• 제목/요약/키워드: Transfer rate

검색결과 4,698건 처리시간 0.03초

Concentric Double Pipe 열교환기에서 냉각수 급랭 현상의 모사에 대한 연구 (Study on Simulation of Cooling Water through Concentric Double Pipe Heat Exchanger )

  • 최안철;이성우;신익호;최성웅
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.741-747
    • /
    • 2023
  • In this study, the heat transfer characteristics were numerically analyzed to investigate the possibility of utilizing cooling water using liquid nitrogen. From the study, as the mass flow rate of the hot fluid increased, the heat transfer rate increased by 8.9-81.7%. And lowering the inlet temperature of the hot fluid resulted in increase in the heat transfer rate by 33.8-71.5%. As for the filling level of liquid nitrogen, as higher filling level led to a decrease in the outlet temperature and an increase in the overall heat transfer coefficient.

전단율에 의존적인 비뉴턴 유체의 열전도율이 열전달 향상에 미치는 영향 (The effect of the shear-rate dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement)

  • 신세현;이성혁;손창현
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1717-1724
    • /
    • 1996
  • The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. An axially-constant heat flux boundary condition was adopted in the thermal fully developed region. The present analytical results of Nusselt numbers for various non-Newtonian fluids show heat transfer enhancement over those of a shear rate-independent thermal conductivity fluids. The present analytical results showed good agreement with the previous experiments which excluded the temperature-dependent viscosity effect on heat transfer. This study also proposes the use of a shear rate-dependent thermal conductivity fluids in the design of a heat exchanger for heat transfer enhancement as well as reduction of fouling.

RTS-SAREK을 이용한 사무용 건물의 나이트 퍼지 성능 평가 (Night Purge Evaluation Using the RTS-SAREK in Office Buildings)

  • 신동신;박성근;박영수;박지수;이진영
    • 설비공학논문집
    • /
    • 제27권12호
    • /
    • pp.633-638
    • /
    • 2015
  • This study evaluates the capacity of night purging in office buildings to reduce the cooling load. RTS-SAREK is used to estimate the performance of night purging on the steady state. To overcome steady state RTS program limitations, we added unsteady heat transfer equations. When the ACH (Air Change per Hour) increases, the wall temperature decreases in both the steady and unsteady states. The unsteady heat transfer rate is different from the steady transfer rate, which validates the unsteady calculation. When ACH is low, the heat transfer rate increases continuously with time. When ACH becomes higher, the heat transfer rate increases and decreases with time. When ACH is quite high, there exists a large difference in the heat transfer rate between the steady and unsteady calculations, which emphasizes the importance of the unsteady calculation.

흡수식 냉온수기용 증발기의 전열성능에 관한 연구 (A study on the heat transfer performance of evaporator for absorption chiller)

  • 권오경;차동안;윤재호;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.192-197
    • /
    • 2008
  • The objectives of this paper are to measure the heat transfer and pressure drop of the heat transfer tube for an evaporator of absorption system applications. Five types of heat transfer tubes with different shape and heat transfer area are tested in the present experiment. Heat transfer and pressure drop performance of heat transfer tubes are measured in various operating conditions, and compared each other. The results show that the heat transfer rate of thermoexcel notch tube and low fin tube increases about 27.6% and 11.6% at the refrigerant flow rate 250 kg/h compared with that of bare tube, respectively. The thermoexcel notch tube is shown the best performance considering pressure drop and heat transfer coefficient.

  • PDF

열전달 계수 최대화를 위한 마이크로 증발기의 최적 설계 (Optimal design of a micro evaporator to maximize heat transfer coefficient)

  • 성태종;오대식;서태원;김종원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2097-2101
    • /
    • 2007
  • This paper presents an optimal design of a micro evaporator which maximizes the heat transfer coefficient. Number of gaps, spanwise distance and streamwise distance are selected as the geometric design parameters. Mass flow rate of the refrigerant is selected as the non-geometric design parameter. Temperature at the surface of the heater is measured to valuate the heat transfer coefficient. Nine experiments are conducted using $L_9(3^4)$ orthogonal array. Maximum heat transfer coefficient is 640 W/$m^2K$ at the parameters of 2 gaps, 0.2 mm spanwise distance, 1.0 mm streamwise distance and 0.72 g/s mass flow rate. Among the 3 geometric parameters, the spanwise distance is the most sensitive parameter influencing the heat transfer coefficient. We conduct a second stage of experiment to increase the heat transfer coefficient by reselecting the mass flow rate. We concluded that 0.87 g/s is the optimized flow rate for an active micro cooler resulting in a heat transfer coefficient of 651 W/$m^2K$.

