• Title/Summary/Keyword: Transfer Pattern Analysis

Search Result 255, Processing Time 0.022 seconds

Transient heat transfer analysis of functionally graded CNT reinforced cylinders with various boundary conditions

  • Moradi-Dastjerdi, Rasool;Payganeh, Gholamhassan
    • Steel and Composite Structures
    • /
    • v.24 no.3
    • /
    • pp.359-367
    • /
    • 2017
  • In this work, transient heat transfer analysis of functionally graded (FG) carbon nanotube reinforced nanocomposite (CNTRC) cylinders with various essential and natural boundary conditions is investigated by a mesh-free method. The cylinders are subjected to thermal flux, convection environments and constant temperature faces. The material properties of the nanocomposite are estimated by an extended micro mechanical model in volume fraction form. The distribution of carbon nanotube (CNT) has a linear variation along the radial direction of axisymmetric cylinder. In the mesh-free analysis, moving least squares shape functions are used for approximation of temperature field in the weak form of heat transform equation and the transformation method is used for the imposition of essential boundary conditions. Newmark method is applied for solution time depended problem. The effects of CNT distribution pattern and volume fraction, cylinder thickness and boundary conditions are investigated on the transient temperature field of the nanocomposite cylinders.

Nonlinear approach to modeling heteroscedasticity in transfer function analysis (시계열 전이함수분석 이분산성의 비선형 모형화)

  • 황선영;김순영;이성덕
    • The Korean Journal of Applied Statistics
    • /
    • v.15 no.2
    • /
    • pp.311-321
    • /
    • 2002
  • Transfer function model(TFM) capturings conditional heteroscedastic pattern is introduced to analyze stochastic regression relationship between the two time series. Nonlinear ARCH concept is incorporated into the TFM via threshold ARCH and beta- ARCH models. Steps for statistical analysis of the proposed model are explained along the lines of the Box & Jenkins(1976, ch. 10). For illustration, dynamic analysis between KOSPI and NASDAQ is conducted from which it is seen that threshold ARCH performs the best.

Molecular epidemiologic analysis of pathogenic Escherichia coli isolated from poultry in Korea (국내 가금 유래 병원성 대장균의 분자역학적 분석)

  • Sung, Myung-Suk;Kim, Jin-Hyun;Kim, Ki-Seuk
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.3
    • /
    • pp.239-246
    • /
    • 2010
  • Among 203 avian pathogenic Escherichia coli (APEC) isolated from poultry with colibacillosis in korea, 14 isolates were selected from total 68 isolates transferred R plasmid and classified into 5 groups on the basis of antimicrobial minimal inhibitory concentration (MIC) pattern, farm source and O serotype. An association between clonal origin and R plasmid of them was investigated by R plasmid profile, restriction endonuclease analysis and pulsed-field gel electrophoresis (PFGE). The strains that showed the same or very similar antimicrobial MIC pattern, but different farm source and O serotype, revealed different PFGE pattern, which seemed to be different clonal origin. And the strains that showed the same MIC pattern and O serotype, revealed different PFGE pattern, seemed to be originated from different clone. Also the strains showing the same MIC pattern and farm source, but different O serotype, revealed to be different clonal origin. The strains that showed the same or similar MIC pattern, farm source, and O serotype, revealed identical or similar PFGE pattern, which seemed to belong to be one clone. Meanwhile, horizontal transfer of R plasmid seems to be common in APEC with regardless of O serotype and clone of the strains. These results indicate that rapid and accurate epidemiological survey of APEC can be possible by the combination of O serotyping, plasmid profiling and PFGE analysis following the classification of them into groups of antimicrobial drug resistance pattern.

Analysis of Underwater Acoustic Radiation of SWATH vessel using Transfer Function Method (전달함수법을 이용한 SWATH선의 수중 음향 방사 해석)

  • 김재호
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.20-34
    • /
    • 2003
  • The good sea-keeping capability of the SWATH(Small Waterplane Area Twin Hull) ship has been attractive for research or surveillance vessels. Especially, for the naval ships accomplishing the underwater acoustic missions, it is necessary to access and minimize the underwater radiated noise level generated by the ships. Therefore, acoustic signature management and control are very important topics for these vessels. Underwater radiation pattern in the low frequency range is dominated by the tonals from the vibration of onboard machinery. In this work, the radiated noise level generated by the propulsion machine in the submerged hull is predicted using the transfer function technique and the hull transfer function for the submerged hull is determined by analyzing the longitudinal/circumferential stiffened infinitely long cylindrical shell and considering the empirical database of the previous vessels. It is confirmed that the transfer function technique can give useful information for identifying the noise source and estimating its contribution to the total radiatied noise level.

