• 제목/요약/키워드: Transfer unit

검색결과 847건 처리시간 0.034초

Chain Transfer to Monomer and Polymer in the Radical Polymerization of Vinyl Neo-decanoate

  • Balic, Robert;Fellows, Christopher M.;Van Herk, Alex M.
    • Macromolecular Research
    • /
    • 제12권4호
    • /
    • pp.325-335
    • /
    • 2004
  • Molecular weight distributions of poly(vinyl neo-decanoate) produced by the bulk polymerization of the monomer to low conversions were investigated to obtain values of the rate constants for the chain transfer to monomer ( $C_{M}$). The value of $C_{M}$ of 7.5($\pm$0.6)${\times}$10$^{-4}$ was obtained from a logarithmic plot of the number distribution at 5,25, and 5$0^{\circ}C$, which suggests that the activation energy for chain transfer is on the order of 20-25 kJ ㏖$^{-1}$ . These plots were linear between the number and weight-average degrees of polymerization, but not over the whole molecular weight range for which a significant signal was observed in the gel permeation chromatography (GPC) trace. Modeling suggests that the deviations observed at high molecular weights can be explained by branching of the chains through chain transfer to the polymer, with a branching density as low as 10$^{-5}$ , without affecting the slope at low values of the number of monomer unit, N. This deviation from the expected distribution of linear chains was used to estimate the branching densities at low conversion.ion.

연결세경관을 이용한 열교환기의 개발 (A Development of Heat Exchanger by using Small Bore Two-Port Tube)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제27권2호
    • /
    • pp.63-68
    • /
    • 2015
  • The fin and tube type heat exchangers widely used in air conditioners have been developed to improve on the heat transfer performance and compactness. This study presents the new type of tube for the heat exchanger to improve the heat transfer performance by increasing the heat transfer area per unit volume in the air-conditioner heat exchanger. The new type tube can be used for mechanical expansion facility, due to the two-port copper tube. Numerical calculation shows that the heat exchanger using the two-port copper tube outperforms the conventional heat-exchanger using a circular copper tube, in terms of the increased heat transfer coefficient and higher pressure drop. The calculation results were experimentally validated and are in agreement with the experimental results. Compared to the heat exchanger using a conventional circular tube, the heat exchanger with a two-port tube increased the heat transfer coefficient up to 21%, and the pressure dropped up to 16%.

공기조화기내 메쉬삽입 물-공기 직접접촉의 열전달 특성 연구 (Air handling unit utilizing water/air direct contact heat exchanger with mesh)

  • 전용한;문명훈;김종윤;김남진;서태범;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1161-1166
    • /
    • 2008
  • The objective of this research was to investigate the enhancement of heat transfer by mesh in water/air direct contact air conditioning system. Mesh is inserted as a turbulent promoter in front of the water injection nozzle. The heat transfer characteristics with and without mesh and the effect of the number of inserted mesh and mesh porosity size have been studied experimentally. Inserted mesh improves heat transfer efficiency compared to non-inserted mesh system and heat transfer efficiency increased as the number of mesh is increased. Meanwhile, heat transfer efficiency decreased as the porosity of the mesh is increased. With inserted mesh, inlet and outlet temperature difference of air increased more than 50%. Heat exchange time of water/air to reach the 100% humidity decreased less than 30%. This result shows inserted mesh can enhance the performance of the water/air direct contact air conditioning system.

  • PDF

Study on the Equilibrium Point of Heat and Mass Transfer between Liquid Desiccant and Humid Air with in the Solar Air Conditioning System

  • Sukmaji, I.C.;Rahmanto, H.;Agung, B.;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.161-167
    • /
    • 2009
  • The liquid solar air conditioning system is introduced as an alternative solution to control air condition and to save electrical energy consumption. The heat and mass transfer performances of dehumidifier/regenerator in liquid solar air conditioning system are influenced by air and desiccant condition. The application of this system, the thermal energy from the sun and inlet air are unable to control, but operation parameter of other components such as pump, fan and sensible cooling unit are able to control. The equilibrium point of heat and mass transfer are the liquid desiccant and inlet air conditions, where, the heat and mass are not transferred between the liquid desiccant and vapor air. By knowing equilibrium point of heat and mass transfer, the suitable optimal desiccant conditions for certain air condition are funded. This present experiment study is investigated the equilibrium point heat and mass transfer in various air and desiccant temperature. The benefit of equilibrium point heat and mass transfer will be helpful in choose and design proper component to optimize electrical energy consumption.

