• Title/Summary/Keyword: Transformer Oil-paper

Search Result 235, Processing Time 1.171 seconds

변압기(變壓器) 절연유(絶緣油) 열화(劣化)센서의 특성연구(特性硏究) (A study on the characteristics of degradation sensor for transformer insulation oil)

  • 전영갑;선종호;강동식;김문덕;권동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1765-1768
    • /
    • 1996
  • It is well known that the degradation transformer oil is mainly effected to the failure of transformer. In this paper it is discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor composed with base ring, electrodes and porous ceramic passed through the transformer oil and checked the transformer oil condition with sensor's leakage current. It is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts it is examined the characteristics of V-T-I and DC 2 KV and other examinations. It is verified that ionized transformer caused by the expansion of oil temperature increase in the leakage current of porous ceramic sensor. It is certificated that the leakage current of other parts of porous ceramic is very small (about 2 %) than the porous ceramic and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

변압기 열열화 모의 고장어 대한 유중가스 분포연구 (A study on gas dissolved distribution in oil for simulated transformer thermal faults)

  • 선종호;이상화;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1800-1802
    • /
    • 2003
  • This paper describes a study on gas dissolved distribution in oil for simulated transformer thermal faults. Experimental chamber was setup for simulation of transformer thermal faults or discharge in oil with or without insulation paper. The experimental results showed that dissolved gases in oil excluding the paper did not evolved upto $150^{\circ}C$. Hereafter the planned gas dissolved analysis will be continuously carried out for transformer fault conditions with or without insulation paper related to water absorption, arc and partial discharge.

  • PDF

전력용 변압기의 열화에 의해 생성된 부산물의 분석 (Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers)

  • 김재훈;한상옥
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

변압기 절연물의 열화에 따른 화화적 특성 (Chemical Characteristics of Transformer Insulations by the Thermal Aging)

  • 김재훈;이원영;이병성;이세현;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1912-1914
    • /
    • 2005
  • The electrical, chemical and mechanical characteristics in transformer insulations are changed due to thermal stress. It is known that characteristics of transformer insulations is deteriorated such as decrease of dielectric strength, deterioration of dielectric constant and tensile strength of paper as transformer oil and paper are aged by thermal stress. Furthermore, chemical characteristics of them are deteriorated as like increment of moisture contents and dissolved by-products in oil, etc. In this paper we have been investigated chemical characteristics of transformer by accelerated thermal aging. For this working we have made experimental test cell and aged at a temperature up to $140^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. For analysis we used Karl-Fisher titration method and high performance liquid chromatography (HPLC).

  • PDF

변압기 절연유의 물성치 변화에 따른 온도특성해석 (Temperature Characteristic Analysis according to Variation of Properties of Transformer Insulating Oil)

  • 김지호;이욱
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.327-332
    • /
    • 2014
  • In this paper, the temperature distribution according to the property change of the insulating oil of the power transformer and max temperature were predicted through the ductility interpretation which heat-flow is coupled. By using CFD (Computation Fluid Dynamics) for the interpretation, the temperature distribution of 154kV the class single phase power transformer was predicted. The power loss causing the temperature rise of the transformer was changed to the heat source and we used as the input value for the heat-flow analysis. The temperature distribution was predicted according to the change of the density, specific heat, thermal conductivity and viscosity, that is the ingredient having an effect on the temperature rise of the transformer oil. The mineral oil of 4 kinds used in domestic and international based on the interpreted result was selected and the temperature distribution according to each load and Hot Spot temperature was predicted.

초음파 측정에 의한 변압기내 부분방전 위치측정 (Location of Partial Discharge in Oil Transformer by means of Ultrasonic measurement)

  • 곽희로;전희종;김재철;황선주;윤용한;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.415-418
    • /
    • 1991
  • This paper described an instrument for the detection and geometric location of partial discharge(PD) sources in oil transformer. This instrument measures electric current pulse and ultrasonic pulse simultaneously in order to determine the geometric location of PD in transformer. Laboratory experiment systems are made for detection and location of PD in oil transformer. It was observed that there are effects of the barrier, such as insulation papers, silicon steel plate and actual transformer with location and detection of PD in model transformer. Through the laboratory actual test, it was clarified that this measurement device could be used satisfactorily for location of pd in oil transformer.

  • PDF

최상부 유온 상승 특성을 이용한 100kVA 이하 유입식 배전용 변압기의 과부하 판정 기준 (Overload Criterion of Mineral-Oil-immersed Distribution Transformers Rated 100kVA and Less Using the Characteristics of Top-Oil Temperature Rising)

  • 윤상윤;김재철;박창호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.559-567
    • /
    • 2002
  • This paper presents the general recommendations for the overload criterions of mineral-oil-immersed distribution transformers rated 100kVA and less. For this purpose, we analyze the characteristics of top-oil temperature rising for mineral-oil-immersed power distribution transformer rated 100kVA and less, manufactured in Korea, In order to analyze the characteristics of top-oil temperature rising due to the distribution transformer loading, we performed experiments at KERI (Korea Electrical Research Institute) from December 2000 to May 2001. The restraint of ambient temperatures for the experiment results is solved using the results of foreign standards. Finally, we present the overload criterions of distribution transformer for summer and winter season, respectively.

절연유(絶緣油) 열화(劣化)센서 특성(特性) 연구(硏究) (A Study on the characteristics of degradation sensor for insulation oil)

  • 전영갑;선종호;강동식;주병수;윤진열;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1371-1374
    • /
    • 1995
  • It is well known that the degradation of transformer oil conseqently lead to the failure of transformer. This paper discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor is composed of base ring, electrodes and porous ceramic, passed through the transformer oil and checks the transformer oil condition through sensor's leakage current. So it is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts the characteristics of V-T-I and DC 2 KV and other examinations were performed. It is verified that ionized transformer oil caused by the expansion of temperature increases in the leakage current of porous ceramic sensor. It is certification that the leakage current of other parts of porous ceramic is very small(about 2%) compared with the porous ceramic body and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

Sagnac형 광섬유 배열센서를 이용한 유증 음답 탐지 연구 (Investigation of the Acoustic Detection in Transformer Oil Using Sagnac Fiber Optic Sensor Array)

  • 이종길;이승홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.533-534
    • /
    • 2010
  • Fiber optic sensor has bee widely used in the industrial applications. For the application of acoustic detection of the high voltage electric transformer Sagnac interferometer can be used. In this paper several different materials of mandrel were used in the fiber sensor array. Based on the transformer oil fiber optic sensor is more sensitive than in the air.

  • PDF

식물성절연유의 주상변압기 적용 연구 (Study on Vegetable Oil Application of the Pole Transformer)

  • 곽동순;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.169-171
    • /
    • 2009
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. For development of the environmental-friendly pole transformer using vegetable oil, we discussed the insulation construction of the transformer and the dielectric characteristics of the Nomex insulation paper in vegetable oil. Based on the experimental data, the insulation of the transformer is designed.

  • PDF