• Title/Summary/Keyword: Trace metal ions

Search Result 76, Processing Time 0.021 seconds

Studies on the Separation and Preconcentration of Metal Ions by Chelating Resin containing (Polystyrene-divinylbenzene)-thiazolylazo phenol Derivatives(II) ((Polystyrene-divinylbenzene)-thiazolylazo phenol형 킬레이트 수지에 의한 금속이온의 분리 및 농축에 관한 연구(II))

  • Lim, Jae-Hee;Seol, Kyung-Mi;An, Hye-Sook;Chung, Koo-Chun;Lee, Chang-Heon;Lee, Won
    • Analytical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.364-372
    • /
    • 1996
  • The sorption and desorption properties of U(VI), Th(IV), Zr(IV), Cu(II), Pb(II), Ni(II), Zn(II), Cd(II) and Mn(II) ions on XAD-16-[2-(2-thiazolylazo)-p-cresol](TAC) chelating resin were studied by elution method for selective separation, concentration and recovery of trace metal ions in sea water. The optimum conditions for the sorption of metal ions were examined with respect to flow rate, pH and concentration of buffer solution. The overall capacities of some metal ions on this chelating resin were 0.41mmol U(VI)/g resin, 0.55mmol Th(IV)/g resin, 0.43mmol Cu(II)/g resin, and 0.32mmol Zr(IV)/g resin, respectively. The elution order of metal ions obtained from breakthrough capacity and overall capacity at pH 5.0 was found as Th(IV)>Cu(II)>U(VI)>Zr(IV)>Pb(II)>Ni(II)>Zn(II)>Cd(II)>Mn(II). Desorption of characteristics for metal ions were investigated with desorption agents such as $HNO_3$, HCl, $HClO_4$, $H_2SO_4$, and $Na_2CO_3$. It was found that most of metal ions except Zr(IV) showed high desorption efficiency with 2M $HNO_3$. But, desorption and recovery of Zr(IV) ion were successfully performed with 1M $H_2SO_4$. The resin was applied for separation and preconcentration of trace amount of U(VI) ion from artificial sea water and the recovery of U(IV) was over 96%.

  • PDF

Epoxidation of Olefins by Iodosylbenzene Catalyzed by Non-Porphyrin Metal Complexes

  • Nam Wonwoo;Baek Seung Joong;Kazuko I. Liao;Joan Selverstone Valentine
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1112-1118
    • /
    • 1994
  • Epoxidation of olefins has been studied using iodosylbenzene (PhIO) as the terminal oxidant and binuclear and mononuclear complexes of $Mn^{2+}$, $Co^{2+}$, and $Cu^{2+}$ as catalysts. Epoxides were the predominant products with trace amounts of allylic oxidation products, and the metal complexes were found to be effective catalysts in the epoxidation reactions. The reactivity of binuclear copper complexes was greater than that of the mononuclear copper complexes, whereas the binuclear and mononuclear complexes of $Mn^{2+}$ and $Co^{2+}$ showed similar reactivities. The nature of the ligands bound to copper did not influence the reactivity of the binuclear copper complexes so long as copper ions were held in close proximity. A metal-iodosylbenzene complex, such as suggested previously for Lewis acidic metal complex-catalyzed epoxidation by iodosylbenzene, is proposed as the active epoxidizing species. Some mechanistic aspects are discussed as well.

Chemistry of Carbonate-Sulfur Flux

  • Q. Won Choi;Choi Han;Chang So-Young;Pyun Chong-Hong;Kim Chang-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1118-1121
    • /
    • 1994
  • Reactions of alkaline metal carbonates with sulfur are investigated in detail. The evolution of CO and a trace of $SO_2$ were observed in the course of reaction with major component of polysulfides. Some evidences that the reaction proceeds with breaking of terminal sulfur-sulfur bond in the sulfur polymer, and forming CO, $SO_2$ and polysulfide are presented. Polysulfides have the role of keeping free sulfur and allow it to react with other chemicals to rather high temperatures.plexes, whereas the binuclear and mononuclear complexes of Mn$^{2+}$ and Co$^{2+}$

Online preconcentration and preelutioin for the ion chromatographic determination of trace anions in high-sulfate wastewater

  • Song, Kyung-Sun;Kim, Sang-Yeon;Cheong, Young-Wook
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2005.05a
    • /
    • pp.327-328
    • /
    • 2005
  • Trace anions in high-sulfate wastewater from mainly derelict mines were determined by ion chromatography with on-line preconcentration and preelution technique. As the sample was preconcentrated and more strongly held ions were preeluted to the principal separation system, this approach was highly effective in removing large concentration of sulfate in high-sulfate wastewater. With this practical on-line preelution treatment, the peaks of fluoride and chloride showed good resolution even when the sulfate concentration was as high as 2000 mg/L and the analyzed total metal concentration was above 500 mg/L.

