• 제목/요약/키워드: Transfer rate

검색결과 4,708건 처리시간 0.035초

체외 배양액의 조성과 혈청의 첨가가 한우 체외 수정란의 발달과 임신율에 미치는 효과 (Development a Following of Serum Addition In Vitro Culture and Embryo Transfer)

  • 최수호;박용수;이준희;강태영;김주헌;노규진
    • 한국수정란이식학회지
    • /
    • 제23권1호
    • /
    • pp.51-57
    • /
    • 2008
  • The present study investigated the efficient methods to produce in vitro Hanwoo embryos, and to improve the pregnancy rate. The developmental rate, total cell number and ICM ratio of in vitro embryos were compared amongst different culture media. Comparisons were also made on the status of recipients, pregnancy rate along with day of transfer after the estrus. Development of embryos into blastocyst stage in IVMD101 supplemented with 5% fetal bovine serum (FBS) group was significantly higher (34.2%) than that of TCM-199 supplemented with 5% FBS (26.8%) and IVMD101 without FBS (25.9%) (p<0.05). The development rate to blastocyst stage was significantly faster in IVMD101(5% FBS) than that of other groups ($0.2{\sim}2.3%$) (p<0.05). The average number of inner cell mass and trophectoderm were similar among treatment groups, which were $36.0{\sim}44.7$ and $83.3{\sim}106.7$. However, total cell number in IVMD101(5% FBS and 0% FBS) was significantly higher than that of TCM199(5% FBS). There were no differences in the pregnancy rate among treatment groups (32.0%, 33.9% and 28.6%, respectively). However, the pregnancy rate of Day 6 embryos cultured in IVMD101(5% FBS) was significantly (p<0.01) higher than IVMD101 without FBS and TCM-199 + 5% FBS (38.0% vs. 17.2% and 32.4%, respectively). No significant difference was observed for the pregnancy rate between heifer and cow transferred with Day 6 embryos cultured in IVMD 101(5% FBS) (42.7% and 39.3%, respectively). However, there was a significant difference of pregnancy rate (p<0.05) in heifer between one and two embryos transferred (31.4% and 41.9%). There was no difference of pregnancy rate among transfer days after estrus between heifer and cow, but the pregnancy rate of transfer to heifer with day 6 after estrus was significantly higher (p<0.05) than that of day 7 and 8 (22.2% vs. 49.0% and 38.7% respectively). Based on the above findings, there is a possibility to produce in vitro produced embryos cultured in IVMD101(5% FBS) showed higher blastocyst rate and the increased cell number. In terms of the pregnancy rate of in vitro produced embryos, the highest pregnancy rate was observed when two embryos were cultured in IVMD101(5% FBS) and transferred.

연속조작 기포탑에서 열전달 모델 및 에너지 소멸 속도 (Heat Transfer Model and Energy Dissipation Rate in Bubble Columns with Continuous Operation)

  • 장지화;서명재;임대호;강용;정헌;이호태
    • Korean Chemical Engineering Research
    • /
    • 제47권5호
    • /
    • pp.587-592
    • /
    • 2009
  • 연속조작 기포탑에서 열전달 메카니즘을 검토하기 위하여 열전달 모델과 에너지 소멸속도를 고찰하였다. 기포탑에서 표면갱신이론(Surface renewal theory)에 기초한 비정상상태 열전달모델에 의한 에너지소멸 속도($E_D$)는 기포탑에서 기체와 액체상의 거동에 의한 수력학적인 에너지소멸 속도($P_v$)와 비교하여 매우 작게 나타났다. 이와같은 결과로 표면갱신 이론에 의한 비정상상태 열전달모델에서 사용된 에너지 소멸속도와 기포탑 전체에 대한 수력학적 에너지 수지에 의해 산출된 수력학적 에너지 소멸속도는 산출 메카니즘이 서로 다른 별개의 에너지 소멸속도로 규명되었다. 이들 두 종류의 에너지 소멸속도를 각각 본 연구의 실험 변수인 기체와 액체 유속의 상관식으로 나타내어 완전히 다른 값을 나타냄을 확인하였다.

