• 제목/요약/키워드: Transfer mode

검색결과 1,101건 처리시간 0.027초

GMAW 용적이행 현상에 미치는 Ca의 영향 (Effect of Ca on Droplet Transfer Phenomena in GMA Welding)

  • 안영호;방국수;이종봉;장내웅
    • Journal of Welding and Joining
    • /
    • 제12권4호
    • /
    • pp.76-84
    • /
    • 1994
  • Droplet transfer modes due to welding conditions and the effect of Ca in welding wire on droplet transfer were investigated. Droplet transfer mode in CO$_{2}$ welding was classified into 2 modes, that is, short circuit and globular transfer, with increasing welding current and voltage. With increasing Ca content in wire, repulsive pressure due to vaporization of Ca was considerably increased. In short circuit transfer region, arcing time was increased and droplet transfer cycle was decreased, with increasing Ca content. In globular transfer region, welding condition for globular transfer was lower current region, with increasing Ca content.

  • PDF

내로우 갭 적용을 위한 핫와이어 송급 레이저용접 - 고속촬영을 통한 와이어 용융/이행 현상과 아크 포메이션 분석 - (Hot Wire Laser Welding of Multilayer for Narrow Gap - Analysis of Wire Melting/Transfer and Arc Formation Phenomenon by High Speed Imaging -)

  • 김경학;방한서;방희선
    • Journal of Welding and Joining
    • /
    • 제34권5호
    • /
    • pp.26-32
    • /
    • 2016
  • In this study, Hot-wire laser welding (HWLW) without keyhole which deposits filler material by feeding hot wire into the process zone has been performed to increase process performance. From the analysis of High Speed Imaging (HSI), for higher voltage, the process is prone to arc formation and drop transfer, which is disagreeable transfer mode. It is necessary that arc formation and drop (globular) transfer should be avoided by lower voltage. Therefore, continuous wire melting and transfer mode is preferred when adopting this process. The HWLW technique has high potential in terms of performance, precision, robustness and controllability for thick section of narrow gap.

화염 전달함수 및 DMD 기법을 이용한 모형 가스터빈의 연소불안정성 평가 (Evaluation of Combustion Instability in a Model Gas Turbine Adopting Flame Transfer Function and Dynamic Mode Decomposition)

  • 손진우;손채훈;윤지수;윤영빈
    • 한국연소학회지
    • /
    • 제22권2호
    • /
    • pp.1-8
    • /
    • 2017
  • To evaluate the combustion instability of a gas turbine combustor, the DMD technique was applied. The mode frequency results for each fuel composition were compared with FFT(Fast Fourier Transform) results. The damping coefficient, which is a quantitative parameter for combustion instability, was evaluated for 5 experimental cases. The flame transfer function (FTF) was calculated in the most unstable test case. In deriving the FTF, gain and phase were calculated using DMD technique. As a result of the analysis of the OH radical perturbation of the DMD, the heat release fluctuation was the highest at 100 Hz, at which the highest value of gain is observed. The frequency of FFT and FTF were different. In order to clarify the reason for this, FTF for various resonance frequencies was performed and it shows that the pattern of gain was similar to FFT.

Time-Domain Analysis of Wireless Power Transfer System Behavior Based on Coupled-Mode Theory

  • Shim, Hyunjin;Nam, Sangwook;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • 제16권4호
    • /
    • pp.219-224
    • /
    • 2016
  • In this paper, coupled-mode theory (CMT) is used to obtain a transient solution analytically for a wireless power transfer system (WPTS) when unit energy is applied to one of two resonators. The solutions are compared with those obtained using equivalent circuit-based analysis. The time-domain CMT is accurate only when resonant coils are weakly coupled and have large quality factors, and the reason for this inaccuracy is outlined. Even though the time-domain CMT solution does not describe the WPTS behavior precisely, it is accurate enough to allow for an understanding of the mechanism of energy exchange between two resonators qualitatively. Based on the time-domain CMT solution, the critical coupling coefficient is derived and a criterion is suggested for distinguishing inductive coupling and magnetic resonance coupling of the WPTS.

6차 단일종단 이중모드 타원응답 필터의 회로망 파라미터 추출에 관한 연구 (Network Parameters of 6-Pole Dual-Mode Singly Terminated Elliptic Function Filter)

  • Lee, Juseop;Uhm, Man-Seok;Yom, In-Bok;Lee, Seong-Pal
    • 한국통신학회논문지
    • /
    • 제28권7A호
    • /
    • pp.557-562
    • /
    • 2003
  • An output multiplexer of manifold type is widely used in a recent satellite transponder for its mass and volume reduction. For correct operation, the filters of such a multiplexer must be singly terminated. In this paper, a simple synthesis method of a 6-pole dual-mode singly-terminated filter is described. From the transfer function of the filter, network parameters such as in/output terminations and coupling coefficients are obtained easily without complicated matrix algebra such as orthogonal projection and similarity transformation. Two different-structure filters are taken into consideration and the network parameters of each filter have been extracted from the same transfer function. It is shown that the responses of two filters are same to each other since their network parameters are obtained from the same transfer function. The method described in this paper can be applied to the other degree singly terminated filter.

