Heat/Mass Transfer Characteristics on Rotating Square Channel with Bleed Holes

유출홀이 설치된 회전하는 정사각 유로에서의 열/물질전달 특성

  • 김상인 (연세대학교 대학원 기계공학과) ;
  • 김경민 (연세대학교 대학원 기계공학과) ;
  • 이동현 (연세대학교 대학원 기계공학과) ;
  • 이동호 (연세대학교 대학원 기계공학과) ;
  • 조형희 (연세대학교 기계공학과)
  • Published : 2004.11.03

Abstract

The present study has been conducted to investigate convective heat/mass transfer inside the cooling passage with bleed holes. The rotating square channel has 40.0 mm hydraulic diameter and the bleed holes on the leading surface of the channel. The hole diameter of bleed hole is 4.5 mm and its spacing (P/d=4.9) is about five times of hole diameter. Mass flow rate through bleed holes is 10% of the main flow rate and rotation number is changed form 0.0 to 0.4. A naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The cooling performance is influenced by mass flow rate through bleed holes and Coriolis force of rotating channel for fixed reynolds number. The heat transfer is enhanced around holes on the leading surface because of trapping flow by bleeding. However heat transfer on the leading surface is decreased due to Coriolis force.

Keywords