental prototype.

Comparison of Power Loss and Magnetic Flux Distribution in Octagonal Wound Transformer Core Configurations

  • Cinar, Mehmet Aytac;Alboyaci, Bora;Sengul, Mehlika
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1290-1295
    • /
    • 2014
  • In this paper, various configurations of octagonal wound transformer core topology, which has previously proved advantages on conventional wound cores, are studied. Each configuration has different joint types and different placement of joint zones on the core. Magnetic flux distributions and power losses of each configuration are analyzed and compared. Comparisons are based on both 2D&3D finite element simulations and experimental studies. The results show that, joint types and their placements on the core cause local flux accumulations and dramatically affect power loss of the core.

개선된 영전압$\cdot$영전류 스위칭 3 레벨 DC/DC 컨버터 (An Improved ZVZCS Three-Level DC/DC Converter)

  • 김은수;최선호;박성수;박진영;양승철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2002
  • The conventional three-level high frequency phase-shifted dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due In this circulating current and RMS current stress, conduction losses of transformer and switching devices increases. To alleviate these problems, we propose an improved three-level Zero Voltage and Zero Current Switching (ZVZCS) dc/dc converter using a tapped inductor, a snubber capacitor and two snubber diodes attached at the secondary side of transformer The proposed ZVZCS converter is verified on a 7kW, 30kHz experimental prototype.

  • PDF

식물성 절연유의 유속과 BTA에 따른 유동대전 현상 연구 (Research of Flow Velocity and BTA According to the Streaming Electrification of Vegetable Insulating Oils)

  • 최순호;방정주;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.791-797
    • /
    • 2012
  • Mineral insulating oils are an important insulating materials in oil-filled transformer. However, the mineral oil is the cause of the environmental problem. The vegetable oils are substitutes for mineral oil because of its biodegradability characteristic. As large size and high rating of the transformer increases, the losses increase at a faster rate. So insulating oil is forced circulation in the oil-filled transformer by using oil pumps. The flow electrification occurs when insulating oil was forced to be circulated. To check the flow electrification, had conducted experiments varying factors. As a result, the streaming electrification could see the changes according to flow velocity, oil temperature and insulation materials.