• Title/Summary/Keyword: Transfer unit

Search Result 847, Processing Time 0.035 seconds

Development of Projectile Transfer System to Prevent Musculoskeletal Problems (근골격계 질환 예방을 위한 포탄 이송장치의 개발)

  • Park, Sung Ho;Lee, Hae Suk
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.6
    • /
    • pp.551-558
    • /
    • 2015
  • The purpose of this paper is to investigate the development of mechanical projectile transfer system to prevent musculoskeletal problems in the firing test range. Prior to 2010, the projectile has been transferred from the worktable to the loading device of 155mm K9 fixed-type artillery by manual. Because the amount of firing test has been increased drastically since 2010, two types of mechanical projectile transfer system were developed to prevent musculoskeletal problems. The NIOSH lift equation and the working posture assessment system such as OWAS, RULA and REBA were used to evaluate the appropriacy of working weight and posture by manual transfer of projectile. The configuration and operation procedure of projectile transfer systems which were developed to improve work efficacy and to reduce the burden of manual transferring were described. The improvements were assessed by the number of processes, the tact time and the working posture assessment for operation of this system by comparing to the manual transfer of projectile.

A Novel Receiver Sensing Scheme for Capacitive Power Transfer System (전계결합 무선전력전송의 수신부 감지 방법)

  • Jeong, Chae-Ho;Im, Hwi-Yeol;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.62-65
    • /
    • 2019
  • Wireless power transfer systems require an algorithm to determine the presence of the target object for mitigating standby power and safety issues. Although many schemes that sense various external objects have been actively proposed for inductive power transfer systems, not many studies on capacitive power transfer systems have been conducted compared with those on inductive power transfer systems. This study proposes a target object detection algorithm by monitoring the capacitance in transmitter-side electrodes without additional pressure sensors or distance sensors. The proposed algorithm determines the presence of a target object by monitoring the change in capacitance in transmitter-side electrodes using the step pulse of the microcontroller unit. The algorithm is verified by two step processes. First, the performance in capacitance measurement is compared with that of an LCR meter. Then, the verification is conducted in a 5-W capacitive power transfer hardware. Experimental result shows that the interelectrode capacitance increases by 6 times when the target object is fully aligned. Thus, the proposed scheme can successfully detect the presence of the target object.

Development of a Oil-Cooler for High-Speed CNC Lathe (고속 CNC선반용 공랭식 오일 냉각기 개발)

  • Yum, Man-Oh
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.4
    • /
    • pp.11-16
    • /
    • 2003
  • Recently, CNC lathe is in need of higher speed for precision works. So more intensive and compact heat exchanger is necessary to cool down the heat in short time from drills and works during high speed working. In this study, to increase heat transfer coefficient per unit volume, inner groove tube is designed and compact oil cooler, 57% volume of conventional type, is manufactured. The heat transfer performance is experimented and is compared with the performance of conventional type.

  • PDF

A development of simulator for satellite power system (인공위성용 전력시스템 시뮬레이텨 개발)

  • 김영태;김희준
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.193-201
    • /
    • 1996
  • The space power system for communication satellite which employs the direct energy transfer (DET) method consists of solar array, battry, shunt regulator, charger/discharger and power control unit (PCU). In this paper, the development of the DET power system charger/discharger unit and a microprocessor based PCU is developed for simplicity and flexiblity in the modificatin of control algorithm. A 28V bus voltage, 400W power rting power simulator is built and tested to verify the operation of the simulator at each mode and the stability of mode transition is analyzed.

  • PDF

Development of the Monitoring System for maintaining On-site Wastewater Treatment Plants (소규모 현장 오수처리시설의 유지관리를 위한 Monitoring System 개발)

  • Cho, Young-Hyun;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.417-420
    • /
    • 2001
  • The monitoring system for maintaining on-site wastewater treatment plants(Biofilter) was developed. Proposed system applied PLC(Programmable Logic Controller) technique. In process of development, the research against the monitoring parameters which will be able to represent condition and operation of the plants was accomplished. These parameters are ORP(Oxidation-Reduction Potential), Water Level, Pump and Power on/off. Also, to measure, collect, transfer and display these parameters, DMU(Data Measurement Unit), MCU(Main Controller Unit) and Display Board were produced.

