• 제목/요약/키워드: Transdermal Drug Delivery

검색결과 122건 처리시간 0.035초

프로젝션 마이크로광조형 기술을 이용한 생분해성 마이크로구조물 제작 (Fabrication of Biodegradable Microstructures using Projection Microstereolithography Technology)

  • 최재원;하영명;박인백;하창식;이석희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1259-1264
    • /
    • 2007
  • Microstereolithography technology has potential capability for fabrication of 3D microstructures. It evolved from conventional SLA which is one of the RP processes. In a microstereolithography process, 3D microstructures can be easily fabricated by continuously stacking 2D layer which is photopolymerized using a liquid prepolymer. Combination between biocompatible/biodegradable photocurable prepolymer and 3D complex fabrication in microstereolithography makes broad application areas such as medical, pharmaceutic, and bio devices. In particular, a 3D microneedle for transdermal drug delivery and a scaffold for tissue engineering are fabricated using this technology. In this paper, the authors address development of microstereolithography system adapted to large surface and fabrication of various microstructures. In addition, to apply human body we suggest a biodegradable 3D microneedle and a scaffold using biodegradable photocurable prepolymer.

  • PDF

Penetration Enhancement of β2-Selective Agonist, Tulobuterol, Across Hairless Mouse Skin

  • Kim, Byung-Do;Choi, Hoo-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • 제33권2호
    • /
    • pp.79-84
    • /
    • 2003
  • The effects of various pressure sensitive adhesives (PSA) and enhancers on the percutaneous absorption of tulobuterol were investigated. The permeation rate of tulobuterol through hairless mouse skin from various adhesives was evaluated using a flow-through diffusion cell system at $37^{\circ}C$. The permeability of tulobuterol was variable depending on the physicochemical property of the PSA. The permeation rate of tulobuterol from polyethylene oxide grafted acrylic adhesive matrix was higher than that from other PSA matrices. The flux of tulobuterol was $4.37{\pm}0.34\;{\mu}g/hr/cm^2$ from polyethylene oxide grafted acrylic adhesive matrix. When the effects of various enhancers on the percutaneous absorption of tulobuterol from grafted acrylic adhesive were evaluated, Plurol $oleique^{\circledR}$ showed higher flux than all other enhancers tested.

초음속 마이크로 제트 유동에 관한 기초적 연구 (A Fundamental Study of the Supersonic Microjet)

  • 정미선;김현섭;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.622-627
    • /
    • 2001
  • Microjet flows are often encountered in many industrial applications of micro-electro-mechanical systems as well as in medical engineering fields such as a transdermal drug delivery system for needle-free injection of drugs into the skin. The Reynolds numbers of such microjets are usually several orders of magnitude below those of larger-scale jets. The supersonic microjet physics with these low Reynolds numbers are not yet understood to date. Computational modeling and simulation can provide an effective predictive capability for the major features of the supersonic microjets. In the present study, computations using the axisymmetic, compressible, Navier-Stokes equations are applied to understand the supersonic microjet flow physics. The pressure ratio of the microjets is changed to obtain both the under- and over-expanded flows at the exit of the micronozzle. Sonic and supersonic microjets are simulated and compared with some experimental results available. Based on computational results, two microjets are discussed in terms of total pressure, jet decay and supersonic core length.

  • PDF

LC/MS/MS를 이용한 혈장 중 리도카인의 정량 및 리도카인 패치제의 약물동태학적 평가 (LC/MS/MS Method for the Determination of Lidocaine in Hairless Rat Plasma and Pharmacokinetic Applications of Lidocaine Patch)

  • 황지연;김철준;신영희
    • 약학회지
    • /
    • 제56권3호
    • /
    • pp.158-163
    • /
    • 2012
  • Lidocaine has been studied for many chronic pain conditions, including postherpetic neuralgia (PHN) and recently it has also been increasingly used in transdermal drug delivery systems. In this study, pharmacokinetics of a lidocaine patch was studied in four hairless male rats. The plasma concentration was determined by a validated LC/MS/MS method after applying a $3{\times}2cm^2$ (30mg) patch for 12 hours. From the plasma lidocaine concentration vs time curves, $AUC_{0-20h}$, Cmax, and Tmax of lidocaine patch were $2,926.32{\pm}335.28ng{\cdot}h/ml$, $256.86{\pm}29.63ng/ml$, and $6.00{\pm}2.31h$, respectively.