질량감도 해석에 의한 2차원 연속계의 진동특성에 관한 연구 (A Study on The Identification of Characteristics For The 2 Dimensional Continuous Vibration System By Mass Sensitivity Analysis)

  • 이정윤;박호;오재응
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.339-348
    • /
    • 1990
  • Techniques which are able to predict and control dynamic characteristics, not affecting the vibrational characteristics on the modification of structural design, are being studied. As one of these techniques, experimental modal analysis is widely applied by many researchers. In this study, modal analysis is performed using transfer matrix method by a macro computer. The developed program would estimate the structural modal parameters precisely, and the validity of this program is certified by comparing with the experimental results of .GAMMA A. structure. Estimated modal parameters(natural frequency, vibrational mode, equivalent mass, etc.) are in accord with the experimental results. Also, the optimal location of the additive mass is determined by the evaluation of the vibrational mode and the equivalent mass. The relation between the additive mass and the equivalent mass is specified, and we come to know that the ratio of equivalent mass to additive mass alter linearly within the range of 20%.

전산유동해석을 이용한 100 $MW_e$급 석탄 순산소 연소 실증 보일러의 설계 및 운전조건 평가 (Numerical Simulation of a 100 $MW_e$-scale Wall-fired Boiler for Demonstration of Oxy-coal Combustion)

  • 채태영;박상현;홍재현;양원;이상훈;류창국
    • 한국연소학회지
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 2011
  • As one of the main technologies for carbon capture and storage in power generation, oxy-coal combustion is being developed for field demonstration in Korea. This study presents the results of numerical simulation for combustion in a single-wall-fired 100 $MW_e$-scale boiler proposed for the initial design of the demonstration plant. Using a commercial CFD code, the detailed combustion, flow and heat transfer characteristics were assessed both for air-mode and oxy-mode combustion. The results show that stable combustion can be achieved in the dual mode operation with the current boiler configuration. However, the differences in the flow pattern and heat transfer between the two combustion modes need to be considered in the design and operation which is mainly due to the larger density and specific heat of $CO_2$ compared to $N_2$. Further development of the boiler design is required using improved numerical modeling for radiative heat transfer and combustion.

질량변경에 따른 연속계의 동특성변화 예측 (Prediction of Dynamic Characteristics of Continuous Systems Due to the Mass Modification)

  • 이정윤;최상렬;박천권;오재응;정석주
    • 대한기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.248-256
    • /
    • 1993
  • 본 연구에서는 연속계의 진동모드를 구하여 일반질량(generalize mass)을 유 동하였으며 집중, 분포질량 변경에 따른 일반질량 변화량을 산출하여 감도계수를 구하 는 새로운 연속계 감도해석 방법을 제안하였고, 타당성을 검증하기 위해 외팔보, 계단 보에 적용하여 감도계수, 고유진동수, 진동모드, 전달함수의 변화량을 예측하고 이론 치와 비교하였다. Fig.1은 본 연구의 흐름도를 나타낸다.

Design and Implementation of an Active EMI Filter for Common-Mode Noise Reduction

  • Lee, Kuk-Hee;Kang, Byeong-Geuk;Choi, Yongoh;Chung, Se-Kyo;Won, Jae-Sun;Kim, Hee-Seung
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1236-1243
    • /
    • 2016
  • This paper presents the analysis and design of an active electromagnetic interference (EMI) filter (AEF) for the common-mode (CM) noise reduction of switching power converters. The features of the several types of AEFs are discussed and compared in terms of implementation. The feed-forward AEF with a voltage-sensing and voltage-cancellation (VSVC) structure is implemented for an LLC resonant converter to replace a multiple-stage passive EMI filter and thereby reduce CM noise. The characteristics and performance of the VSVC-type AEF are investigated through theoretical and experimental works.

PCS의 전류제어모드와 전압제어모드의 전환기법 (Current and Voltage Control Mode Transfer Method for PCS)

  • 정재헌;박해영;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.265-266
    • /
    • 2010
  • This paper describes a new method for the seamless operation mode transfer of a PCS. The proposed method provides reduced STS turn off time and smooth mode change between current and voltage control of the PCS in case of line fault. The usefulness of the method is verified through simulations.

  • PDF