• Title/Summary/Keyword: Transfer Curves

Search Result 290, Processing Time 0.029 seconds

Performance analysis of a scroll compressor considering quasi one-dimensional leakage modeling and heat transfer loss (준 1차원 누설모델링 및 열전달 손실을 고려한 스크롤압축기의 성능해석)

  • Gang, Tae-Gyu;Park, Gyeong-U;Jeong, Yeon-Gu;Park, Hui-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1339-1349
    • /
    • 1997
  • A numerical method of calculating the performance of a scroll compressor for refrigerant R-22 and R-134a is presented in this paper. A series of involute curves are employed for the scroll wrap design and the compression volume is investigated geometrically. The radial leakage flow rate through tip clearance is calculated by the two-dimensional compressible flow. On the basis of the results, quasi one-dimensional leakage modeling can be applied to the performance analysis of a scroll compressor, more effectively. Furthermore, the heat transfer effect between scroll wrap and working fluid in compression chamber is considered for the performance analysis. As the results of this study, the effects of the radial and tangential leakage flow rate and heat transfer on the scroll compressor performance are derived precisely. These results may provide the guideline for the design and development of a real scroll compressor.

Experimental study on the influence of heating surface inclination angle on heat transfer and CHF performance for pool boiling

  • Wang, Chenglong;Li, Panxiao;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.;Deng, Jian
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.61-71
    • /
    • 2022
  • Pool boiling heat transfer is widely applied in nuclear engineering fields. The influence of heating surface orientation on the pool boiling heat transfer has received extensive attention. In this study, the heating surface with different roughness was adopted to conduct pool boiling experiments at different inclination angles. Based on the boiling curves and bubble images, the effects of inclination angle on the pool boiling heat transfer and critical heat flux were analyzed. When the inclination angle was bigger than 90°, the bubble size increased with the increase of inclination angle. Both the bubble departure frequency and critical heat flux decreased as the inclination angle increased. The existing theoretical models about pool boiling heat transfer and critical heat flux were compared. From the perspective of bubble agitation model and Hot/Dry spot model, the experimental phenomena could be explained reasonably. The enlargement of bubble not only could enhance the agitation of nearby liquid but also would cause the bubble to stay longer on the heating surface. Consequently, the effect of inclination angle on the pool boiling heat transfer was not conspicuous. With the increase of inclination angle, the rewetting of heating surface became much more difficult. It has negative effect on the critical heat flux. This work provides experimental data basis for heat transfer and CHF performance of pool boiling.

Modeling Study on Nuclide Transport in Ocean - an Ocean Compartment Model (해양에서의 핵종이동 모델링 - 해양구획 모델)

  • Lee, Youn-Myoung;Suh, Kyung-Suk;Han, Kyong-Won
    • Nuclear Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.387-400
    • /
    • 1991
  • An ocean compartment model simulating transport of nuclides by advection due to ocean circulation and intertaction with suspended sediments is developed, by which concentration breakthrough curves of nuclides can be calculated as a function of time. Dividing ocean into arbitrary number of characteristic compartments and performing a balance of mass of nuclides in each ocean compartment, the governing equation for the concentration in the ocean is obtained and a solution by the numerical integration is obtained. The integration method is specially useful for general stiff systems. For transfer coefficients describing advective transport between adjacent compartments by ocean circulation, the ocean turnover time is calculated by a two-dimensional numerical ocean model. To exemplify the compartment model, a reference case calculation for breakthrough curves of three nuclides in low-level radioactive wastes, Tc-99, Cs-137, and Pu-238 released from hypothetical repository under the seabed is carried out with five ocean compartments. Sensitivity analysis studies for some parameters to the concentration breakthrough curves are also made, which indicates that parameters such as ocean turnover time and ocean water volume of compartments have an important effect on the breakthrough curves.

  • PDF

Rabi Oscillation between States of a Coupled Harmonic Oscillator

  • Park, Tae-Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.2
    • /
    • pp.219-221
    • /
    • 2003
  • Rabi oscillation between bound states of a single potential is well known. However the corresponding formula between the states of two different potentials has not been obtained yet. In this work, we derive Rabi formula between the states of a coupled harmonic oscillator which may be used as a simple model for the electron transfer. The expression is similar to typical Rabi formula for a single potential. This result may be used to describe transitions between coupled diabatic potential curves.

