• Title/Summary/Keyword: Track detector

Search Result 98, Processing Time 0.022 seconds

Preliminary Study on Applicability of Accumulate Personal Neutron Dosimeter for Cosmic-ray Exposure of Aviators (운항승무원의 우주방사선 피폭 평가에 있어 누적형 개인 중성자 선량계의 적용가능성 예비 연구)

  • Kim, Hyeong-Jin;Chang, Byung-Uck;Byun, Jong-In;Song, Myeong Han;Kim, Jung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.44-51
    • /
    • 2013
  • ICRP recommended that cosmic ray exposure to the pilot and cabin crew would be considered as an occupational exposure due to their relatively high exposure. Since 2012 with the Act No. 10908 (Natural radiation management), the guideline of cosmic ray exposure to the pilot was established in Korea. The applicability of the solid-state nuclear track detector for personal dose assessment of pilot and cabin crew was evaluated. Dose linearity and angle dependence of dosimeters to the neutron were evaluated by $^{252}Cf$ neutron emitting source. The track density has a good agreement with the dose ($r^2$=0.99) and highly dependent on the degree of an angular of the dosimeter to the neutron source. In addition, the dosimeters (SSNTD) were exposed to cosmic ray in an aircraft during its cruising for more than two months in collaboration with Airline Pilots Association of Korea. Although the correlation between the track density from aircraft cruising altitude and expected neutron dose is low, however RSNS dosimeter could be used for personal neutron dosimeter. For application of RSNS as a personal dosimeter for pilot and cabin crew, additional studies are required.

A Study on the Concentrations of Indoor Radon for Houses in Chungcheongbuk-do Province, Korea (충청북도 일부지역 내 주택 실내 라돈 농도)

  • Ji, Hyun-A;Yoo, Ju-Hee;Kim, Ga-Hyun;Won, Soo Ran;Kim, Seonhong;Lee, Jeongsub
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.668-674
    • /
    • 2019
  • Objectives: Modern people spend most of their day indoors. As the health impact of radon becomes an issue, public interest also has been growing. The primary route of potential human exposure to radon is inhalation. Long-term exposure to high levels of radon increases the risk of developing lung cancer. Radon exposure is known to be the second-leading cause of lung cancer, following tobacco smoke. This study measures the indoor radon concentrations in detached houses in area A of Chungcheongbuk-do Province considering the construction year, cracks in the houses, the location of installed detectors, and seasonal effects. Methods: The survey was conducted from September 2017 to April 2018 on 1,872 private households located in selected areas in northern Chungcheongbuk-do Province to figure out the year of building construction and the location of detector installed and identify the factors which affect radon concentrations in the air within the building. Radon was measured using a manual alpha track detector (Raduet, Hungary) with a sampling period of longer than 90 days. Results: Indoor radon concentrations in winter within area A was surveyed to be 168.3±193.3 Bq/㎥. There was more than a 2.3 times difference between buildings built before 1979 and those built after 2010. The concentration reached 195.4±221.9 Bq/㎥ for buildings with fractures and 167.2±192.4 Bq/㎥ for buildings without fractures. It was found that detectors installed in household areas with windows exhibited a lower concentration than those installed in concealed spaces. Conclusion: High concentrations of indoor radon were shown when there was a crack in the house. Also, ventilation seems to significantly affect radon concentrations because when the location of the detector in the installed site was near windows compared to an enclosed area, radon concentration variation increased. Therefore, it is considered that radon concentration is lower in summer because natural ventilation occurs more often than in winter.

