• 제목/요약/키워드: Transfer Film

검색결과 1,079건 처리시간 0.03초

낮은핀관의 액막 증발 촉진에 관한 연구 (Enhancement of thin film evaporation on low-fin tubes)

  • 김내현
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.674-682
    • /
    • 1998
  • In this study, thin film evaporation of water on low-fin tubes were experimentally investigated. Five low-fin tubes with different fin spacing and fin height were tested. Test range covered 0.146kg/ms $\leq$$\Gamma$$\leq$0.219kg/ms and 10㎾/$\m^2$$\leq$q $\leq$70㎾/$\m^2$. Saturation temperature was loot. Compared with the plain tube, low fin tubes enhanced the water film evaporation from 60% to 100%. Tubes with fin spacing smaller than 2mm and fin height higher than 1mm performed better than tubes with other fin configuration. However, when fin spacing was too small at high film flow or fin height was too high at low film flow, the performance decreased. The heat transfer coefficient slightly increased as the flow rate increased. Correlations are developed based on present data.

  • PDF

ESTIMATION OF LOCAL LIQUID FILM THICKNESS IN TWO-PHASE ANNULAR FLOW

  • Lee, Bo-An;Yun, Byong-Jo;Kim, Kyung-Youn;Kim, Sin
    • Nuclear Engineering and Technology
    • /
    • 제44권1호
    • /
    • pp.71-78
    • /
    • 2012
  • In many semi-empirical analyses of flow boiling heat transfer, an annular flow is often assumed as a model flow and the local liquid film thickness is a key parameter in the analysis. This work considers a simple electrical conductance technique to estimate the local liquid film thickness in two-phase annular flows. In this approach, many electrodes are mounted flush with the inner wall of the pipe. Voltage differences between two neighboring electrodes for concentric annular flows with various liquid film thicknesses are obtained before the main experiments and logged in a look-up table. For an actual application in the annual flow, voltage differences of neighboring electrodes are measured and then corresponding local film thicknesses are determined by the interpolation of the look-up table. Even though the proposed technique is quite simple and straightforward, the numerical and static phantom experiments support its usefulness.

슬러지 박막의 건조과정에 대한 건조 특성 해석 (Analysis on the Drying Characteristics for the Drying Process of a Thin Film Layer of Sludge)

  • 이공훈;김욱중
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1128-1133
    • /
    • 2008
  • Drying process in the thin film layer of sludge with the thickness less than a few millimeters has been investigated using the simple one-dimensional model. Thin film drying is usually used to dry the viscous materials like sewage sludge. The thin film layer of sludge is dried on the metallic surface through which thermal energy is supplied to the layer during drying. In order to solve the equations, the mass transfer rate on the drying surface should be determined. The mass flux of evaporated water vapor on the surface is estimated with the formulation given in the literature. The effect of heating temperature, film thickness, and air velocity on drying has been examined to figure out the drying characteristics of the sludge layer.

  • PDF

내부와 외부에서 증발과 응축이 발생하는 수직관에 대한 유동 해석 (Film Flow Analysis for a Vertical Evaporating Tube with Inner Evaporation and Outer Condensation)

  • 박일석
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.621-628
    • /
    • 2008
  • A numerical study for the flow, heat and mass transfer characteristics of the evaporating tube with the films flowing down on both the inside and outside tube walls has been carried out. The condensation occurs along the outside wall while the evaporation occurs at the free surface of the inside film. The transport equations for momentum and energy are parabolized by the boundary-layer approximation and solved by using the marching technique. The calculation domain of 2 film flow regions (evaporating and condensation films at the inside and outside tube wall respectively) and tube wall is solved simultaneously. The coupling technique for the problem with the 3 different regions and the 2 interfaces of them has been developed to calculate the temperature field. The velocity and temperature fields and the amount of the condensed and evaporated mass as well as the position where the evaporating film is completely dried out are successfully predicted for various inside pressures and inside film inlet flow rates.

운모기판을 이용한 다결정 Si 전이막 성장 연구 (Growth of Transferable Polycrystalline Si Film on Mica Substrate)

  • 박진우;엄지혜;안병태;정영권
    • 한국재료학회지
    • /
    • 제14권5호
    • /
    • pp.343-347
    • /
    • 2004
  • We investigated the growth feasibility of polycrystalline Si film on mica substrate for the transfer of the layer to a plastic substrate. The annealing temperature was limited up to $600^{\circ}C$ because of crack development in the mica substrate. Amorphous Si film was deposited on mica substrate by PECVD and was crystallized by furnace annealing. During the annealing, bubbles were formed at the Si/mica interface. The bubble formation was avoided by the Ar-plasma treatment before amorphous Si deposition. A uniform and clean polycrystalline Si film was obtained by coating $NiCl_2$ on the amorphous Si film and annealing at $500^{\circ}C$ for 10 h. The conventional Si lithography was possible on the mica substrate and the devices fabricated on the substrate could be transferred to a plastic substrate.

Thin CNTs nanoliquid film development over a rough rotating disk

  • Swatilekha Nag;Susanta Maity;Sanjeev K. Metya
    • Advances in nano research
    • /
    • 제15권2호
    • /
    • pp.91-104
    • /
    • 2023
  • Development of thin carbon nanotubes (CNTs) nanoliquid film over the rough surface of a horizontal rotating disk is investigated by considering symmetric roughness either along the azimuthal or radial directions. The disk surface is either heated or cooled axisymmetrically from below. The effects of single-walled carbon nanotubes (SWCNTs), multi-walled carbon nanotubes (MWCNTs) are analyzed on the film thinning process with different types of base liquids. Closed form solutions for velocity and temperature field are obtained for small values of Reynolds number whereas the numerical solution is derived for moderate values of Reynolds number. It is found that fluid retention / depletion takes place when the roughness is symmetric along the azimuthal / radial directions. It is also seen that the film thinning rate enhances for MWCNTs compare to SWCNTs. Further it is found that two different heat transfer regions exits within the flow domain depending on the fact that heat is transferred from disk to liquid film and vice-versa.

접촉각이 유하액막 특성에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effects of Contact Angle on a Falling Liquid Film)

  • 김경희;강병하;이대영
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.867-873
    • /
    • 2006
  • Vertical falling liquid film is extensively used in heat and mass transfer processes of many applications, such as evaporative coolers, cooling towers, and absorption chillers. In such cases, it is required that the falling film spreads widely in the surface forming thin liquid film to enlarge contact surface. An addition of surface active agent to a falling liquid film or hydrophilic surface treatment affects the fluid physical properties of the film. Surfactant addition not only decreases contact angle between the liquid and solid surface but also changes the surface from hydrophobicity to hydrophilicity. In this study, the effects of contact angle on falling film characteristics over a vertical surface have been investigated experimentally. The contact angle is varied either by an addition of surfactant to the liquid or by hydrophilic surface treatment. It is found that the wetted area is increased and film thickness is decreased by the hydrophilic treatment as compared with those of other surfaces. With this hydrophilic treatment, the falling liquid film spreads out widely in the surface. As surfactant concentration is increased, wetted area is also increased and the film thickness is substantially decreased.