  • PDF

공기조화기내 메쉬삽입 물-공기 직접접촉의 열전달 특성 연구 (Air Handling Unit Utilizing Water/Air Direct Contact Heat Exchanger with Mesh)

  • 전용한;김종윤;김남진;서태범;김종보
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.75-80
    • /
    • 2008
  • The objective of this research was to investigate the enhancement of heat transfer by mesh in water/air direct contact air conditioning system. Mesh is inserted as a turbulent promoter in front of the water injection nozzle. The heat transfer characteristics with and without mesh and the effect of the number of inserted mesh and mesh porosity size have been studied experimentally. Inserted mesh improves heat transfer efficiency compared to non~inserted mesh system and heat transfer efficiency increased as the number of mesh is increased. Meanwhile, heat transfer efficiency decreased as the porosity of the mesh is increased. With inserted mesh, inlet and outlet temperature difference of air increased more than 50%. Heat exchange time of water/air to reach the 100% humidity decreased less than 30%. This result shows inserted mesh can enhance the performance of the water/air direct contact air conditioning system.

접속 행렬을 이용한 순차 시스템 제어기 설계 (Design of Sequential System Controller Using Incidence Matrix)

  • 전호익;류창근;우광준
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.85-92
    • /
    • 1998
  • 본 논문에서는 페트리 네트로 記述된 제어 사양을 접속 행렬로 해석한 후, 그 결과를 근거로 병렬 시퀸스의 수행이 가능한 순차 시스템 제어기(Sequential System Controller)를 설계하였다. 순차 시스템 제어기는 입력 처리부, 그리고 점화 처리부와 토큰 제어기로 구성된 페트리 네트 제어기로 구성된다. 입력 처리부에서는 입력 신호를 선택하여 점화 처리부로 전달하며, 점화 처리부는 토큰 운전기의 토큰 상태에 따라서 입력된 신호의 점화 여부를 판단하게 된다. 제안된 제어기는 제어 사양의 변경시 접속 행렬을 저장한 롬의 내용 변경만으로 제어기의 변경이 가능하고, 페트리 네트 제어기의 모듈화가 가능하여 기능의 확장이 용이하므로 자동창고 시스템, 반송 시스템, 및 승강기 시스템과 같은 순차 시스템 제어기의 개발 및 실현을 용이하게 할 수 있다.

  • PDF

장기간 소자 모니터링이 용이한 소형 무선랜 무선송신 계측장치 개발 (Development of Portable Measurement Unit with Wireless Transmission by Wireless LAN for Long-term Monitoring)

  • 박소정;박일후;문영선;이국진;김규태
    • 반도체디스플레이기술학회지
    • /
    • 제17권1호
    • /
    • pp.45-49
    • /
    • 2018
  • Portable microcontroller based measurement unit is demonstrated using digital-to-analog convertor module, analog-to-digital convertor module and additional preamplifier circuit with low-budget but excellent performances. Using the designed measurement unit, the measurement of current below 1 nA with applying voltage up to 5 V is successfully carried out. With the WiFi module in microcontroller, measured data is transferred to the user's computer. To evaluate the performance of the measurement unit, the transfer curve of a commercial N-type field effect transistor was measured with the measurement unit and the results is well consistent with that measured using commercial characterization system.

