유입변압기 오일필터링에 따른 유전정접 변화사례 고찰 (Example study of the dissipation factor change according to the oil filtering in large oil-filled transformer)

  • 공태식;김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2035_2036
    • /
    • 2009
  • This paper is purpose to understand the dissipation factor properties of the oil-filled large transformer according to the oil filtering. In order to know the insulation characteristic change by insulating oil filtering, we carried out the insulation diagnostic test for the same transformer before oil filtering and after. The insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, Especially we took notice of dissipation factor change, we analyzed and made a comparison of the two cases test result.

  • PDF

유중 가스 검출장치의 수소 가스 감지 특성에 관한 연구 (Study on $H_2$ Sensing Characteristics of Gas Extractor for Dissolved Gas in Oil)

  • 황규현;서호준;이동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1162-1165
    • /
    • 2004
  • In oil-filled enuipment such as transformers, partial discharge or local overheating will precede a final shutdown. Accompanied with such problems is a decomposition of insulating material into gases, which are dissolved into the transformer oil. The gases dissolved in oil can be separated with some membranes based on the differences in permeability of membranes to different gases. This paper discuss the permeability characteristics of several membranes for separation hydrogen gas in oil. With result of this paper, it may become possible to detect fault-related gases from transformer oil and predict incipient failures in the future.

  • PDF

UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정 (Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제35권3호
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

$SF_6$가스절연 변압기 ($SF_6$ Gas Insulated Transformer)

  • 조광제;홍기돈;하영식;조규복;노철웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.304-309
    • /
    • 1991
  • We introduce the trend, of several countries, to the gas insulated transformer recently coming into the spot light by the advantages of less weight, GIS-lization, low noise level and easiness to decrease environmental pollutions, and the insulating gases. the cooling media and the insulating materials used for transformer. Hereinafter, additively the design of proto type $SF_6$ gas insulated transformer (insulation, cooling), which was developed by us(HICO) from 1987. 2 through 1990. 3, the manufacturing processes(leak protection, pressure, drying of main body), the accessories, the protective system, the cooling system, the method and the results of test and the evaluation of economics compared with conventional oil-filled transformer are represented.

  • PDF

퍼지 알고리즘을 이용한 유중 변압기의 안전진단 및 평가에 관한 연구 (A Study on the Safty Diagnosis and Evaluation of Oil-immersed Transformer using fuzzy Algorithm)

  • 김영일
    • 전기학회논문지P
    • /
    • 제55권4호
    • /
    • pp.190-195
    • /
    • 2006
  • In this paper, safety algorithm of transformer is introduced for the sake of MV/LV distribution customers by using fuzzy theory. The current-carrying capacity of transformer is usually determined by the maximum temperature at which the transformer is permitted to operate. Overload of transformer has an effect on transformer utilization rate and maximum temperature rises as well as maximum ambient temperature of insulating materials. Therefore, we proposed the safety algorithm considering the overload of transformer and ambient temperature in this paper. We introduced the correlational equations between each parameters using experimental data of IEEE std C57.91-1995, and deduced the result using fuzzy reasoning. We guessed the safety algorithm making a diagnosis for the safety status of oil-immersed transformer.

전기 절연유 열화진단을 위한 3-단자식 전기용량 센서 개발 및 진단특성 평가 (Development and Evaluation of 3-terminal Type Capacitive Sensor for the Diagnosis of Electrical Insulating Oil)

  • 김주한;한상옥
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.476-482
    • /
    • 2009
  • This paper describes the development of capacitive sensor for the diagnosis of liquid dielectrics, which is widely used as the electrical insulating oil of transformer, circuit breaker, cable and etc. To survey the dielectric properties of the virgin and aged electrical insulating oils, we utilized the highly precise measuring system, using the principle of cross capacitance. The measured properties were used to determine the design factors of the sensor. Then the factors were optimized with the help of computational analysis. To evaluate diagnosis by the sensor, we performed accelerated thermal aging test about electrical insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. And to evaluate the hysteresis characteristics with the change of temperature, we constructed a testing system, which was composed with vacuum drying oven, oil chamber and measuring instruments, such as LCR meter, MUX and so forth. Through the results of this investigation, we confirmed the superior characteristics of the newly developed sensor.

개스분석에 의한 주상변압기의 예방진단에 관한 연구 -자외-가시선 흡수분광광도법에 의한 절연유의 열화도 측정- (A Study on Preventive Diagnosis of the Pole Transformer by Gas Analysis -Measurement of Aging of Insulating Oil by UV-Visible Spectrophotometric Method-)

  • 곽희로;남영우;윤영자;남궁미옥;이동준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권5호
    • /
    • pp.94-100
    • /
    • 1996
  • 자외- 가시선 흡수분광광도법을 적용하여 주상변압기 절연유의 판정기준을 제시하였다. 절연유가 열화하면 절연유의 전기적 특성치가 저하할 뿐만 아니라 흡광도값도 변하게 된다. tan$\delta$와 절연파괴전압과 같은 전기적 특성치를 흡광도값과 비교하여 흡광도값에 의한 절연유의 판정기분을 설정하였다. 흡광도값이 0.580 이하는 양호, 요주의는 0.580~0.900, 불량은 0.900이상이다. 자외-가시건 흡수분광광도법은 절연유의 열화분석에 적용할 수 있으며, 기존의 육안에 의한 절연유 검사 방법을 대체할 수 있을 것으로 기대된다. 그러나 분광광도법을 현장에 적용하려면 저렴하고 경량화된 휴대용 분광광도계의 개발이 필요하다.

  • PDF

유입변압기용 절연유의 절연파괴특성 (Electrical Breakdown Properties of Insulating Oils for oil-immersed transformer)

  • 이인성;신현택;이종필;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.605-608
    • /
    • 2001
  • With the intention of investigating the breakdown properties of oil-immersed transformer oils in temperature range of $20\sim100[^{\circ}C]$, we are made researches AC breakdown in the gap of $500\sim2500[{\mu}m]$. The classification for the physical properties of oil for oil-immersed transformer by FTIR and H-NMR experiments was confirmed to type of mineral oils. As the dependance of breakdown properties due to electrode gap length variation, breakdown voltage was found increasing according to the increase of gap, while dielectric strength was decreasing. As a result the characteristics for AC breakdown, It goes to prove that the breakdown voltage was increased to $90[^{\circ}C]$ but decreased over $90[^{\circ}C]$ in the temperature range. Also, breakdown voltage was found increasing in the increase of gap and the rising of temperature according to Weibull distribution.

  • PDF

전기절연유의 열화진단을 위한 정전용량 센서개발 (Development of Capacitive Sensor for the Diagnosis of Electrical Insulating Oil)

  • 최남호;김한준;김주한;김호수;한상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1609-1611
    • /
    • 2003
  • This paper presents the results on the development of capacitive sensor for the diagnosis of electrical insulating oil, widely used for power transformer. To survey the dielectric properties of the new and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate the operational and the hysteresis characteristics of the sensor, we constructed a test chamber, including dielectric property measuring system. Through the results we could confirm the superior characteristics of the newly developed sensor.

  • PDF

변압기절연재료의 유동대전특성에 미치는 제인자 연구 (A STUDY ON THE FACTOR OF STATIC ELECTRIFICATION ON TRANSFORMER INSULATING-MATERIALS)

  • 이숭녕;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1143-1145
    • /
    • 1995
  • In this paper, we measured leakage current that produced by static electrification at pressboard and insulating paper. We found that the leakage current increased as temperature increased, as oil velocity increased. The leakage current at pressboard is higher than that of insulating paper.

  • PDF