Determination of Uranium Concentration in Solid- and Liquid-state Geological Materials by Fission Track Registration Technique and its Applicability (피션트랙 검출기법에 의한 고체 및 액체상태 지질물질의 우라늄 정량과 그 적용성)

  • Shin, Seong-Cheon
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.77-90
    • /
    • 2015
  • The fission track registration techniques for accurate determinations of uranium in solid- and liquid-state geological materials were recommended and their applicability were examined. The determination of uranium can be achieved by optical counting of neutron-induced fission tracks of $^{235}U$ registered on solid-state track detectors under high magnification. In a dry registration method using powdered pellets of rocks (e.g., granite and coal) showing good uranium-affinity, it was not easy to decide an overall mean concentration over the total sample owing to track-clusters caused by frequent presence of uranium-bearing minerals. Separate scanning for homogeneous and track-clustered parts may be an alternative choice. Assuring the homogeneity over the whole sample, high reproducibilities were confirmed both from duplicate detections using mica and Lexan polycarbonate detectors and from multiple measurements at different thermal neutron fluences. The wet registration method using sealed quartz tubes is recommended to overcome the common heterogeneity in uranium concentrations of $10^1ppm$ and more. Adopting the wet registration, the uranium homogeneity was recovered below the $10^0ppm$ level and the lower detection limit was proved to reach without difficulty the $10^2ppb$ (i.e. $ng\;g^{-1}$) level.

A study on the Prediction of Indoor Concentration due to Radon Exhalation from Domestic Building Materials (건축자재 라돈 방출에 의한 실내공기 중 라돈농도 예측에 관한 연구)

  • Lee, Cheolmin;Gwak, Yoonkyung;Lee, Donghyun;Lee, Dajeong;Cho, Yongseok
    • Journal of Environmental Science International
    • /
    • v.24 no.9
    • /
    • pp.1131-1138
    • /
    • 2015
  • Radon exhalation rates have been determined for samples of concrete, gypsum board, marble, and tile among building materials that are used in domestic construction environment. Radon emanation was measured using the closed chamber method based on CR-39 nuclear track detectors. The radon concentrations in apartments of 100 households in Seoul, Busan and Gyeonggi Provinces were measured to verify the prediction model of indoor radon concentration. The results obtained by the four samples showed the largest radon exhalation rate of $0.34314Bq/m^2{\cdot}h$ for sample concrete. The radon concentration contribution to indoor radon in the house due to exhalation from the concrete was $31.006{\pm}7.529Bq/m^3$. The difference between the prediction concentration and actual measured concentration was believed to be due to the uncertainty resulting from the model implementation.

Calibration of CR-39 for Measurement of Radon in Air (공기중의 라돈 농도 측정을 위한 CR-39의 교정)

  • Park, Y.W.;Chang, S.Y.;Ha, C.W.;Ro, S.G.
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.18-22
    • /
    • 1989
  • In order to calibrate the CR-39 Solid State Nuclear Track Detector (SSNTD), a closed -circulation type SSNTD-Calibration-System containing a radon-cup with the Millipore filter has been set-up, and the tracks produced on the SSNTD were measured for the known amount of radon concentration. Calibration factor for the time integrated radon concentration as a function of the track density on CR-39 was estimated to be $0.24{\pm}0.09(pCi/l)\;day/(Tr/cm^2)$.

  • PDF

On the Etching Condition of Cellulose Nitrate Solid State Nuclear Track Detector (SSNTD) (Cellulose Nitrate 고체비적검출기(固體飛跡檢出器)의 부식조건(腐蝕條件))

  • Myung, Dong-Bum;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.26-33
    • /
    • 1987
  • An experimental study for an optimum etching of commercialized cellulose nitrate SSNTD, CA 80-15 and LR 115-1 for detecting alpha particles, was carried out. Alt-hough ordinary etching condition of the detectors has been recommended by the producer, a remarkable discrepancy in etching tine was found. The detectors were irradiated with a $0.1{\mu}Ci\;^{241}Am$ alpha source under a known geometrical arrangement. Analysis on the track size as functions of etching time and etchant concentration and comparative examination of theoretically predicted number of tracks per unit area with that recorded on the detectors were made, including a study on the variation of detection efficiency with the effective energy of the incident alpha particles.