마이크로웨이브와 열전매체유를 이용한 슬러지 건조방법 (Sludge Drying Method Using Microwave Drying Device and Heat Transfer Medium Oil)

  • 김용렬;손민일
    • 한국응용과학기술학회지
    • /
    • 제28권3호
    • /
    • pp.367-373
    • /
    • 2011
  • This research is a basic researching process for producing solid fuel that mixing paper sludge and Heat Transfer Medium Oil. Under the presence of Heat Transfer Medium Oil, paper sludge is heated and dried with home appliance microwave for comparing drying efficiency and energy efficiency of different types of drying method. As a result, Heat Transfer Medium Oil and paper mixing case of drying method, OMD, is the most efficient way to shorten the time for evaporating moisture in the paper sludge. In addition, heat transfer effect and density is increased with adding Heat Transfer Medium Oil by microwave. Future more, OMD's energy cost for evaporating whole moisture is 78% cheaper than MD. Also, OMD process shows the best energy efficiency with comparing other process. Evaporation rate of paper sludge evaporation process with microwave is 11.66% increased by adding Heat Transfer Medium Oil 150g. Preheating Heat Transfer Medium Oil or improving different ways injecting Heat Transfer Medium Oil is a good way to increase a rate of initiative moisture evaporation process.

Impact of co-transfer of embryos produced by somatic cell nuclear transfer using two types of donor cells on pregnancy outcomes in dogs

  • Son, Young-Bum;Jeong, Yeon Ik;Jeong, Yeon Woo;Hossein, Mohammad Shamim;Hwang, Woo Suk
    • Animal Bioscience
    • /
    • 제35권9호
    • /
    • pp.1360-1366
    • /
    • 2022
  • Objective: The present study analyzed the influence of co-transferring embryos with high and low cloning efficiencies produced via somatic cell nuclear transfer (SCNT) on pregnancy outcomes in dogs. Methods: Cloned dogs were produced by SCNT using donor cells derived from a Tibetan Mastiff (TM) and Toy Poodle (TP). The in vivo developmental capacity of cloned embryos was evaluated. The pregnancy and parturition rates were determined following single transfer of 284 fused oocytes into 21 surrogates and co-transfer of 47 fused oocytes into four surrogates. Results: When cloned embryos produced using a single type of donor cell were transferred into surrogates, the pregnancy and live birth rates were significantly higher following transfer of embryos produced using TP donor cells than following transfer of embryos produced using TM donor cells. Next, pregnancy and live birth rates were compared following single and co-transfer of these cloned embryos. The pregnancy and live birth rates were similar upon co-transfer of embryos and single transfer of embryos produced using TP donor cells but were significantly lower upon single transfer of embryos produced using TM donor cells. Furthermore, the parturition rate for TM dogs and the percentage of these dogs that remained alive until weaning was significantly higher upon co-transfer than upon single transfer of embryos. However, there was no difference between the two embryo transfer methods for TP dogs. The mean birth weight of cloned TM dogs was significantly higher upon single transfer than upon co-transfer of embryos. However, the body weight of TM dogs did not significantly differ between the two embryo transfer methods after day 5. Conclusion: For cloned embryos with a lower developmental competence, the parturition rate and percentage of dogs that remain alive until weaning are increased when they are co-transferred with cloned embryos with a greater developmental competence.

LiBr계 용액을 사용한 수직관 흡수기의 열 및 물질 전달에 관한 연구 (A Study on Heat and Mass Transfer in a Vertical Tube Absorber Using LiBr Family Solutions)

  • 조현철;김종보;정시영;강상우;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.196-206
    • /
    • 1995
  • Experimental investigations on heat and mass transfer characteristics in a vertical tube absorber have been carried out. Three different copper tubes with a length of 1.5m have been tested using LiBr solution and LiBr-$CaCl_2$ solution. The effects of solution flow rate, cooling water temperature, solution inlet temperature and evaporation temperature have been investigated in detail. It is found that heat transfer coefficient increases gradually with the increase of solution flow rate, but decreases rapidly for the flow rates less than 0.02kg/ms. The grooved tube generally shows better heat transfer performances than the smooth tube. LiBr solution shows almost no absorption capability for the cooling water temperatures over $40^{\circ}C$. LiBr-$CaCl_2$ gives less decreasing rate in absorption capability at these temperatures and the heat transfer coefficient becomes less dependent on the types of tubes in use. Considering heat and mass transfer rates, LiBr-$CaCl_2$ solution is found to be more suitable than LiBr solution for air cooled absorber, which operates at higher temperature than water cooled absorber.

  • PDF

수평관 내에서 이산화탄소 초임계 가스냉각 과정의 열전달 및 압력강하 특성에 관한 실험적 연구 (An Experimental Study on Heat Transfer and Pressure Drop Characteristics during Supercritical Process of Carbon Dioxide in a Horizontal Tube)

  • 최이철;강병하;김석현
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.414-420
    • /
    • 2004
  • The heat transfer and pressure drop characteristics associated with the gas cooling of the supercritical carbon dioxide in a horizontal tube have been investigated experimentally. This problem is of particular interest in the design of a gas cooler of cooling systems using $CO_2$refrigerant. The test section is consisted of 6 series of 455 mm in length, 4.15 mm ID copper tube, respectively. The effects of the inlet temperature, pressure and mass flow rate on the heat transfer and pressure drop of $CO_2$in a horizontal tube is studied in detail. The heat transfer coefficient of $CO_2$is varied by temperature, inlet pressure, and mass flow rate of $CO_2$. This has maximum value at near the pseudocritical temperature. The pressure drop is changed by inlet pressure and mass flow rate of $CO_2$. The results have been compared with those of previous work. The heat transfer correlation at the supercritical gas cooling process is also suggested.

