Comparison and Analysis of Domestic and Foreign Standard for electrical equipment installation of amusement park and ride (유원시설 전기설비 설치에 대한 국내외 규정 비교 분석)

  • Kim, Gi-Hyun;Kim, Chong-Min;Kim, Han-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.378-382
    • /
    • 2004
  • This paper gives information which is applied to install the electrical equipment of amusement park and ride. For analyzing the standard of electrical equipment installation, we research the related regulation of National Electrical Code(2002), IEC 60364-series and Technical standards for Electrical facilities of internal standard. Among electrical equipments of amusement park and ride, especially we study the transformer vaults, overcurrent protection and ground protection of electrical equipment. So we the furnished the installation information of transformer vaults, overcurrent and ground protection at amusement park and ride.

  • PDF

Future New Distribution System with Low voltage and Mass Capacity using HTS equipments (초전도기기를 적용한 미래 저압대용량 신 배전계통)

  • Yoon Jae Young;Kim Jong Yul;Lee Seung Ryul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.37-41
    • /
    • 2005
  • This paper describes the construction scheme of new distribution system using HTS(High Temperature Superconducting) power equipments such as cable, transformer and FCL(fault current limiter). At present, one of the most serious problems in distribution power system, especially for metropolitan complex city, is to obtain the ROW for cable line routes, space for downtown substations and satisfy the environmental protection caused by NIMBY phenomena. Unfortunately, it is expected that this situation will get more and more worse. As the HTS technology to apply in power system Is developed, HTS cable utilizing mass-capacity characteristic can be a useful countermeasure to overcome this problem. This paper describes the application methodology of 22.9kV HTS cable with low-voltage, mass-capacity characteristics replacing the 154kV conventional cable. By applying 22.9kV HTS cable, the HTS transformer with higher capacity for the reduction of space and transformer numbers of downtown substation is necessary. Also, if the leakage Impedance of HTS transformer is same as or lower than that of conventional transformer, the fault current of 22.9kV bus will increase because the HTS transformer capacity is larger than that of the conventional transformer. This means the parallel application of HTS-FCL to reduce the fault current in addition to the HTS cable and transformer can be necessary. With the basic construction scheme of new distribution system, this paper describes the future study points to realize this new distribution system using HTS equipments.

$SF_6$ Gas Insulated Transformer ($SF_6$가스절연 변압기)

  • Cho, G.J.;Cho, K.D.;Ha, Y.S.;Cho, K.B.;Noh, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.304-309
    • /
    • 1991
  • We introduce the trend, of several countries, to the gas insulated transformer recently coming into the spot light by the advantages of less weight, GIS-lization, low noise level and easiness to decrease environmental pollutions, and the insulating gases. the cooling media and the insulating materials used for transformer. Hereinafter, additively the design of proto type $SF_6$ gas insulated transformer (insulation, cooling), which was developed by us(HICO) from 1987. 2 through 1990. 3, the manufacturing processes(leak protection, pressure, drying of main body), the accessories, the protective system, the cooling system, the method and the results of test and the evaluation of economics compared with conventional oil-filled transformer are represented.

  • PDF

An analytical study on the Effect of High impedance Transformer to reduce Distribution Fault Current (변압기 임피던스 증가에 의한 배전계통의 고장전류 저감방안의 영향분석)

  • Lee, Hyun-Chul;Lee, Geun-Joon;Hyun, Ok-Bae;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.239_240
    • /
    • 2009
  • This paper presents the brief analytical study on 돋 effects of higher impedance transformer(HIT) to reduce distribution system fault current. With the increase of source and load capacity of power system, fault current of D/L is much more increased and, conventional protection equipment-such as sectionalizer and recloser, have to be replaced higher switching capacity. However, this replacements needs a lot of budget to utility. Increase of transformer impedance is can be a countermeasure in practical basis. This paper compares the voltage and fault current magnitude of both cases -%Zt=20% and %Zt2=33.3%(transformer capacity is 75/100MVA). The simulation results show that the steady state voltage of HIT is dropped 5~6% more in peak load, and fault current was decreased about 5kA by high impedance on transformer.

  • PDF

Internal Fault Classification in Transformer Windings using Combination of Discrete Wavelet-Transforms and Back-propagation Neural Networks

  • Ngaopitakkul Atthapol;Kunakorn Anantawat
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.365-371
    • /
    • 2006
  • This paper presents an algorithm based on a combination of Discrete Wavelet Transforms and neural networks for detection and classification of internal faults in a two-winding three-phase transformer. Fault conditions of the transformer are simulated using ATP/EMTP in order to obtain current signals. The training process for the neural network and fault diagnosis decision are implemented using toolboxes on MATLAB/Simulink. Various cases and fault types based on Thailand electricity transmission and distribution systems are studied to verify the validity of the algorithm. It is found that the proposed method gives a satisfactory accuracy, and will be particularly useful in a development of a modern differential relay for a transformer protection scheme.

