• 제목/요약/키워드: Transducer array

검색결과 198건 처리시간 0.023초

횡파 위상배열 초음파탐촉자를 이용한 원자력발전소 저압 터빈 검사 적용 타당성 연구 (Feasibility Study for Low Pressure Turbine Inspection of Nuclear Power Plant Using Shear Wave Phased Array Ultrasonic Transducer)

  • 윤병식;김용식;김진회
    • 한국압력기기공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.8-14
    • /
    • 2013
  • Steam turbine blades and discs of nuclear power plants are one of the most highly stressed areas of turbine rotor, and periodic inspection of the blade roots is essential for monitoring integrity and preventing turbine failure. Ultrasonic technique is applied for volumetric inspection of blade root. However, the complexity of blade root geometry imposes challenges to inspection of blades and discs. Recently, phased array ultrasonic inspection technology is being applied to numerous power generation inspection applications including turbine rotor. The phased array ultrasonic technique requires customized inspection wedges which are generally necessary to generate effectively higher incident angle. But the usage of this wedge can cause access limitation for the lower stage blades of turbine because of the wedge front length. Therefore, the shear wave phased array probe which can generate high inspection angle without wedge is essentially necessary. In this study, feasibility study is conducted for the shear wave phased array ultrasonic probe application to blade and disc inspection. As results, the experimental results show that the shear wave phased array probe can detect the flaw and measure its size with reliable accuracy. Therefore if this shear wave phased array probe is applied to field inspection of blade and disc, more reliable inspection is expected for turbine having access limitation.

선형 트랜스듀서를 이용한 혈관 변형률 영상법 (Blood Vessel Strain Imaging Using Linear Array Transducer)

  • 안동기;정목근
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.880-890
    • /
    • 2010
  • 뇌졸중 등의 혈관 질병을 진단하기 위해서 혈관 내 초음파(Intravascular Ultrasound:IVUS)영상 기법이 사용되고 있다. 최근에는 혈관 내벽에 붙은 혈전을 탄성 영상법을 이용하여 진단하는 방법들이 연구되고 있다. 그러나 혈관 내 초음파는 혈관 내에 트랜스듀서를 삽입하여야 하므로 진단 방법에 위험성이 있다. 본 논문은 선형 트랜스듀서를 이용하여 혈관 외부에서 데이터를 획득하여 혈관 내벽에 붙은 혈전의 변형률 영상을 얻었다. 혈관 벽의 움직임을 정확하게 측정하기 위하여, 혈관 벽과 수직이 되도록 주사선의 방향을 조향하면서 초음파 데이터를 획득하였다. 초음파 데이터는 기저대역의 복소수 신호로 복조한 뒤 자기상관(autocorrelation)을 이용하여 혈관 벽의 움직임을 계산하여 변형률 영상을 얻었다. 제안한 방법을 플라스틱 기반의 혈관 모사 팬텀을 제작하여 검증하였다. 혈관 모사 팬텀은 혈관에 해당하는 직경 6mm의 실린더 공간에 물을 채우고 벽을 따라 2mm 두께의 부드러운 혈전을 혈관 벽의 내부에 배치하였다. RF 데이터는 상용 초음파 진단기에서 7.5MHz 선형 트랜스듀서를 사용하여 -40도부터 40도까지 1도 간격으로 조향시킨 81개의 스캔라인 데이터를 얻었다. 실험 결과 단단한 배경 팬텀에 인접한 혈전 영역이 더 무른 것으로 관찰되었다. 제안한 방법의 탄성 영상법이 비록 주사선이 혈관 벽에 수직으로 입사하는 영역으로 제한되지만 혈관 변형률 영상법의 유용함을 실험으로 입증하였다.

