• 제목/요약/키워드: Trans-tibial prostheses

검색결과 4건 처리시간 0.016초

Pressure Distribution in Stump/Socket Interface in Response to Socket Flexion Angle Changes in Trans-Tibial Prostheses With Silicone Liner

  • Kang, Pil;Kim, Jang-Hwan;Roh, Jung-Suk
    • 한국전문물리치료학회지
    • /
    • 제13권4호
    • /
    • pp.71-78
    • /
    • 2006
  • This study examined the effects of socket flexion angle in trans-tibial prosthesis on stump/socket interface pressure. Ten trans-tibial amputees voluntarily participated in this study. F-socket system was used to measure static and dynamic pressure in stump/socket interface. The pressure was measured at anterior area (proximal, middle, and distal) and posterior area (proximal, middle, and distal) in different socket flexion angles ($5^{\circ}$, $0^{\circ}$, and $10^{\circ}$). Paired t-test was used to compare pressure differences in conventional socket flexion angle of $5^{\circ}$ with pressures in socket flexion angles of $0^{\circ}$ and $10^{\circ}$ (${\alpha}$=.05). Mean pressure during standing in socket flexion angle of $10^{\circ}$ decreased significantly in anterior middle area (19.7%), posterior proximal area (10.4%), and posterior distal area (16.3%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (19.3%) and decreased significantly in anterior distal area (19.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (19.6%) and increased significantly in anterior distal area (8.2%) compared with socket flexion angle of $5^{\circ}$. Peak pressure during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.0%) compared with socket flexion angle of $5^{\circ}$ and peak pressure during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (22.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure over 80% of peak pressure ($MP_{80+}$) during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.9%) and decreased significantly in anterior distal area (22.5%) compared with socket flexion angle of $5^{\circ}$. $MP_{80+}$ during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior distal area (34.1%) compared with socket flexion angle of $5^{\circ}$. Asymmetrical pressure change patterns in socket flexion angle of $0^{\circ}$ and $10^{\circ}$ were revealed in anterior proximal and distal region compared with socket flexion angle of $5^{\circ}$. To provide comfortable and safe socket for trans-tibial amputee, socket flexion angle must be considered.

  • PDF

편측대퇴의지와 편측하퇴의지의 보행특성 비교 (Comparisons of the gait characteristics depended on Unilateral Trans-Femoral or Trans-Tibial Prostheses)

  • 안창식;정석
    • The Journal of Korean Physical Therapy
    • /
    • 제16권2호
    • /
    • pp.108-115
    • /
    • 2004
  • The aim of this study is to present the basic reference data of age and specipic gait parameters for comparisons of the gait characteristics depended on Unilateral Trans-Femoral or Trans-Tibial Prostheses. The basic gait parameters were extracted from 10 Adult, 10 above knee(A/K) patients and 10 below knee(B/K) patients, 50 to 60 years of age using VICON 512 Motion Analyzer. The results were as follows; 1) The mean Cadence of the above knee(A/K) patients and below knee(B/K) patients were $87.77{\pm}8.64$ steps/min, to $99.84{\pm}11.14$ steps/min.(p<0.05) 2) The mean Walking Speed of the above knee(A/K) patients and below knee(B/K) patients were $0.84{\pm}0.15$ m/s, to $0.96{\pm}0.25$ m/s.(p>0.05) 3) The mean Stride Length of the above knee(A/K) patients and below knee(B/K) patients were $1.14{\pm}0.14$ m, to $1.14{\pm}0.22$m.(p>0.05) 4) The mean maximal angles of joint on the hip flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $34.75{\pm}10.18_{\circ}$, to $32.32{\pm}6.34_{\circ}$ .(p>0.05) 5) The mean maximal angles of joint on the knee flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $66.97{\pm}15.08_{\circ}$, to $52.65{\pm}9.21_{\circ}$ .(p<0.05) 6) The mean maximal angles of joint on the ankle dorsiflexion motion for different above knee(A/K) patients and below knee(B/K) patients were $14.41{\pm}4.82_{\circ}$, to $10.04{\pm}3.49_{\circ}$ .(p>0.05) 7) The mean maximal angles of joint on the ankle plantarflexion motion for different above knee(A/K) patients and below knee(B/K) patients were $5.77{\pm}3.17_{\circ}$, to $2.75{\pm}4.49_{\circ}$ .(p>0.05)