  • PDF

Technique for Estimating $CO_2$ and $H_2O$ Exchange between the Atmosphere and the Biosphere : Eddy Covariance Method (광합성과 증발산의 미기상학적 측정기술)

  • Wonsik Kim
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2003.09a
    • /
    • pp.115-128
    • /
    • 2003
  • o What is the flux \ulcorner Flux is the transfer of a quantity per unit area per unit time. The quantities are mass, heat, moisture, momentum and pollutant in micrometeorology. Kinematic flux (Fluid). The reduction in wind speed due to frictional drag transfers momentum from the atmosphere to the surface, creating turbulence that mixes the air and transports heat and water from the surface into the lower atmosphere. (omitted)

  • PDF

Performance Analysis of Frame relay and ATM Interworking Unit (프레임 릴레이와 ATM 연동장치의 성능 분석)

  • 황유선
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10c
    • /
    • pp.508-510
    • /
    • 2000
  • 본 논문에서는 프레임 릴레이(Frame Relay : FR) 망과 ATM(Asynchronous Transfer Mode) 망이 연동할 때, 분석 대상인 연동장치(InterWorking Unit : IWU) 수신부에서 프레임이 처리되는데 걸리는 지연시간을 분석하였다. ATM과 FR 사이의 데이터 처리속도의 차이로 인하여 연동장치의 버퍼에서 프레임이 기다리게 된다. 이 때 지연시간을 IWU에서 ATM 망에서 들어오는 프레임의 평균값을 구한 다음에 Little's formula를 이용하여 수학적으로 분석하였다. 결과적으로 FR 연결된 수가 증가할수록 연동장치에서 프레임의 지연시간은 지수적으로 증가함을 알 수 있었다. 또한 지연시간을 분석하므로 해서 연동장치에서 timeout의 시간을 결정하여 프레임을 재전송할 수 있는 시간을 결정할 수 있었다.

  • PDF

Transient Heat Transfer Analysis of Brake Drum Shape (브레이크 드럼의 형상에 따른 과도 열전달 해석)

  • Kim, Yang-Sul;An, Su-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.65-71
    • /
    • 2008
  • This paper presents a transient heat transfer analysis of a drum brake shape. The transient heat transfer analysis of automotive drum brakes with frictional contact is performed by using the finite element method. The drum brake type studied in the page is the internally expanding one in which two shoes fitted externally with frictional material are forced outward against surface a rotating drum on the wheel unit. In this case, the braking power is produced by the friction force between a drum and a lining, and is converted into heat. The brake drum has constant material properties. The air inside the drum has temperature-dependent thermal conductivity and enthalpy. Radiation effects are ignored. The result explains the reason why hair crack and cause of drum failure occur. The temperature of drum is in proportion to the drum thickness and nonlinear changes at every points of drum. It's necessary for the decrease of the drum temperature to make the air inside drum flow.

Heat Transfer Study to Replace a Tube Bundle of Moisture Separator Reheater at Nuclear Power Plant (원전 습분분리재열기 튜브 번들 교체를 위한 열전달 고찰)

  • Choi, You-Sung;Choi, Kwang-Hee;Lee, Sang-Guk
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.65-71
    • /
    • 2010
  • The plugging rate of reheater tubes of Wolsung unit 1 nuclear power plant has been increased by corrosion and erosion since 1990. As the dimensions of the new first stage reheater bundle tubes which were supplied by Hanjung company to replace were different from old one, numerical calculations are carried out for flow and heat transfer in the reheater bundle tubes of the N.P.P. Numerical calculations consists of thermal performance, drain line pressure drop, flow change by pressure drop of line, stress analysis of finned tubes and analysis of flow induced vibration. Computational analysis using heat transfer research institute program is adopted to verify the results of the numerical calculations. It contains the evalution of performance in the system with view to location of the new reheater bundle and it shows the differences between the numerical calculation results and heat transfer research institute program output.

  • PDF