횡파 위상배열 초음파 탐촉자 설계 및 성능 평가 (Design and Performance Evaluation of Shear Wave Phased Array Ultrasonic Transducer)

  • 윤병식;이희종
    • 비파괴검사학회지
    • /
    • 제32권2호
    • /
    • pp.185-191
    • /
    • 2012
  • 일반적으로 위상배열 초음파검사 기법을 이용한 배관 용접부검사에서는 높은 검사 각도를 효과적으로 발생하기 위하여 ��지를 사용하게 된다. 그러나 용접부 또는 접근이 제한된 부위에 대한 검사는 위상 배열 초음파 탐촉자에 ��지를 부착하게 되면 ��지의 전단 길이로 인하여 검사체적을 포함하지 못하는 등의 문제점이 발생하게 된다. 따라서 ��지를 사용하지 않고 높은 검사 각도를 발생할 수 있는 횡파 위상배열 초음파 탐촉자를 적용해야 할 필요성이 있다. 본 연구에서는 굴절각도가 높은 횡파를 발생할 수 있는 위상배열 초음파 탐촉자를 설계하고 제작하여 다양한 깊이의 EDM 노치가 가공된 시험편에서 결함이 정확하게 검출되고 평가될 수 있는 지를 확인하였다. 결과적으로 본 연구에서 설계된 횡파 위상배열 초음파 탐촉자는 다양한 깊이의 결함을 검출하고 신뢰성 있는 정밀도를 나타내었으므로 향후 접근제한이 예상되는 발전설비 구조물의 검사에 적용된다면 효과적인 검사 결과를 보여줄 것으로 기대된다.

40-75 kHz의 주파수 범위에서 동작하는 광대역 초음파 변환기의 설계 및 개발 (Design and Development of a Broadband Ultrasonic Transducer Operating over the Frequency Range of 40 to 75 kHz)

  • 이대재;곽민선;강희영
    • 한국수산과학회지
    • /
    • 제47권3호
    • /
    • pp.292-301
    • /
    • 2014
  • The objective of this study was to design and develop a broadband ultrasonic transducer that has both wide bandwidth and high sensitivity to measure broadband echoes related to identifying fish species. A broadband ultrasonic transducer providing a nearly flat transmitting response band of 40.2-75.5 kHz with a -12 dB bandwidth of 35.3 kHz was achieved by integrating 12 tonpilz transducer elements operating at different resonance frequencies. The average transmitting voltage response, receiving sensitivity, and figure of merit values in this frequency band were 168.4 dB (re $1{\mu}Pa/V$ at 1 m), -196.8 dB (re $1V/{\mu}Pa$), and -28.4 dB, respectively. The results suggest that bandwidth and sensitivity can be widened and improved by adjusting the array pattern and the structure of tonpilz transducer elements.

유한요소법과 하이브리드형 무한요소법의 결합에 의한 축대칭 변환기의 음향 특성해석 ( I ) ; 방사임피던스, 지향성 및 압전자간의 결합효과 (Acoustic Characteristics Analysis of the Axi-symmetric Transducer by the combined Finite Element Method and Hybrid Type Infinite Element Method, Part I ; Radiation Impedance, Directivity and Transducer Coupling Effect)

  • 윤종락;윤형규;김대환;김천덕
    • 한국음향학회지
    • /
    • 제13권2호
    • /
    • pp.60-67
    • /
    • 1994
  • 본 논문은 두 편으로 연결된 논문의 첫 논문으로 무한음향 매질내의 축대칭음향 변환기 음향특성 해석을 위한 유한요소법과 하이브리드형 무한요소법의 결합 알고리즘을 제시하고 이를 이용한 음향변환기의 방사 임피던스, 지향성 및 압전자간의 결합 효과에 대한 수치해석 결과를 제시하였다. 두번째 논문에서는 첫논문의 결과를 기초로 광대역 배역 변환기를 설계하고 설계된 변환가의 음향특성을 해석하였다.

  • PDF

레이저 유도방식의 실시간 광음향 단층영상 기술 개발과 팬텀이미지 평가 (Development of Laser Induced Real Time Photoacoustic Tomography Imaging System and Phantom Evaluation)

  • 유상훈;신동호;송철규
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.879-884
    • /
    • 2012
  • Photoacoustic Tomography (PAT) is a promising medical imaging modality by reason of its particularity. It combines optical imaging contrast of optical imaging with the spatial resolution of ultrasound imaging and can demonstrate change of biological feature in an image. For that reason, many studies are in progress to apply this technic for diagnosis. But, real-time PAT system is necessary to confirm a biological reaction induced by external stimulation immediately. Thus, we developed a real-time PAT system using linear array transducer and self-developed Data acquisition board (DAQ) resources, To evaluate the feasibility and performance of our proposed system, two type of phantom test were also performed. As a result of those experiments, the proposed system shows enough performance and confirm its usefulness.