Flux Linkages Ratio-Based Transformer Protection (쇄교자속비를 이용한 변압기 보호)

  • 강용철;이병은;김은숙;원성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.655-660
    • /
    • 2003
  • This paper describes a transformer protective relaying algorithm based on the ratio of increments of flux linkages (RIFL) of the primary and secondary windings. The algorithm uses integration approximation. The RIFL is equal to the turns ratio for all operating conditions except for an internal fault. For a single-phase transformer and a Y-Y transformer, the increments of flux linkages (IFL) are calculated. For a Y-$\Delta$ transformer, the difference of IFL are calculated to use the line currents rather than the delta winding currents, which are unavailable. Their ratios are compared with the turns ratio. The comparative study between the proposed and conventional differentiation approximation methods was conducted. The test results show that the algorithm reduces the approximation errors of the conventional methods.

Analyses of Transformer Characteristics for Current Differential Protective Relaying (차동전류 보호계전을 위한 변압기 특성분석)

  • Kim, Myeong-Cheol;Kang, Sang-Hee;Lee, Seung-Jae;Kim, Ki-Hwa;Kim, Il-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.671-673
    • /
    • 1996
  • Simulation methods using EMTP to analyze power transformer transient characteristics and their interesting results are presented in this paper. Because of the transformer saturation including initial inrush, the conventional current differential relay with harmonic restraint module does not provide a clear distinction between internal faults and other conditions. Providing the bases to develop a new relaying concept for power transformer protection, transformer nonlinear transient characteristics are analyzed.

  • PDF

A Study on Detection Algorithm of Open Phase Fault in Grid-Connected Transformer for PV System (태양광전원 연계용변압기의 결상사고 검출 알고리즘에 관한 연구)

  • Kang, Kab-Seok;Tae, Dong-Hyun;Lee, Hu-Dong;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.22-33
    • /
    • 2021
  • In the case of open phase faults caused by the disconnection of distribution feeders interconnected to a PV system, many problems can occur depending on the core type and wiring method of the grid-connected transformers. Moreover, open phase faults are difficult to detect because the open phase voltage of the existing protection relay (Open Phase Relay (47)) can be maintained, even though a disconnection fault occurred, depending on the wiring method and the iron core type of the grid-connected transformer for a PV system. Therefore, this paper proposes a novel algorithm to detect open phase faults by comparing the currents and phases between the primary and secondary sides of a grid-connected transformer. In addition, this paper presents the modeling of a distribution system and protection devices for detecting open phase faults using PSCAD/EMTDC S/W, and implements a test protection device for detecting open phase faults based on the above-mentioned modeling. The simulation and test results confirmed that the proposed algorithm is useful for detecting open phase faults according to the wiring method and iron core type of grid-connected transformer for a PV system because operation slope and unbalance rate of the primary current exceed the setting value (30[%]) of the protection device.

Three-Winning Transformer Protection Based on Flux Linkage Ratio (쇄교자속비를 이용한 3권선 변압기 보호)

  • 강용철;이병은;김은숙;원성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.375-381
    • /
    • 2004
  • This paper describes a three-winding transformer protective relaying algorithm based on the ratio of increments of flux linkages (RIFL). To minimize the approximation errors, the algorithm uses integration approximation. The RIFL of the two windings is equal to the turns ratio for all operating conditions except for an internal fault. For a single-phase and three-phase transformer containing the wye-connected windings, the increments of flux linkages (IFL) are calculated. For a three-phase transformer containing the delta-connected windings, the difference of IFL between the two phases are calculated to use the line currents, because the winding currents are practically unavailable. Their ratios are compared with the turns ratio. The comparative study between the proposed and differential approximation methods was conducted. The test results show that the algorithm can reduce the errors resulting from the conventional methods.

Development of Feeder Automation Software Considering the Diversity Events of Distribution System (배전계통의 다양한 이벤트들을 고려한 선로자동화 소프트웨어 개발)

  • Ko, Yun-Seok;Kim, Yun-Jib;Bak, Young-Gu;Lee, Kee-Seo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.307-309
    • /
    • 2002
  • This paper proposes an expert system, which is able to determine the problem-solving strategy for diversity events occurred on the distribution system. The events include events related to the fault, scheduled outage and optimal operating task such as feeder line fault, line scheduled outage, line overload, system load balancing, system loss minimization, main transformer fault, main transformer scheduled outage, main transformer overload, main transformer protection control. The expert system enhances the reliability of software designed by the integrated concept for the diversity events.

  • PDF