Numerical Analysis on Heat Transfer and Fluid Flow Characteristics of Traction Motor for Electric Car (전동차용 견인전동기의 열유동 특성에 관한 전산해석)

  • 남성원;김영남;채준희
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.137-143
    • /
    • 1998
  • Numerical simulation is conducted to clarify the heat transfer and fluid flow characteristics of traction motor for electric car SIMPLE algorithm based on finite volume method is used to make linear algebra equation. The governing equations are solved by TDMA(TriDiagonal Matrix Algorithm) with line-by-line method and block correction. From the results of simulation, the characteristics of cooling pattern is strongly affected by the size of hole in stator core. In the case of high rotational speed of rotor, temperature difference along the axial direction is more decreased than that of low rotational speed.

  • PDF

Numerical Analysis for the Unsteady Laminar Flow and Heat Transfer Around a Circular Cylinder (원주 주위의 비정상 층류유동과 열전달에 대한 수치해석)

  • 조석호;남청도;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.64-72
    • /
    • 1991
  • The unsteady, two-dimensional laminar flow and heat transfer of an incompressible, constant-property fluid flowing around a circular cylinder are numerically analyzed. The Navier-Strokes equation and the energy equation are solved by the finite difference method. The range of the Reynolds number is 10 to 100 and the Prandtl number considered is 0.7. The contours of the flow pattern, equi-vorticity line and isotherm pattern around a circular cylinder are shown. Also, numerical solutions of the surface vorticity, pressure coefficient, drag coefficient, local Nusselt number and mean Nusselt number are obtained. The numerical results for the final time fo calculation are compared with the other available experimental and theoretical results for the steady state and are found to be in good agreement with them.

  • PDF

CO Adsorption on Three-Dimensional and Multilayered Platinum Electrode Prepared through Transfer Printing (전사 인쇄에 의한 3D와 다층의 Pt 전극의 CO가스 흡착)

  • Jeong, Yoon-Seo;Choi, You-Jeong;Shin, Jeong-Hee;Jeong, Young-Hun;Paik, Jong-Hoo;Yoon, Dae-Ho;Cho, Jeong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.232-236
    • /
    • 2020
  • Three-dimensional (3D) multilayered Pt electrodes were fabricated to develop a porous electrode using a pattern-transfer printing process. The Pt thin films were deposited using a transferred sputtering pattern having a 250 nm line width on the substrate, and the uniform line patterns were efficiently transferred using our proposed method. Temperature-programmed desorption (TPD) analyses were used to evaluate the porosity of the electrodes. It was possible to distinguish between two resolved maxima at 168 and 227 ℃, which could be described in terms of desorption reactions on the Pt (111) planes. The results of the TPD analysis of the 3D and multilayered Pt electrodes prepared through transfer printing were compared to those of an electrode fabricated through screen printing using a commercial Pt-carbon paste commonly used as porous electrodes. It was confirmed that the 3D multilayered electrodes exhibited a desorption concentration approximately 100 times higher than that of the Pt-carbon composite electrode, and the desorption concentration increased by approximately 0.02 mg/mol per layer. The 3D multilayered electrode effectively functions as a porous electrode and a catalyst.

Experimental measurements of R-22 two-phase friction factor in plate heat exchangers (판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가)

  • Yoo, Sang-Roon;Jeong, Ji-Rwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF

Analysis on the Thermal Performance of an Ammonia Unit Cooler (암모니아 유니트 쿨러의 열성능 해석)

  • 최재광;김무근;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1125-1133
    • /
    • 2001
  • Since the surface temperature of the evaporating tube in an ammonia unit cooled is lower than the dew point of atmosphere, the moisture in the atmosphere condenses and the frost grows on the tube. The frost of liquid film decreases the heat transfer rate. The reliable analysis of the heat transfer is required for the prediction of the optimal design of the ammonia unit cooler. For the specific commercial model, the performance was numerical1y estimated for the variation of operating condition and geometric configuration. It is found that there exists an optimum range for the parameters such as mass flow rate of air and refrigerant, humidity, refrigerant quality, fin pitch, the number of step, the number of rows and the pattern of refrigerant path.

  • PDF

Factor Analysis for Transit Transfer using Public Traffic Card Data (대중교통카드를 이용한 환승요인분석)

  • Lee, Da-Eun;Oh, Ju-Taek
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.1
    • /
    • pp.50-63
    • /
    • 2017
  • While transit is inconvenient, it is also inevitable for the efficient public transportation. Reducing the number of transfers as much as possible is most important in providing the convenience of public transportation and facilitating the public transportation. As for the public transportation card data, 61,986 items on weekdays and 69,100 items on weekends were collected. Pattern analysis and traffic influence factors were analyzed using traffic data card. Trip chain results revealed that people have more transit transfers for shopping and leasure than commuting purposes on weekends and that commuting distance and time increase by 10 km and 9.9 minutes, respectively. Besides, results of the structural equation model showed that factor 1(total travel time, total travel distance), factor 2(number of people getting on and off), factor 3(transit time), and factor 4(number of bus connections, number of operations) were found to have significant effects on the number of transfers.