  • PDF

소에 있어서 영양아세포구의 공동 이식이 수정란이식 수태율에 미치는 영향 (Effect of Trophoblastic Vesicles Co-Transfer on Pregnancy Rate Following Embryo Transfer in Cattle)

  • 양보석;오성종;임기순;박성재;양병철;김경남
    • 한국수정란이식학회지
    • /
    • 제16권1호
    • /
    • pp.29-34
    • /
    • 2001
  • To investigate the effect of co-transfer of trophoblastic vesicle (TV) with frozen-thawed in vitro Produced (IVP) bovine embryo on pregnancy rate, IVP blastocysts were transferred to synchronized recipients. Elongated blastocysts were recovered at Day 13 to 15, and dissected more than 4 pieces to removed the embryonic disc. Throphoblastic fragments were cultured for 48 hours to make throphoblastic vesicles (TVs). TVs were cryopreserved in ethylene glycol or vitrification solution and frozen-thawed TVs were co-transferred to recipients with frozen-thawed IVP embryos. 1 The recovery rate of elongated blastocyst on Day 13 to 15 was 22.5% (18/80) and the size of recovered elongated blastocysts was 0.2∼5.0mm. 2. Eighteen elongated blastocysts were dissected into 88 pieces and 61.4% of those pieces were formed to TV (54/88) 3. The viability of frozen-thawed TV in ethylene glycol was higher than in vitrified solution (92.8% vs. 68.8%) 4. The pregnancy rate in co-transfer with frozen-thawed TV and IVP blastocyst was better than transfer only IVP blastocysts (50.0% vs. 23.1%).

  • PDF

한우 수정란의 동결보존 및 쌍자생산에 관한 연구 II. 이분 수정란의 이식과 쌍자 생산 (Studies on Embryo Cryopreservation and Twinning by Embryo Transfer of Korean Native Cattle II. Transfer of Bisected Embryos and Production of Twin Calves)

  • 손동수;김일화;이동원;안병석;이광선;신형두;박노웅;최상용
    • 한국수정란이식학회지
    • /
    • 제12권1호
    • /
    • pp.91-102
    • /
    • 1997
  • This study was carried out to enhance the efficiency of Korean Native cattle embryos and establish the techniques for producing the twin calves. Bisected embryos without zona pellucida which were divided by simple method not using holding pipette or whole two embryos were transferred to recipients.The pedigrees of monozygotic twin calves produced by transfer of bisected pair embryos were identified. The results obtained were as follows ; The average successful bisection rate was 89.16%. The embryos of blastocyst stage (91.66%) were bisected successfully at significantly (P<0.05) higher rate, compared with the morula stage embryos (86.66%). The average survival rate of bisected embryos following 24 hours culture was 59.02%. The survival rate of morula stage embryos (62.50%) was significantly (P<0.05) higher than that of blastocyst stage embryos (55.5%). For the production of monozygotic twin calves, ten pairs of flesh or frozen demi-em- lymphocytes antigen, the twin calves produced by transfer of bisected pair embryos of Korean Native cattle were identified in pedigrees and confirmed as monozygotes.