  • PDF

Extraction Equilibria and Solvent Sublation for Determination of Ultra Trace Bi(Ⅲ), In(Ⅲ) and TI(Ⅲ) in Water Samples by Ion-Pairs of Metal-2-Naphthoate Complexes and Tetrabutylammonium Ion

  • Kim, Young-Sang;Choi, Yoon-seok;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1381-1391
    • /
    • 2002
  • The solvent sublation using ion pairs of metal-2-naphthoate(2-HNph) and tetrabutyl ammonium ($TBA^+$) ion has been studied for the concentration and determination of ultra trace Bi(III), In(III) and Tl(Ⅲ) ions in water samples. The partition coefficients ($K_p$) and the extraction percentages of 2-HNph and the ion pairs to methyl isobutyl ketone (MIBK) were obtained as basic data. After the ion pair $TBA^+$·M$(Nph)_4^-$ was formed in water samples, the analytes were concentrated by the solvent sublation and the elements were determined by GF-AAS. The pH of the sample solution, the amount of the ligand and counter ion added and stirring time were optimized for the efficient formation of the ion pair. The type and amount of optimum surfactant, bubbling time with nitrogen and the type of solvent were investigated for the solvent sublation as well. 10.0 mL of 0.1 M 2-HNph and 2.0 mL of 0.1 M $TBA^+$ were added to a 1.0 L sample solution at pH 5.0. After 2.0 mL of 0.2%(w/v) Triton X-100 was added, the ion pairs were extracted into 20.0 mL MIBK in a flotation cell by bubbling. The analytes were determined by a calibration curve method with measured absorbances in MIBK, and the recovery was 80-120%.

AN EXPERIMENTAL STUDY ON THE CHEMICAL BOND STRENGTH AT THE INTERFACE BETWEEN PORCELAIN AND SUCCESSIVELY RECAST PALLADIUM-SILVER CERAMIC ALLOY (팔라디움-은합금의 반복주조시 도재와 금속간의 화학적 결합에 관한 실험적 연구)

  • Kim, Tae-Kyun;Lee, Sun-Hyung;Yang, Jae-Ho;Chong, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.31-47
    • /
    • 1989
  • The purpose of this study was to evaluate the chemical bond strength of successively recast Pd-Ag ceramic alloys with porcelain and to investigate changes of quantity of trace elements at the metal-porcelain interface. Porcelain was fired as usual manner on the each successively recast specimen. Rectangular planar shear test was performed and bond strength was measured by Instron universal testing machine. Diffusion of trace elements at the each interface was observed by ESCA (Electron Spectroscopy for Chemical Analysis). The obtained results were as follows : 1. Chemical bond strength was significantly decreased after second recasting. But in case of first recasting, there was no significant decrease of bond strength statistically (p<0.05). 2. Bond strength was not significantly decreased in each generation, when fifty percents new alloy was added (p<0.05). 3. Ag, Sn and In were observed at the porcelain interface. But Pd was not observed. 4. The quantity of Ag, In ions were progressively increased at the metal-porcelain interface as the casting was repeated. Silver ion was most significantly increased.

  • PDF

Development of Schiff Base Column and Glow Discharge Detector for HPLC : Preliminary Study I (HPLC용 Schiff Base 컬럼과 Glow Discharge 검출기의 개발에 관한 기초연구 I)

  • Kang, Mi-Ra;Kim, Eun-Soo;Shin, Jung-Sook;Park, Hyun-Kook;Yang, Jung-Sung;Lee, Sang C.
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.265-272
    • /
    • 1995
  • Schiff base ligand columns and glow discharge detector have been developed for the trace analysis of metal ions desolved in water. Various types of hydrazide Schiff base ligands have been used and, additionally, they were examined as a filling material of a HPLC column. The hydrazide Schiff base ligands used were N, N'-oxalybis(salicylaldehydrazone) (OBSH), N, N'-malonylbis(salicylaldehydrazone) (MBSH), and N, N'-succinylbis(salicylaldehydrazone) (SBSH). A mixture of Schiff base ligand and poly(styrene divinylbenzene) was examined and it showed a smooth flow of solution. The OBSH-polymer column demonstrated different effluent factors for different metal ions. Metal ions in eluates were detected by Hollow Cathode Glow Discharge-Atomic Emission Spectrometry(HCGD-AES). HCGD-AES showed good sensitivity and selectivity. This is only the preliminary results of new OBSH-polymer column and glow discharge detector.

