• 제목/요약/키워드: Train Station

검색결과 379건 처리시간 0.031초

KTX 열차 운전 모드에 따른 정차소음 특성 (Characteristics of Braking Noise in accordance with Operating Mode of KTX High Speed Vehicle)

  • 이찬우;김재철;조준호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.816-822
    • /
    • 2005
  • High speed trains with maximum speed of 300km/h, named KTX, have started revenue services since April 2004. Is becoming big problem where currently the KTX train because excessive braking noise at a station platform. The KTX braking noise follows in operating mode of KTX train and important railroad station where the quality appears different, the quality against hereupon from the commerce vehicle from the research which it sees it executes and comparison to analyze.

  • PDF

영상처리를 이용한 철도 승강장 영역에서의 열차상태 검지방법 (Train detection in railway platform area using image processing technology)

  • 오세찬;윤용기;백종현;조현정
    • 한국산학기술학회논문지
    • /
    • 제13권12호
    • /
    • pp.6098-6104
    • /
    • 2012
  • 현재 철도 역사의 승객 위험영역과 보안영역 등의 감시를 위해 수십대의 CCTV를 널리 이용하고 있다. 그중에서 가장 빈번한 사고가 발생되는 곳은 승객의 열차 승하차가 이루어지는 승강장 영역이다. 하지만 사고 예방과 신속한 대응을 위해 역무원이 여러 대의 CCTV를 항시 모니터링 하기는 불가능하다. 따라서 위험상황을 자동으로 인지할 수 있는 영상처리 기술을 이용한 승강장 모니터링 시스템이 요구되며, 이를 위해서는 우선적으로 승강장에서의 정확한 열차상태 판단이 필요하다. 본 논문은 비전기반 승강장 모니터링 시스템을 위한 승강장에서의 열차상태에 대한 검지방법을 제안한다. 제안된 검지 방법은 승강장에서의 열차 점유영역을 분석하여 열차의 진입(IN), 진출(OUT), 정지(ON), 없음(OFF)의 4가지 생태를 판별한다. 제안된 검지방법의 성능 평가을 위해 서울메트로 4호선 동작역과 남태령역을 대상으로 열차상태 검지결과를 제시하였다.

무절연 가청주파수(AF) 궤도회로장치에 관한 고찰 (Technical Consideration of Non-Insulated Audio Frequency Track-Circuit Device)

  • 조봉관;김종기;황현철;류상환;강신주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1709-1715
    • /
    • 2011
  • A track-circuit device exploits two rails as a conductor of an electrical circuit. It detects the presence or absence of the trains with variation of received level when wheel sets of the train shunt rails together. So, it plays an important role in train operation. Non-insulated audio frequency(AF) track-circuit device can separate the rails into tracks by insulated joints without physically cutting the rails. And it transmits AF signals at track boundary, of which frequency is different between adjacent tracks. It has been employed at station-to-station section of domestic high speed rail, general rail, and subway. But It was not used at station yard of complicated general railway where lots of branches exist. In this paper, we consider current development status of non-insulated AF track-circuit device for the use of station yard.

  • PDF

터널내의 흡음재 부착 효과 연구 (A Study for the Effect of Sound Absorbing Materials in the Tunnel)

  • Park, Han-Lim;Lee, Duck-Joo
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.750-750
    • /
    • 2001
  • Todays, according to development of traffics, there are so many tunnels around us. Tunnels are used for trains, subway trains, cars, etc. Especially for subway, all of its routes are tunnels. So the noise of the subway train cannot radiated out of the station and the noise level in the station and train cabin is so high. There are some methods to reduce this noise and one of them is using absorbing materials. But the area of the tunnel and station is very large, so it is important to determine the effective position and amount of absorbing materials before attaching them. In this study, we studied the effect of sound absorbing materials in the tunnel using boundary element method. We applied BEM for general boundary conditions. With BEM calculations, we found the effect of absorbing materials and effective positions for the subway tunnel and station.

  • PDF

자율분산 역제어시스템의 효율성을 위한 자료분석 및 자료 활용방법에 관한 연구 (A study on material analysis and the usage for efficiency of the Autonomus Station Control System)

  • 하승태;안진;용성완
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.636-641
    • /
    • 2008
  • In this paper, the analysis methods of available information are reviewed and it is elicited to the method of which the analysis results are applied to the Autonomous Decentralized Train Management System for the optimization at the point of the route control time and for making the efficiency shunting plan in the Autonomous Centralized Station Operation Control System. As the statistics and estimated information which are got through the utilizable information analysis are applied for the automatic route control function and the shunting plan management of the station operation control system, it is possible to use efficiently the station information by the autonomous route control system. And as the exact forecast information needed for the shunting plan establishment and the operation is provided to the operator, it is established to the efficient train operation plan.

  • PDF

지하철 터널내 열차풍 예측 프로그램 개발에 관한 연구 (A Study on the Development of the Train Wind Rate Prediction Program in Tunnel of the Subway)

  • 김종열;최광환
    • 동력기계공학회지
    • /
    • 제3권1호
    • /
    • pp.38-44
    • /
    • 1999
  • Subway is one of the most important transportation and its facilities are increased by the drift of population to cities in these days. But heat generation results from lighting, human and traffic increase in subway, half-closed space, gives uncomfortable sense to the subway passengers. Therefore, natural ventilation by piston effect is done to relieve uncomfortable sense. But train wind by piston effect gives uncomfortable sense to the subway passengers, too. So the numerical calculation of inflow and outflow amounts is important to predict thermal environment and reduce train wind. In case of actual survey of train wind in target station, the amount of train wind are about $3100m^3/train$ at the minimum, about $6000m^3/train$ at the maximum, about $4200m^3/train$ on average. When comparison between simulation for train wind prediction and actual survey for accuracy was done train wind prediction program showed similar results.