  • PDF

한우 체외수정란 Biopsy 후 PCR 기법을 이용한 성 판정과 성감별 수정란의 이식 (Sex Determination of Biopsied Hanwoo Embryos by Polymerase Chain Reaction and Embryo Transfer with Sexed Blastocysts)

  • 김용준;정구남;이해이;조성우;김용수;유일정
    • 한국수정란이식학회지
    • /
    • 제15권3호
    • /
    • pp.219-230
    • /
    • 2000
  • This study was carried out to determine the factors on achieving good viability of embryos biopsied fur sexing, to investigate pregnancy rate following embryo transfer(ET) with sexed embryos, and to confirm the accuracy for the calves bort following ET with sexed embryos by polymerase chain reaction(PCR). To investigate viability of Hanwoo embryos after biopsy for sexing, fresh and frozen/thawed embryos were biopsied according to different developmental day of blastocysts, different stage of blastocysts, and different biopsy grade and the embryos themselves were incubated for 2 hours in TCM199 after microsection to be evaluated morphologically for recovery as blastocyst. The results obtained were as follows : 1. The rate of oocytes cleaved in vitro and the rate of blastocyst of the cleaved oocytes were 52.5% and 21.6%, respectively. The rate of blastocyst on day 8 was 11.2%, denoting the highest rate during whole culture period posterior to in vitro fertilization(IVF) 2. After biopsy for sexing, the viability rate of blastocyst on day 7, 8 and 9 was 75.0%, 88.4%, and 100.0%, respectively and the viability of early, mid, and expanded blastocyst after biopsy was 75.0%, 88.9%, and 91.1%, respectively The viability rate of fresh and frozen/thawed embryos was 89.9%, 71.4%, respectively. And the viability of expanded, hatching, and hatched blastocyst of frozen/thawed embryos was : 75.0%, 75.0%, and 50.0%, respectively. The viability of embryos according to biopsy grade of 10∼20%, 21∼30%, and 31∼40% was 85.7%, 91.5%, and 71.4%, respectively. 3. Pregnancy rate after transfer with biopsied embryo between flesh and frozen/thawed embryos was 22.6% and 20.0%, respectively. 4. In comparison between sex by PCR method and sex of calves born after embryo transfer, the accuracy of sex deterimination was 92.3% (12/13).

  • PDF

확대 모델을 이용한 루버 휜의 국부 열전달 특성변화에 관한 연구 (Study of the local heat transfer characteristic on the louver fin by using the expansion model)

  • 김정국;소산 번;상원 헌;박병덕;김동휘;사용철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.227-232
    • /
    • 2008
  • The present study was investigated the local heat transfer characteristics and temperature distribution on the louver fin by using the expansion model. Heat transfer rate, frost mass and temperature distribution of the louver fin under frosting condition were experimentally investigated. Local heat transfer rate and heat flux on the louver were analyzed by the conduction heat transfer between top and lower part of the louver. The experimental key parameter was brine inlet temperature(-5, -10, $-15^{\circ}C$). The heat transfer performance and frost mass at brine temperature of $-15^{\circ}C$ were increased by maximum 3 time than the brine temperature of $-5^{\circ}C$. At all experimental case, local heat transfer rate and heat flux of the louver were almost symmetry at the louver number of 6. Especially, local heat transfer rate and heat flux were maximum increased on the louver number of 4 and 8.

  • PDF

복사전달방정식을 이용한 조사율 추정 (Estimation of dose rate using radiative transfer equations)

  • 문윤섭;김유근;이영미
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1195-1204
    • /
    • 2002
  • We calculated dose rate using radiative transfer equations to consider radiative processes distinctly. The dose rate at Pohang(36°02'N, 129°23'E) was calculated using measured ozone and meteorological data and two-stream approximations(quadrature, Eddington, delta Eddington, PIFM(practical improved flux method), discrete ordinate, delta discrete ordinate) are used in solving equation. The purpose of this study is to determine the most compatible radiative transfer approximation for simulating the radiative and photochemical processes of atmosphere through comparision between calculated and measured values. Dose rate of the biologically effective irradiance in the region 0.28-0.32 U m showed the highest value when quadrature and Eddington was used and lower value on condition that delta scaling was applied. Correlation coefficient between dose rate at surface using radiation transfer equation and measured UV-B at Pohang was 0.78, 0.79 and 0.81 when delta Eddington, PIFM and delta discrete ordinate were used. Also, in case of above approximations were used, MBE(Mean Bias Error) was within -0.3MED/30min and RMBE(Relative Mean Bias Error) was below 10% between 1200 LST and 1400 LST Approximations which are compatible in estimating radiative process are delta Eddington, PIFM and delta discrete ordinate. Especially, in case that radiative process is considered more detail, delta discrete ordinate increased the number of stream is proper.