  • PDF

Application of Polyurethane Foam Loaded with a Schiff Base Ligand for Determination of Trace Amounts of Copper in Water Samples by Flame Atomic Absorption Spectroscopy

  • Moftakhar, Mahdieh Koorehpazan;Yaftian, Mohammad Reza;Nahaei, Samaneh;Zamani, Abbas Ali
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.3
    • /
    • pp.283-288
    • /
    • 2014
  • A column solid phase extraction procedure based on modified polyurethane foam (PUF) by a newly synthesized Schiff base ionophore, named 2,2'-{iminobis[propane-3,1-diylnitrilo(1E)prop-1-yl-1-ylidene]}diphenol, was developed for preconcentration step of trace amounts determination of copper ions in water samples by atomic absorption flame spectroscopy. The influence of parameters on the adsorption process such as sample pH, amount of modified PUF packed in the column, type and volume of stripping reagent and its flow rate were investigated and optimized. Under optimum experimental conditions, the calibration graph was linear in a relatively wide range ($0.005-210{\mu}g/ml$) with a limit of detection $0.002{\mu}g/ml$ of copper. The proposed method allows achieving to a concentration factor of >133. The capacity of a column (1.6 cm i.d.) packed by 6 g of PUF modified by 12 mg of the Schiff base was found to be $247.7({\pm}2.1){\mu}g$ of copper. It was found that the adsorption process was highly selective towards copper ions with respect to some associated metal ions. The presented procedure was successfully applied for determination of copper in some water samples.

Metal Ion Release Behaviour and Cytotoxicity of a Super Stainless Steel (초내식성 스테인레스강의 금속이온용출특성 및 세포적합성)

  • Kim, Cheol-Sang;Park, Jin-Soo;Her, Erk;Khang, Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 1996
  • The toxic metal ion release behaviour and the cytotoxicity of a super stainless steel (S.S.S, 22cr-20Ni -6Mo-0.25N) were investigated The measurement of the amount of static and wear- induced trace metal ion released from the steels was conducted in Hank's balanced salt solution using an electrothermal atomic absdrption spectrometry equiped with Uaphite furnace. And the in vitro cytotoxicity of the materials was assesed in cell culture. The static dissolution rates of Fe and Cr ions from the S.S.S were significantly lower than those of 316L SS. However, the Ni ion release from the S.S.S during the first 4 weeks was yester than that from 316L 55 by 15-45%. Also, the wear-in- duces dissolution rates from the steels were not correlated either with their elemental composition rates or with the static metal ion release rates. The S.S.S did not deteriorate the osteoblasts viability. And no toxic response was observed from the macrophages cultured for 7 days in RFMI 1640 medium immersed with the S.S.S specimens.

  • PDF

Chemical Composition of Rainwater in Chonju-city, Korea (전주시에서 채수된 강수의 화학적 조성)

  • 나춘기;정재일
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.5
    • /
    • pp.371-381
    • /
    • 1997
  • Precipitation sampls were collected in Chonju-city during October 1994 to September 1995 and were analysed for major ions (N $a^{+}$, $K^{+}$, $Ca^{2+}$, $Mg^{2+}$, C $l^{[-10]}$ , NO/$_3$, S $O_4$$^{2-}$) and trace metals (Al, Cd, Ni, Pb, Sr, Zn) in addition to pH, in order to understand the chemical characteristics of acid rain and to estimate the origin of the determined ions. Most rain showed a neutral or alkaline character, and only 35% had a pH lower than 5.6. S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ are identified as the primary contributors to precipitation acidity in this region. Neutralization of precipitation acidity occurs as a result of the dissolution of alkaline compounds containing $Ca^{2+}$, $Mg^{2+}$ and $K^{+}$. S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ precipitation concentrations exhibit a seasonal pattern in which higher concentrations are observed during spring months and lower concentrations during summer months. However, the seasonal behavior of $H^{+}$ concentrations differs from this pattern, in that the highest concentrations occur during autumn months, owing to the different influence of neutralization processes. In all rain, S $O_4$$^{2-}$ concentration exceeded NO/$_3$$^{[-10]}$ concentration. The contribution of maritime sources to the total S $O_4$$^{2-}$ concentration was very low or negligible. For rain strongly affacted by yellow sand, $Ca^{2+}$, $Mg^{2+}$ and $K^{+}$ ions show a sharp increase in concentration, reflecting the increased amount of dust and soil suspended in atmosphere. At the same time, S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ concentrations are at their highest levels while $H^{+}$ values are not comparably elevated, presumably beacause much of the acidity has been neutralized by alkaline substances. The seasonal variance of trace metal concentrations in rainwater is similar to that of major cations. The annual wet flux of acidic pollutants and trace metals wat calculated to be as follows: N $O_3$$^{[-10]}$ ; 2.32 g/$m^2$, S $O_4$$^{2-}$, 5.34 g/$m^2$, Al; 6.30 mg/$m^2$, Cd; 0.62 mg/$m^2$, Ni; 4.08 mg/$m^2$, Pb: 9.76 mg/$m^2$, Sr; 5.94 mg/$m^2$, Zn; 111 mg/$m^2$./$m^2$.

  • PDF