트리암시놀론 겔의 음파영동 경피약물흡수 (Phonophoretic Transdermal Drug Delivery of Triamcinolone acetonide gel)

  • 김태열;김계엽
    • The Journal of Korean Physical Therapy
    • /
    • 제14권2호
    • /
    • pp.219-233
    • /
    • 2002
  • 스테로이드성 소염진통제인 트리암시놀론 겔의 피부투과도를 향상시키기 위하여 초음파를 조사하여 약물의 투과도에 미치는 영향을 비교하였다. 트리암시놀론을 함유한 수용성 겔을 제조하여 물리화학적 시험을 실시하였으며 carbopol을 기제로한 겔이 우수한 제제학적 특성을 보였다. 초음파 조사가 약물의 투과도에 미치는 영향을 알아보기 위하여 hairless mouse의 적출 피부에 대한 in vitro 흡수 실험을 실시하였다. 트리암시놀론 겔 음파영동군이 트리암시놀론겔 단독 처치군에 비하여 투과도가 유의적으로 향상되었다. 특히 주파수가 1MHz인 지속초음파를 고 강도로 적용시 피부투과도의 향상이 더욱 두드러졌다. 따라서 트리암시놀론 겔 도포 후 초음파를 이용한 음파영동 경피흡수가 단독의 겔 처치보다 피부투과에 유용할 것으로 사료된다.

  • PDF

록소프로펜 플라스터의 제제설계 및 평가 (Formulation and Evaluation of Loxoprofen Plasters)

  • 김태성;전인구
    • Biomolecules & Therapeutics
    • /
    • 제9권4호
    • /
    • pp.298-306
    • /
    • 2001
  • To develop a novel transdermal delivery system of loxoprofen (LP), a potent antiinflammatory and analgesic agent, the effects of vehicle composition and drug loading dose on the skin permeation property were investigated. And in vivo skin absorption property studied by analysing the $C_{max}$ and AUC was investigated after applying the developed plaster systems on rabbit back skin. Addition of isopropyl myristate (IPM) and IPM-diethylene glycol monoethyl ether (DGME) cosolvent in the plaster showed higher permeation rates than those from propylene glycol laurate-DGME cosolvent systems. As the concentration of LP in the plaster increased from 0.56 mg/$\textrm{cm}^2$ to 1.19 mg/$\textrm{cm}^2$, the drug release and skin permeation rates increased linearly. At loading dose of 1.19 mg/$\textrm{cm}^2$, the flux reached 35.6 $\mu$g/$\textrm{cm}^2$/hr. New LP plasters showed a good adhesive property onto skin, and showed no crystal formation. The AU $C_{0-24hr}$ and $C_{max}$ after dermal application of LP plaster (60 mg/70 $\textrm{cm}^2$) were found to be 6951$\pm$230 ng.hr/ml and 400$\pm$44 ng/ml, respectively. And the plasma concentration maintained above 300 ng/ml up to 24 hr period. In the carrageenan-induced rat paw edema test, LP plaster showed similar inhibition rate with marketed ketoprofen (Ketoto $p^{R}$) plaster.aster.r.

  • PDF

지황 추출물 첨가 chitosan 기반 기능성 바이오 소재 제조 및 응용 (Preparation and Application of Rehmannia Glutinosa Extract Incorporated Functional Chitosan Based Biomaterials)

  • 이시연;김경중;김윤섭;윤순도
    • 공업화학
    • /
    • 제33권2호
    • /
    • pp.195-201
    • /
    • 2022
  • 본 연구에서는 지황 추출물[Rehmannia glutinosa extract (RE)]이 함유된 chitosan (CH) 기반 바이오 소재를 제조하고, 물리·화학적 특성, RE 방출 특성, 멜라닌 합성 억제 효과, 항산화 효과, elastase 억제 효과를 조사하였다. RE 함유 CH기반 바이오 소재는 casting method와 UV 경화 공정을 통해 제조되었다. 제조된 바이오 소재의 표면 특성은 FE-SEM으로 분석하였고, 물리적 특성은 인장강도, 신축률을 통하여 조사하였다. 경피 약물 전달 시스템을 적용하기 위해 36.5 ℃에서 pH 4.5, pH 5.5, pH 6.5 용액에서와 인공피부를 이용해 제조된 바이오 소재에서 RE의 방출 특성을 조사하였으며, 그 결과, pH 6.5에서 가소제를 첨가하지 않은 바이오 소재와 가소제[glycerol (GL)와 citric acid (CA)]를 첨가하여 제조한 RE 함유 바이오 소재에서 RE의 방출이 pH 4.5에서 보다 약 1.10배 빠르게 일어남을 알 수 있었다. 또한, 인공 피부에서 RE의 방출은 약 6 h 동안 지속적으로 방출됨을 확인하였다. Tyrosinase assay, 2,2-diphenyl-1-picrylhydrazyl(DPPH) assay, elastase assay를 통해 기능성을 평가하였으며, 가소제로 CA를 첨가하고 RE가 함유된 바이오 소재에서 각각 45.12%의 tyrosinase 활성율, 89.40%의 DPPH 라디칼 소거능, 59.94%의 elastase 활성율을 나타내었다.

