• Title/Summary/Keyword: Transducer array

Search Result 198, Processing Time 0.025 seconds

Analysis of the Ultrasonic Beam Profile Due to Variation of the Inter-Element Spacing for the Phased Array Transducer (페이즈드 어레이 트랜스듀서에 있어서 구성 압전소자의 간격 변화에 따른 초음파 빔 전파 특성 해석)

  • Choe, Sang-U;Lee, Jun-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.972-981
    • /
    • 2000
  • The phased array transducer has two distinct advantages. One is rapid scanning comparing with the conventional mechanical or manual scanning system. Therefore, output image is represented in real-time. The other is the dynamic focusing and the dynamic steering of ultrasonic beam. Only the delay times that are controlled electrically are used to focus and to steer beam without any lenses or wedges. In this study, the profile of the ultrasonic beam for the phased array transducer has been simulated in the Huygens principle with varying the inter-element spacing of the linear phased array transducer. From the result of this study, it was found that the ultrasonic beam spread wider as the inter-element spacing was decreased. However, the focusing effect was improved, even when the number of the element was not big. In addition, there was grating lobes that are constructed when the inter-element spacing is more than half wavelength. However, this grating lobe has lower amplitude than the main lobe.

Basic Experiment for Lamb Wave Focusing by Phased Magnetostrictive Transducers in a Plate (자기변형 트랜스듀서의 위상차를 이용한 평판에서의 Lamb파 집속 기초 실험)

  • Lee, Joo-Kyung;Kim, Hoe-Woong;Lee, Ho-Cheol;Kim, Yoon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.3
    • /
    • pp.227-233
    • /
    • 2011
  • The ultrasonic guided wave phased array using magnetostrictive patch transducers is proposed. The magnetostrictive transducer has received much attention because it is cost-effective and capable to generate ultrasonic waves with a simple configuration. However, it has not been used for ultrasonic guided wave phased array applications until now. In this paper, we propose a magnetostrictive transducer based phased array system consisting of a multi-channel function generator, power amplifiers and Lamb wave magnetostrictive transducers. To check the performance of the ultrasonic guided wave phased array, several Lamb wave focusing experiments were carried out in an aluminum plate. The results demonstrated the capability of the developed array to focus the Lamb waves at specific target points.

Design and Fabrication of a 2D Array Ultrasonic Transducer (2D 배열형 초음파 트랜스듀서의 설계 및 제작)

  • Lee, Wonseok;Woo, Jeongdong;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.393-401
    • /
    • 2013
  • In this paper, a $48{\times}64$ channel 2D array ultrasonic transducer with piezoelectric single crystals was designed, fabricated, and evaluated. Structure of the transducer was chosen to facilitate the electric connection on the planar array, and then components were fabricated in accordance with the structure. Detailed structure of the transducer was designed through finite element analyses. In order to improve the performance of the transducer, the crosstalk between adjacent elements was reduced through the control of kerf width and material, and the target frequency bandwidth was achieved through optimal design of the thickness of the single crystal and matching layers. After fabricating a prototype of the transducer according to the design and measuring its characteristics, the results were compared with those of finite element analyses to evaluate the performance of the developed transducer.

Ultrasonic Transducers for Medical Volumetric Imaging

  • Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.3E
    • /
    • pp.111-118
    • /
    • 2010
  • Three-dimensional ultrasound imaging is a new, exciting technology that allows physicians to use ultrasound to view pathology as a volume, thereby enhancing comprehension of patient anatomy. In this paper, a brief history of the 3-D ultrasound imaging is described in accordance with the development of transducer technology. Then, two representative types of 3-D imaging transducers are reviewed with description of the concept and operation principle of each type: mechanical transducer and matrix array transducer. The mechanical transducer is detailed into free-hand scanning and sequential scanning types. Advantages of each transducer over the other and the technical issues for further performance enhancement are also presented.

A transducer array for focusing the ultrasound setting angle (초음파 집속을 위한 트랜스듀서 어레이 집속 각도 설정)

  • Lee, Sang-sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.1
    • /
    • pp.45-48
    • /
    • 2016
  • The treatment of obesity have been developed various devices for the treatment of obesity, the ultrasound is to be made after the state changes to become easy fat decomposition by heat and vibrations to facilitate the flow of blood and lymph fatty acid released into the blood. There is such ultrasonic transducer array is used in obesity therapy focusing angle of the transducer array and the frequency may have a significant impact on the degradation of fat. In this paper, we set the frequency that reaches the shortest time to a set temperature 27kHz, 1MHz, by applying a transducer with a diameter of 5mm, 10mm, 16mm for the frequency of 3MHz, obtain the wavelength and near the stomach in order to set the frequency of the transducer array, which was set to the focusing angle of the transducer with three contact surfaces. As a result, the time to reach the set temperature was short days when 3MHz frequency, the focusing angle is titrated is $40^{\circ}$.