  • PDF

대전북(대전 조차장-대전역) 고속전철 연계 운행 구간의 운전시격 분석 (Headway Analysis in Daejeon Nord section(Daejeon shunting yard-Daejeon station) which high speed train and conventional trains will be run)

  • 김용규;김종기;유창근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.810-813
    • /
    • 2003
  • The present headway on KNR(Korea National Railway) lines varies from 6 to 10 minutes depending on the each line and by the operation of High Speed line in 2004, the bottleneck would be expected within a few sections such as Daejeon-Daejeon shunting yard which will be the common mute between KTX(Korea Train Express) and conventional trains. Therefore, KNR would like to reduce the headway of the all lines by 4 minutes with the implementation of ERTMS/ETCS on-board system. Where ETCS(European Train Control system), the subsystem of ERTMS, is Automatic Train Protection system for safety train running. This study will be analyze expected braking distance and running time depending on characteristics of conventional passenger and freight trains and high speed train will be operated within electrified conventional line for comparing the headways of ATS(Automatic Train Stop) system and ETRMS/ETCS system within the Daejeon-Daejeon shunting yard section.

  • PDF

화재열차의 역사 접근 시 PSD가 설치된 역사 제연을 위한 환기장치 운전 비정상상태 해석 (A transient CFD simulation of ventilation system operation for smoke control in a subway station equipped with a Platform Screen Door(PSD) when a train under fire is approaching the station)

  • 신규호;허남건;원찬식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.269-272
    • /
    • 2006
  • The heat and smoke which generated by subway under fire is one of the most harmful factor in air tighten underground station. To prevent this, Trackway Exhaust System(TES) can be used. The heat released from the train running in the tunnel raises the temperature at the platform and the trackway, and thus proper ventilation system is required for comfortable underground environment. When the fire is occurred, TES is operated as smoke exhaust mode from normal ventilation mode. In the present study, the subway station which is one of the line number 9 in Seoul subway is modeled, and fired situation is simulated with several ventilation mode of ventilation system in trackway. For this simulation whole station is modeled. Non steady state 3D simulation which considered train under fire is entering to the station is performed. Temperature and smoke distribution in platform and trackway are compared. To represent heat by fire, heat flux was given to the fired carriage, also to describe smoke by fire, concentration of CO is represented. As the result of present study, temperature and smoke distribution is different as the method of ventilation in trackway and platform is changed. In over side of trackway, the fan must be operated as exhaust mode for efficient elimination of heat and smoke, and supply mode of fan operation in under side shows better distribution of heat and smoke. The ventilation system which is changed from ventilation mode to exhaust mode can be applied to control heat and smoke under fire.

  • PDF

화재열차가 진입하여 정차하는 지하철 역사에서 제연을 위한 환기장치 운전에 대한 수치해석 연구 (A Numerical Study of Ventilation System Operation for Smoke Control in a Subway Station when a Train under Fire is Approaching)

  • 이승호;허남건;차철현;류홍선;김동현;장용준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.136-141
    • /
    • 2009
  • The platform screen door(PSD) is installed in the station of the Seoul Metro 9th line for passengers' safety and comfortable environment of the station. The track way exhaust system(TES) is also operated with PSD to exhaust heat released from train. TES can also be used for the purpose of the heat and smoke control in an emergency case of the carriage fire. When the fire is occurred, operation of TES is switched to the smoke exhaust mode form its normal ventilation mode. In the present study, a subway station of Seoul Metro 9th line is modeled, and a 3-D CFD simulation is performed to investigate effectiveness of designed TES in case of fire. A scenario that a train under fire is arriving the station is simulated for several possible operation modes of the TES using moving mesh technique. As a result, temperature and CO concentration distribution in the station is obtained for each operation modes of TES. The effectiveness of TES operation in case of fire is also discussed.

  • PDF

시계열모형을 활용한 춘천시 강촌역 단기수송수요 예측 (Forecasting short-term transportation demand at Gangchon Station in Chuncheon-si using time series model)

  • 전창영;유가기;양희원
    • 아태비즈니스연구
    • /
    • 제14권4호
    • /
    • pp.343-356
    • /
    • 2023
  • Purpose - This study attempted to predict short-term transportation demand using trains and getting off at Gangchon Station. Through this, we present numerical data necessary for future tourist inflow policies in the Gangchon area of Chuncheon and present related implications. Design/methodology/approach - This study collected and analyzed transportation demand data from Gangchon Station using the Gyeongchun Line and ITX-Cheongchun Train from January 2014 to August 2023. Winters exponential smoothing model and ARIMA model were used to reflect the trend and seasonality of the raw data. Findings - First, transportation demand using trains to get off at Gangchon Station in Chuncheon City is expected to show a continuous increase from 2020 until the forecast period is 2024. Second, the number of passengers getting off at Gangchon Station was found to be highest in May and October. Research implications or Originality - As transportation networks are improving nationwide and people's leisure culture is changing, the number of tourists visiting the Gangchon area in Chuncheon City is continuously decreasing. Therefore, in this study, a time series model was used to predict short-term transportation demand alighting at Gangchon Station. In order to calculate more accurate forecasts, we compared models to find an appropriate model and presented forecasts.