에토좀 입자크기와 멤브레인 특성 조절을 통한 약물의 경피흡수능 향상 (Enhanced Transdermal Delivery of Drug Compounds Using Scalable and Deformable Ethosomes)

  • 안은정;심종원;최장원;김진웅;박원석;김한곤;박기동;한성식
    • 대한화장품학회지
    • /
    • 제36권2호
    • /
    • pp.105-113
    • /
    • 2010
  • 본 연구에서는 입자 크기 뿐만 아니라 베지클 멤브레인의 변형도를 조절할 수 있는 에토좀을 통해 약물의 경피흡수능을 향상시킬 수 있는 새로운 접근을 소개한다. 이를 위해 신규 육모효능성분인 Triaminodil을 포집한 에토좀을 제조하였고 입자 제조 후 추가적인 에너지를 가함으로써 입자의 크기를 조절하였다. 광산란법, 투과전자현미경, 멤브레인 변형도 측정 등을 통해 입자의 변형도가 입자 크기에 의존하는 것을 확인하였다. 또한 in vitro 피부흡수시험과 전임상 성장기 유도평가를 통해 베지클 멤브레인의 변형도가 Triaminodil의 피부 전달효능에 크게 영향을 미치는 것을 확인하였다. 이러한 결과로부터 담지 된 약물의 전달효능을 극대화 시킬 수 있는 최적 크기의 전달체 영역이 존재함을 확인하였고 이는 입자의 크기와 멤브레인 특성에 큰 영향을 받기 때문에 전달체를 설계하는데 있어 이 두 가지 요인을 고려해야 한다.

가교키토산 매트릭스를 통한 Silver Sulfadiazine의 투과 (Permeability of Silver Sulfadiazine through Crosslinked Chitosan Matrices)

  • 나재운
    • 대한화학회지
    • /
    • 제40권9호
    • /
    • pp.640-648
    • /
    • 1996
  • Chitin을 epichlorohydrin과 반응시켜 가교 chitin을 합성하고, $C_2$ 위치의 아세트아미드기를 탈아세틸화하여 가교 chitosan을 얻었다. 가교 chitosan을 증류수에 팽윤시킨 다음 글리세린과 silver sulfadiazine을 가하여 고분자 matrix를 제조하였다. 이렇게 제조된 matrix로부터 in vitro에서의 약물 방출 pattern을 고찰하기 위해 pH7.4 인산염 완충용액 중에서 약물의 함유량, 글리세린의 농도 변화 및 matrix 두께변화에 미치는 인자들에 관하여 연구 검토 하였다. 고분자 matrix내의 약물의 함유량과 matrix의 두께가 증가할수록 약물 방출 지속 시간은 지연되었다. 그러나 글리세린의 함유량이 증가함에 따라 약물 방출 지속 시간은 오히려 감소 하였다. 또한 약물의 함유량과 글리세린의 함유량이 증가할수록 겉보기 방출속도상수 (K)값도 증가하였으나, matrix 두께가 증가함에 따라서는 겉보기 방출속도상수(K)값이 일정하였다. 이상과 같이 가교 chitosan은 약품의 방출 조절형 제제로서 사용 가능성을 나타냈으며, 약물로 사용된 silver sulfadiazine의 방출거동은 Higuchi model에 따른 확산으로 생각되었다.

  • PDF

Safety Evaluation of Topical Valproate Application

  • Choi, Sun Young;Seop, Song Yi;Hyun, Moo Yeol;Yoo, Kwang Ho;Kim, Beom Joon;Kim, Myeung Nam;Cho, Jae-We
    • Toxicological Research
    • /
    • 제29권2호
    • /
    • pp.87-90
    • /
    • 2013
  • The potential role of topical valproate (VPA) in hair regrowth has been recently suggested. However, safety reports of VPA as a topical formulation are lacking. Therefore, in the present study, we investigated whether VPA causes skin irritation in humans. We first performed a cell viability test and showed that VPA did not exhibit toxicity toward HaCaT keratinocytes, fibroblasts, and RBL-3H mast cells. We then performed clinical patch test and skin irritation test through transdermal drug delivery with the help of microneedle rollers. No significant findings were obtained in the clinical patch test. In the skin irritation test, only 1 patient showed erythema at 1 hr, but the irritation reaction faded away within a few hours. Erythema and edema were not observed at 24 hr. We concluded that VPA has minimal potential to elicit skin irritation. Therefore, we consider that VPA can safely be applied to human skin.