유출홀이 설치된 회전하는 정사각 유로에서의 열/물질전달 특성 (Heat/Mass Transfer Characteristics on Rotating Square Channel with Bleed Holes)

  • 김상인;김경민;이동현;이동호;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1104-1109
    • /
    • 2004
  • The present study has been conducted to investigate convective heat/mass transfer inside the cooling passage with bleed holes. The rotating square channel has 40.0 mm hydraulic diameter and the bleed holes on the leading surface of the channel. The hole diameter of bleed hole is 4.5 mm and its spacing (P/d=4.9) is about five times of hole diameter. Mass flow rate through bleed holes is 10% of the main flow rate and rotation number is changed form 0.0 to 0.4. A naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The cooling performance is influenced by mass flow rate through bleed holes and Coriolis force of rotating channel for fixed reynolds number. The heat transfer is enhanced around holes on the leading surface because of trapping flow by bleeding. However heat transfer on the leading surface is decreased due to Coriolis force.

  • PDF

다양한 전열관 내부 홈 변화에 의한 열전달 성능에 관한 연구 (A Study on the Heat Transfer Performance Using Various Grooved Heat Transfer Tubes)

  • 한규일;정원규;예석수;박성현
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.26-32
    • /
    • 2000
  • Single-phase heat transfer performance and pressure drop for internally grooved tubes with angles were studied. Experiments were carried out in a counter flow heat exchanger with water as a working fluid. Two commercially available internally grooved tubes and smooth tube were tested. The internal diameter of the smooth tube was 16.5mm and the internal diameters of grooved tubes were 15.4mm, 14.9mm, 15.0mm, 16.7mm, respectively. Grooved angles in the tubes were $37^{\circ},\;43^{\circ},\;45^{\circ},\;50^{\circ}$, respectively. An experimental device to measure the friction factor and heat transfer coefficient was constructed. The experimental results were obtained for the fully developed turbulent flow of water in tube on the condition of uniform heat flux. As the increase of flow rate, Reynolds number, numbers of groove and grooved angle led to the increase of pressure drop. Also this paper showed that heat transfer rate increased with increasing numbers of groove and grooved angle. An empirical relation taken from this study represented most of the data within ${\pm}25%$.

  • PDF

경사진 원형관에서의 공냉응축에 관한 실험적 연구 (Experimental Study of Air-cooled Condensation in Slightly Inclined Circular Tube)

  • 김동억;권태순;박현식
    • 한국유체기계학회 논문집
    • /
    • 제19권4호
    • /
    • pp.29-34
    • /
    • 2016
  • In this study, the experimental investigation of air-cooled condensation in slightly inclined circular tubes with and without fins has been conducted. In order to assess the effects of the essential parameters, variable air velocities and steam mass flow rates were given to the test section. The heat transfer performance of air-cooled condensation were dominantly affected by the air velocity, however, the increase of the steam mass flow rate gave relatively weaker effects to total heat transfer capability. And in the experimental cases with the finned tube, the total heat transfer rate of the finned tube was significantly larger than that of the flat tube. From those results, it can be confirmed that the most important parameter for air-cooled condensation heat transfer is the convective heat transfer characteristics of air. Therefore, for the well-designed long-term cooling passive safety system, the consideration of the optimal design of the fin geometry is needed, and the experimental and numerical validations of the heat transfer capability of the finned tube would be required.

PF 열교환기의 열전달과 압력강하 특성 실험 연구 (Experimental of Study on Heat Transfer and Pressure drop of PF Heat Exchangers)

  • 엄유식;서동남;박경만;이상재;김대훈;권영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.519-524
    • /
    • 2008
  • In the present study, the air-side heat transfer and pressure drop characteristics of the fin-tube and PF heat exchangers have been experimentally investigated under the cooling standard condition. Fin type of PF heat exchanger is a triangler and squarer form. The experimental data of the slit fin-tube and two kinds of PF heat exchangers are measured using the air-enthalpy calorimeter and the constant temperature water bath. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. The heat transfer rate and pressure drop of PF-2 heat exchanger of the squarer fin is larger than that of PF-1 heat exchanger of the triangler fin. As the inlet air temperature increases, the heat transfer rate decreases and the pressure drop is nearly uniform.

  • PDF