The Effect of Tube Orientation on Pool Boiling Heat Transfer (튜브 설치 방향이 풀비등 열전달에 미치는 영향)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.143-151
    • /
    • 2000
  • In order to clarify the effect of tube orientation on pool boiling heat transfer, the experiments were carried out for the saturated pool boiling of water at atmospheric pressure. Through the tests a series of data sets for heat flux versus wall superheat has been obtained using various combinations of tube diameters (D=9.7 $\~$25.4mm), surface roughness ($\varepsilon$=15.1$\~$60.9nm), and tube orientations (horizontal and vertical). ηei experimental results show that the slope of heat flux versus wall superheat becomes smaller than that of the horizontal tube as the surface roughness decreases from $\varepsilon$=60.9 to $\varepsilon$=15.1nm. Such that, two curves for the horizontal and vertical tubes cross each other in accordance with surface roughness and the crossing point can be suggested as q" = ‘-4.768+1.334$\varepsilon$+0.055${\varepsilon}^2$.

An Experimental Study on the Evaporation and Ignition of CWS Droplets (CWS액적의 증발 및 점화에 관한 실험적 연구)

  • 안국영;백승욱;김관태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1246-1252
    • /
    • 1993
  • Coal-Water slurry (CWS) is a new potential form of fuel for use in power plants and industrial furnaces. The evaporation and ignition characteristics of CWS have been studied in the post-flame region generated by a flat flame burner. Individual droplets with initial diameters of 1-3mm were supported around the thermocouples and raidly exposed to a hot gas stream. The gas temperature ranged between $950^{\circ}C$ and 1600.deg. C at atmospheric pressure. The effect of droplet size, gas temperature and radiative heat transfer by screen were studied experimentally. The ignition criterion was either a rapid temperature rise in time-temperatuire curves or onset of visible flame in experiment. Incresing the gas temperature or decreasing the droplet size reduced the time required for evaporation and ignition.

Improvement of Electrochemical Reaction Kinetics in Lithium Manganese Oxide Thin Films (리튬 망간산화물 박막에서의 전극 반응의 개선)

  • Park Young-Shin;Kim Chan-Soo;Joo Seung-Ki
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.2
    • /
    • pp.96-99
    • /
    • 2000
  • In order to improve the rate capability of lithium manganese oxide thin film, we prepared the patterned cathode films by conventional lithography and etching techniques. From the investigation of discharge current density effects on discharge curves of cathode films, the rate capability was greatly improved due to increase of lithium intercalation kinetics fur charge transfer.

Boiling Heat Transfer from a locally Heated Surface -A Simulated Electronic Device under Liquid Immersion Cooling- (국부적인 발열부분을 가진 표면에서의 잠김 비등열전달 -전자부품 액침 냉각에서의 응용-)

  • 하광순;최상민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.685-692
    • /
    • 1991
  • The pool boiling behavior of a heated surface has been investigated experimentally, focusing on the cases when only a part of the contact surface is heated. Characteristic boiling curves are obtained with circular metal surface test pieces heated below while immersed in Refrigerant-113. Locally heated test pieces are fabricated by inserting a heating block at the center inside a larger conducting block. Overall heat transfer rates are measured while the experimental conditions are systematically varied. The local temperature profiles along the radius are measured for conducting blocks. It is found that the conjugated boiling condition exists and the total heat fluxes should be correlated to a suitably defined temperature difference.

Stress Estimation of a Drain Current in Sub-threshold regime of amorphous Si:H

  • Lee, Do-Young;Lee, Kyung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1172-1175
    • /
    • 2007
  • We have investigated the threshold voltage shifts(${\Delta}Vth$) and drain current level shift (${\Delta}Ids$) in subthreshold region of a-Si:H TFTs induced by DC Bias (Vgs and Vds) - Temperature stress (BTS) condition. We plotted the transfer curves and the ${\Delta}Vth$ contour maps as Vds-Vds stress bias and Temperature to examine the severe damage cases on TFTs. Also, by drawing out the time-dependent transfer curve (Ids-Vgs) in the region of $10^{-8}\;{\sim}\;10^{-13}$ (A) current level, we can estimate the failure time of TFTs in a operating condition.

  • PDF