심층수 이용 열교환기 개발을 위한 기초연구: 열교환기 재질이 열교환기 성능에 미치는 영향 (A Fundamentals Study on Heat Exchanger using Deep Ocean Water: Effects of Material on Heat Transfer Performance)

  • 권정태;이창경;허철;조맹익;김기영;권영철
    • 한국산학기술학회논문지
    • /
    • 제14권10호
    • /
    • pp.4658-4664
    • /
    • 2013
  • 본 논문은 심층수 이용 열교환기 개발을 위해 열교환기의 구성 재질로서 티타늄, 알루미늄, 스테인리스, 철, 구리와 알루미늄의 전착코팅 관 등을 이용한 이중관 열교환 실험 장치를 구성하여 열교환 성능을 실험하였다. 기존 심층수 이용 열교환기는 대부분 티타늄 금속으로 이루어져 있다. 티타늄의 재질은 해양 심층수에 적합하나 고가의 금속이다. 티타늄 금속을 대체할 금속으로 알루미늄, 스테인리스, 철, 구리와 알루미늄 전착코팅 관 등을 고려하여 시험하였다. 또한 EES 프로그램을 사용하여 각 관들의 열전달률을 해석하고 이중관 열교환 실험결과와 비교 분석하였다. 열교환시의 성능에 대한 해석값과 실험값을 비교해 보았을 때 10% 내외의 오차범위 내에서 잘 일치하였다. 또한 티타늄 대비 구리관이 가장 좋은 결과치를 보였고 알루미늄 전착코팅 관은 다소 낮은 열전달 수치를 보여 주었으나, 전착처리된 코팅관의 내부식성이 우수한 것을 고려한다면 티타늄 대체가능성이 충분하다고 사료된다.

지역 특성을 고려한 차량 배출물질의 사회적 비용 추정 모형 (A Model for Estimating Social Cost of Mobile Emission Considering Geographical and Social Characteristics)

  • 이규진;최기주
    • 대한교통학회지
    • /
    • 제30권5호
    • /
    • pp.33-42
    • /
    • 2012
  • 본 연구에서는 분석대상 지역의 특성을 고려한 차량 배출물질의 사회적 비용 원단위 추정 모형을 구축하였고, 이를 바탕으로 분석 대상지역의 대기질 가치를 평가하기 위한 방법론을 제시하였다. 구축 모형은 편익이전(Benefit Transfer)기법을 활용한 것으로, 각 지역의 인구밀도와 녹지율이 설명변수로 반영되었다. 본 모형을 적용한 결과, 인구가 밀집되어 있는 서울 지역과 부산 지역에 대한 차량 배출물질의 사회적 비용 원단위는 전국 평균치보다 각각 18.68배, 10.71배 높은 것으로 나타났다. 본 연구는 최근의 녹색교통 정책에 대한 타당성을 판단함에 있어서 보다 신뢰도 있는 결과 도출에 기여할 것으로 기대된다.

심층수 이용 열교환기 개발을 위한 기초연구: 열교환기 부식이 열교환기 성능에 미치는 영향 (A Fundamentals study on Heat Exchanger using Deep Ocean Water: Effects of Corrosion on Heat Transfer Performance)

  • 권영철;이석현;허철;조맹익;이창경;권정태
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5377-5384
    • /
    • 2013
  • 본 논문은 심층수용 열교환기 재질로 티타늄, 알루미늄, 스테인리스, 구리와 알루미늄을 코팅하여 재질의 특성 및 부식이 미치는 영향을 조사하기 위하여 이중관 열교환 실험장치를 활용하였다. 열교환기 재질은 티타늄, 스테인레스, 구리, 알루미늄, 카본 코팅된 알루미늄 등 6종이 비부식관과 부식관에 대하여 해석과 실험이 수행되었다. 해석은 EES 프로그램을 사용하였다. 부식의 영향을 살펴보기 위하여 부식 제조장치를 제작하고, 3.5%의 염수를 $70^{\circ}C$의 온도로 약 6주간 담가서 가속부식을 실시하였다. 부식된 관으로 이중관 열교환기의 성능실험을 실시하여 비부식관과 비교하였다. 실험결과로부터 티타늄을 대체용으로 알루미늄 코팅관(카본 블랙 $150{\mu}m$)의 가능성을 확인하였다.