  • PDF

Determination of the Uranium Backgrounds in Lexan Films for Single Particle Analysis using FT-TIMS technique

  • Park, Su-Jin;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • v.2 no.2
    • /
    • pp.57-60
    • /
    • 2011
  • As background significantly affects measurement accuracy and a detection limit in determination of the trace amounts of uranium, it is necessary to determine the impurities in the Lexan detector film for single particle measurements by thermal ionization mass spectrometry coupled with fission track technique (FT-TIMS). We have prepared various micro sizes of the blank Lexan detector film using a micromanipulation technique for uranium measurements by TIMS. Few tens of fg of uranium background with no remarkable dependency on the film sizes were observed in the blank Lexan films with the sizes from $50{\times}50\;{\mu}m^2$ to $300{\times}300\;{\mu}m^2$. Based on the determination of the uranium background in the Lexan film, any background correction is necessary in the isotopic analysis of a uranium single particle with micron sizes when the particle bearing Lexan film is dissected with less than $300{\times}300\;{\mu}m^2$ size. The isotopic analysis of a uranium particle in U030 standard material using TIMS was carried out to verify the applicability of the Lexan film to the single particle analysis with high accuracy and precision.

A Robust Face Tracking System using Effective Detector and Kalman Filter (효과적인 검출기와 칼만 필터를 이용한 강인한 얼굴 추적 시스템)

  • Seong, Chi-Young;Kang, Byoung-Doo;Jeon, Jae-Deok;Kim, Sang-Kyoon;Kim, Jong-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.1
    • /
    • pp.26-35
    • /
    • 2007
  • We present a robust face tracking system from the sequence of video images based on effective detector and Kalman filter. To construct the effective face detector, we extract the face features using the five types of simple Haar-like features. Extracted features are reinterpreted using Principal Component Analysis (PCA), and interpreted principal components are used for Support Vector Machine (SVM) that classifies the faces and non-faces. We trace the moving face with Kalman filter, which uses the static information of the detected faces and the dynamic information of changes between previous and current frames. To make a real-time tracking system, we reduce processing time by adjusting the frequency of face detection. In this experiment, the proposed system showed an average tracking rate of 95.5% and processed at 15 frames per second. This means the system is robust enough to track faces in real-time.

  • PDF

MTF measuring method of TDI camera electronics

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon;Choi, Hae-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.540-543
    • /
    • 2007
  • The modulation transfer function (MTF) in a camera system is a measurement of how well the system will faithfully reproduce the original scene. The electro-optical camera system consists of optics, an array of pixels, and an electronics which is related to the image signal chain. The system MTF can be cascaded with each element's MTF in the frequency domain. That is to say, the electronics MTF including the detector MTF can be recalculated easily by the acquired system MTF if the well-known test optics is used in the measuring process. A Time-Delay and Integration (TDI) detector can make a signal increase by taking multiple exposures of the same object and adding them. It can be considered the various methods to measure the MTF of the TDI camera system. This paper shows the actual and practical MTF measuring methods for the detector and electronics in the TDI camera. The several methods are described according to the scan direction as well as the TDI stages such as the single line mode and the multiple-lines mode. The measuring is performed in the in the static condition or dynamic condition to get the point spread function (PSF) or the line spread function (LSF). Especially, the dynamic test bench is used to simulate on track velocity to synchronize with TDI read out frequency for the dynamic movement.

  • PDF

A Study on Adaptive Linear MMSE Detector for DS-CDMA Reverse Link in Rayleigh Fading Environment (레일리 페이딩 환경하에서 DS-CDMA 역방향 링크에 적용 가능한 적응 선형 MMSE 수신기의 연구)

  • 안태기;이병섭;김성락;이정구
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.2
    • /
    • pp.131-140
    • /
    • 1998
  • MAI(Multi-Access Interference) and fast channel variation due to the fading environment are the major problems in the mobile CDMA communication systems. Recently, interest has been increasing in applying the Adaptive Linear MMSE Detector to MAI cancellation in the CDMA reverse link. In this paper, we propose a modified Adaptive Linear MMSE Detector structure which can be used in Long-duration code CDMA system in the presence of independent Rayleigh fading. We use independent multiple tap-weight vector structure to cope with the variation of spreading sequence pattern between neighbor symbols because of the Long-duration code. In this case, more exact channel parameter estimation is required. To solve this problem, we use coherent CDMA structure which can track the channel parameters like amplitude and phase by employing the low power pilot channel in the CDMA reverse link.

  • PDF