마이크로 PMMA몰드를 이용한 1-3 PZT Composite제조 (Preparation of 1-3 PZT Composites Fabricated Using Micro PMMA Mold)

  • 박준식;조진우;정석원;박순섭;이선호;김동현;한진호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권6호
    • /
    • pp.271-275
    • /
    • 2001
  • We investigated preparation of 1-3 PZT composites for medical ultrasonic transducer array (briefly UTA) using micro pressing method. The proposed process was using pressing PZT green sheet by PMMA micro mold obtained from X-ray lithography. Microstructures, electriacl and electro-mechanical properties of fabricated composites were analyzed. Dielectric constant at 1kHz and thickness mode electro-mechanical coupling coefficient of $6.2mm{\times}6.2mm{\times}422{\mu}m$ UTA sample were 1754 and 51%, respectively. Microstructures of sintered PZT showed dense and uniform. And PZT phases were well crystallized. Micro pressing method is a mass productive process in case of using injection molded PMMA by batch type LIGA process.

  • PDF

트랜스포머에 의한 수중 음향 트랜스듀서의 송수신 특성의 변화 (Changes in Transmitting-Receiving Characteristics of Underwater Acoustic Transducer by Transformer)

  • 조치영;이정민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.493-499
    • /
    • 1997
  • In this study, the changes in transmitting and receiving characteristics, especially resonance frequencies, of the underwater acoustic planar array transducer by the transformers used in the analog weighting circuit are investigated. Electrical equivalent circuit analysis shows that an ideal transformer does not change the resonance frequency of the transmitting mode, but the resonance frequency which gives the maximum receiving sensitivity can be designed by adjusting the magnitude of reactance of transformer.

  • PDF

속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합 (Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging)

  • 김영훈;박관규
    • 비파괴검사학회지
    • /
    • 제36권1호
    • /
    • pp.27-34
    • /
    • 2016
  • 본 논문은 초음파를 이용한 단층촬영(ultrasound computed tomography, UCT)을 위해 사용되는 영상 복원 방식에서 실제 사용되는 초음파 트랜스듀서의 조합에 따른 영항을 다루었다. 촬영 대상의 속도 분포를 구하기 위해서 라돈 변환(radon transform)을 사용하였으며, 음향 임피던스의 영상화를 위하여, 시간지연(delay and sum)방식을 사용하였다. 음향 임피던스 영상의 경우 속도 분포 영상에 의해 보정하여 더 정확한 영상을 복원하였다. 매질의 특성에 따른 감쇠, 굴절 및 반사를 고려한 초음파 시뮬레이터로 128개의 환형 트랜스듀서 어레이를 구현하였으며, 5 MHz의 중심주파수로, 5 cm의 인체조직 영상을 구현하였다. 실제 구현을 위한 최적의 트랜스듀서 조합을 찾기 위해, 점 진원(point source), 평면 트랜스듀서(flat transducer), 집속 트랜스듀서(focused transducer)를 이용해서 속도 분포에 대한 영상과 음향 임피던스 영상을 구현하여 비교하였다. 또한 시뮬레이션 상에서는 송신 및 수신 트랜스듀서가 모두 점 트랜스듀서인 경우가 가장 좋은 결과를 보여주었으나, 실제 구현을 고려하면 송신은 평면 트랜스듀서가 수신은 점 트랜스듀서로 하는 조합이 가장 현실적으로 좋은 결과를 보여준다.

광대역 초음파 장 응답의 해석과 집속된 Annular Array 영상 시스템 설계에의 응용 (Analysis of Broadband Ultrasonic Field Response and its Application to the Design of Focused Annular Array System)

  • 노경태;송태경;박송배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1252-1255
    • /
    • 1987
  • In this paper an approach for the analysis of the transient field response of radially symmetric transducer due to a wideband ultrasonic pulse is presented, which is based on a development of Green's function and applies the linear system theory to obtain an analytic expression for the impulse response of an annulus with a planar or spherical geometry. For the focused annular array, the impulse responses of the indivisual annuli are convolved with the delayed excitation pulse, and then summed to obtain the resultant response of the array. This process is very effective in the study of the various focusing abilities of the annular array. For illustration, the field distribution of a five element annular array is treated in detail for several focusing system.

  • PDF