Parametric Array Sonar System Based on Maximum Likelihood Detection (최대우도 검파에 기반한 파라메트릭 어레이 소나 시스템)

  • Han, Jeong-Hee;Lee, Chong-Hyun;Paeng, Dong-Guk;Bae, Jin-Ho;Kim, Won-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • In the underwater communications, transmitted acoustic signal is corrupted by interference from multipath. A parametric array transducer is capable of radiating a narrow beam with very low sidelobe levels. In certain cases, the parametric array transducer can help the multipath problem. To improve the performance of the underwater communications, the statistical signal processing methods will be required. In the paper, the communication system using a parametric array transducer was demonstrated. To detect the received signal of the communication system based on the on-off keying, the maximum likelihood method using averaged signal for a particular window size is used. The communication system has GUI using LebVIEW which allows the user to change the parameter. The GUI can also be easily modified based on the characteristics of a parametric array transducer. The implemented system can effectively evaluate the performance of the parametric array transducer.

Design of the broadband pattern of a cymbal transducer array (심벌 트랜스듀서 배열의 광대역 패턴 설계)

  • Kim, Donghyun;Oh, Changmin;Shim, Hayeong;Kang, Soonkwan;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.10-17
    • /
    • 2021
  • The cymbal transducer is a miniaturized version of the Class V flextensional transducer. It has low resonant frequency and high output pressure characteristics compared with its size. However, since it has high quality factor and low energy conversion efficiency as well, it is often used as an array rather than single. When used as an array, a big change in the frequency characteristics occurs in comparison with that of the single transducer due to the interaction between constituent transducers. In this study, we designed a pattern of cymbal array with a view to having broadband characteristics. Three transducers having different center frequencies were designed first. The designed cymbal transducers were used to construct all possible patterns of a 3 × 3 planar array. After analyzing frequency characteristics of these patterns, based on the results, we derived the most effective pattern to achieve a higher fractional bandwidth. The derived array pattern showed an improvement of the fractional bandwidth by 24.9 % in comparison with the reference model.

Development of Split-beam Acoustic Transducer for a 50 kHz Fish Sizing Echo Sounder (50 kHz 체장어군탐지기용 분할 빔 음향 변환기의 개발)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.4
    • /
    • pp.413-422
    • /
    • 2011
  • An improved split-beam transducer for a 50 kHz fish-sizing echo sounder was developed. The main objective of this study was to minimize the side lobe level in the beam pattern and the distance between acoustic centers for adjacent transducer quadrants in the geometrical arrangement of array elements while maintaining a given number of transducer elements and beam width. To achieve these goals, a 32-element planar array transducer ($6{\times}6$ array with one element in each corner missing) was designed using the Dolph-Chebyshev shading function to suppress side lobes in the array beam pattern and fabricated by arranging the inter-element spacing to be substantially equal to half the wavelength using the transducer element of 0.4 times the wavelength in diameter. The performance characteristics of this split-beam transducer were evaluated in the experimental water tank of $5m{\times}5m{\times}6m$ (length${\times}$height${\times}$width). In this study, the design goal of the beam width and side lobe level for transmitting a beam pattern was initially set at $21^{\circ}$ and -30 dB, respectively. However, the measured beam width at 3 dB was $21^{\circ}$ in both directions with side lobe levels of -24.7 dB in the horizontal plane and -25.6 dB in the vertical plane. The averaged beam width at -3 dB of the receiving beam patterns for four receiving quadrants was $31.4^{\circ}$. The transmitting voltage response was 161.5 dB (re $1{\mu}Pa$/V at 1 m) at 50.23 kHz with a bandwidth of 2.16 kHz, and the averaged receiving sensitivity for four receiving quadrants was -178.13 dB (re 1 V/${\mu}Pa$) at 49.8 kHz with a bandwidth of 2.64 kHz.

Optimal design of a concave annular array transducer to generate high intensity focused ultrasound (고강도 집속 초음파 발생용 오목한 환상형 배열 트랜스듀서의 최적설계)

  • Choi, Euna;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.452-465
    • /
    • 2016
  • In this study, the structure of a concave annular array transducer was optimized to generate high intensity focused ultrasound for medical therapeutic application. The transducer has a phased array structure composed of several concentric channels that have 40 mm as the radius of curvature. We derived theoretical equations to analyze the sound field of the transducer and verified the validity of the equations by comparing the results calculated by the equations with those from finite element analyses. We also checked the possibility of dynamic focusing at around the geometric focal point. Further, the level of a grating lobe occurring at an unwanted position in the transducer sound field was confirmed to be reducible through the relation between the number of channels and the frequency of the transducer. Hence, the structure of the transducer was optimized to place the main lobe within a specific range from the zenith while systematically reducing the level of the maximum sidelobe including the grating lobe. The designed structure showed the performance better than that targeted at all the focal points.

Design and Fabrication of a Convex Array Ultrasonic Transducer with Finite Element Analysis (유한요소 해석법을 이용한 컨벡스 배열형 초음파 탐촉자의 설계 및 제작)

  • Lee, Su-Sung;Kwon, Jae-Hwa;Eun, Hong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.592-599
    • /
    • 2002
  • In this study, an ultrasonic transducer was designed with a commercial finite element analysis (FEA) code, PZFlex, and fabricated based on the design. The transducer has the dimension and shape suitable for abdomen diagnosis working at 5 ㎒ and consists of 128 piezoelectric elements disposed in a convex linear array form. The transducer is composed of two impedance matching layers, one backing layer, and kerfs placed between the piezoelectric elements. Validity of the design with the FEA was illustrated through experimental characterization of a sample transducer. Comparison with the design results by equivalent circuit analysis method was also made to check the superiority of the FEA design.