  • PDF

편측하퇴의지의 절단 길이에 따른 보행 특성 비교 (Comparisons of the gait characteristics depended on amputation length of the Unilateral Trans-Tibial Prostheses)

  • 유재응;정석
    • The Journal of Korean Physical Therapy
    • /
    • 제15권3호
    • /
    • pp.166-172
    • /
    • 2003
  • The aim of this study is to present the basic reference data of age and specific gait parameters for comparisons of the gait characteristics depended on amputation length of the Unilateral Trans-Tibial Prostheses. The basic gait parameters were extracted from 10 Adult, and 20 below knee(B/K) patients, 50 to 60 years of age using VICON 512 Motion Analyzer. The results were as follows; 1. The mean Cadence of the above knee(A/K) patients and below knee(B/K) patients were $87.77{\pm}8.64$ steps/min, to $99.84{\pm}11.14$ steps/min.(p<0.05) 2. The mean Walking Speed of the above knee(A/K) patients and below knee(B/K) patients were $0.84{\pm}0.15$ m/s, to $0.96{\pm}0.25$ m/s.(p>0.05) 3. The mean Stride Length of the above knee(A/K) patients and below knee(B/K) patients were $1.14{\pm}0.14\;m$, to $1.14{\pm}0.22m$.(p>0.05) 4. The mean maximal angles of joint on the hip flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $34.75{\pm}10.18_{\circ}$, to $32.32{\pm}6.34_{\circ}$.(p>0.05) 5. The mean maximal angles of joint on the knee flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $66.97{\pm}15.08_{\circ}$, to $52.65{\pm}9.21_{\circ}$. (p<0.05) 6. The mean maximal angles of joint on the ankle dorsi-flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $14.41{\pm}4.82_{\circ}$, to $10.04{\pm}3.49_{\circ}$.(p>0.05) 7. The mean maximal angles of joint on the ankle plantar-flexion motion for different above knee(A/K) patients and below knee(B/K) patients were $5.77{\pm}3.17_{\circ}$, to $2.75{\pm}4.49_{\circ}$.(p>0.05)

  • PDF

힘측정판과 레이저 광을 이용한 정적 의족정렬장치의 개발 (Development of a Static Prosthesis-Alignment Device Using a Force Plate and a Laser Light)

  • 이기원;김기완;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.385-390
    • /
    • 2000
  • 의족착용자의 보행에 있어서 의족의 정렬은 매우 중요하나, 정량적이고 다양한 의족에 공통적으로 적용할 수 있는 정렬방법이 아직 소개되지 않고 있다. 본 연구를 통해서 load cell, 레이저, 이송 가이드로 구성되는 정적 의족정렬시스템을 개발되었다. 개발된 시스템을 24명의 남자성인과 4명의 하퇴의족착용자에게 적용하여 직립자세와 전방, 후방ㅇ로 기운 자세에서 족관절, 슬관절, 대전자, 어깨관절등과 하중선과의 상대적 위치를 측정하였다. 정상인의 중립자세에서 하중선의 위치는 외과, 슬관절, 견관절에서는 앞쪽에 그러나 대전자에서는 뒤쪽에 있었다. 정상인이 앞쪽으로 최대한 기운 자세에서 외과와 슬관절, 대전자는 하중선의 뒤쪽에 위치하였으나 견관절은 앞쪽에 위치하였다. 그러나 뒤쪽으로 기운 자세의 경우, 하중선은 견관절을 제외한 모든 곳의 뒤쪽에 위치하였다. 의족착용자의 환측의 하중선은 족관절, 슬관절, 대전자, 견관절 모두의 전방에 위치하였으며, 의족착용자의 건측에서의 하중선의 위치는 정상인의 경우와 통계적으로 유사하였다. 본 연구를 통해서 개발된 정적 의족정렬시스템은 의족 착용자는 물론, 정상인들의 하중선과 주요 관절과의 상대적 위치를 파악하는데 매우 유용하게 사용될 수 있을 것으로 기대된다.

  • PDF