• Title/Summary/Keyword: Trabecular

Search Result 360, Processing Time 0.026 seconds

Nondestructive Estimation of Mechanical Orthogonality of Human Trabecular Bone by Computed Tomography and Spherical Indentation Test

  • Bae Tae Soo;Lee Tae Soo;Choi Kuiwon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • The elastic modulus and the apparent density of the trabecular bone were evaluated from spherical indentation tests and Computed Tomography (CT) and their relationship was quantified. The femurs were prepared for trabecular bone analysis. Embedded with respect to their anatomical orientation, the transverse planes of the trabecular bone specimens were scanned at 1㎜ intervals using a CT scanner. The metaphyseal regions of femurs were sectioned with a diamond-blade saw, producing 8㎜ cubes. Using a specially made spherical indentation tester, the cubes were mechanically tested in the anterior-posterior (AP), medial-lateral (ML), and inferior-superior (IS) directions. After determination of modulus from the mechanical testing, the apparent densities of the specimens were measured. The results showed that the IS modulus was significantly greater than both the AP and ML moduli with the AP modulus greater than the ML modulus. This demonstrated that orthogonality was a structural characteristic of the trabecular bone. The power relationship between the modulus and the apparent density was also found to be statistically significant.

THE EFFECTS OF DIETARY CONSISTENCY ON THE TRABECULAR BONE ARCHITECTURE IN GROWING MOUSE MANDIBULAR CONDYLE : A STUDY USING MICRO-CONFUTED TOMOGRAPHY (성장 중인 쥐에서 음식물의 경도가 하악 과두의 해면골에 미치는 영향 : 미세전산화 단층촬영을 이용한 연구)

  • Youn, Seok-Hee;Lee, Sang-Dae;Kim, Jung-Wook;Lee, Sang-Hoon;Hahn, Se-Hyun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.228-235
    • /
    • 2004
  • The development and proliferation of the mandibular condyle can be altered by changes in the biomechanical environment of the temporomandibular joint. The biomechanical loads were varied by feeding diets of different consistencies. The purpose of the present study was to determine whether changes of masticatory forces by feeding a soft diet can alter the trabecular bone morphology of the growing mouse mandibular condyle, by means of micro-computed tomography. Thirty-six female, 21 days old, C57BL/6 mice were randomly divided into two groups. Mice in the hard-diet control group were fed standard hard rodent pellets for 8 weeks. The soft-diet group mice were given soft ground diets for 8 weeks and their lower incisors were shortened by cutting with a wire cutter twice a week to reduce incision. After 8 weeks all animals were killed after they were weighed. Following sacrifice, the right mandibular condyle was removed. High spatial resolution tomography was done with a Skyscan Micro-CT 1072. Cross-sections were scanned and three-dimensional images were reconstructed from 2D sections. Morphometric and nonmetric parameters such as bone volume(BV), bone surface(BS), total volume(TV), bone volume fraction(BV/TV), surface to volume ratio(BS/BV), trabecular thickness(Tb. Th.), structure model index(SMI) and degree of anisotropy(DA) were directly determined by means of the software package at the micro-CT system. From directly determined indices the trabecular number(Tb. N.) and trabecular separation(Tb. Sp.) were calculated according to parallel plate model of Parfitt et al.. After micro-tomographic imaging, the samples were decalcified, dehydrated, embedded and sectioned for histological observation. The results were as follow: 1. The bone volume fraction, trabecular thickness(Tb. Th.) and trabecular number(Tb. N.) were significantly decreased in the soft-diet group compared with that of the control group (p<0.05). 2. The trabecular separation(Tb. Sp.) was significantly increased in the soft-diet group(p<0.05). 3. There was no significant differences in the surface to volume ratio(BS/BV), structure model index(SMI) and degree of anisotropy(DA) between the soft-diet group and hard-diet control group (p>0.05). 4. Histological sections showed that the thickness of the proliferative layer and total cartilage thickness were significantly reduced in the soft-diet group.

  • PDF

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.

Detecting and Tracking Changes of Mechanical Characteristics of the Trabecular and Cortical Bone in the Lumbar Vertebrae of an OVX Rat - Use of In-Vivo Micro-CT and Micro-FE Analysis - (난소 절제술을 시행한 흰쥐 등뼈의 해면골과 피질골의 구조적 특성 추적관찰 및 기계적 특성 분석 - 생체 내 미세단층촬영 시스템과 미세 유한요소법 적용 -)

  • Ko, Chang-Yong;Woo, Dae-Gon;Lee, Tae-Woo;Lee, Beob-Yi;Tack, Gye-Rae;Kim, Han-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.110-117
    • /
    • 2007
  • This study investigated changes of mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae of the ovariectomised (OVX) rat. In previous researches, there were many studies for morphology of osteoporotic bones based on Micro-Computed Tomography (Micro-CT). However, there were few studies for detecting and tracking changes of mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae of the OVX rat. For this study, the 4th lumbar of the OVX rat (female Sprague-Dawley) was utilized as a specimen. An OVX rat was scanned at week 0 (just before surgery), at week 4, and week 8 after surgery. Micro-finite element (${\mu}-FE$) analysis was used to investigate mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae for an OVX rat. When the OVX rat (at week 8) was compared with the OVX rat (at week 0), the structural modulus of cortical and trabecualr bone was decreased by 52% and 99%, respectively. This study showed the change of mechanical characteristics of cortical bone as well as trabecular bone of an OVX rat. Detecting and tracking changes of mechanical characteristics could greatly contribute to an experiment test for the trabecular and cortical bone in the lumbar vertebrae of an OVX rat by using In-vivo Micro-CT.

Micro-Structural Profiles of Trabecular Bone at the Ankle Joint (족관절 해면골의 미세 구조 분석)

  • Kim, Hyon-Jeong;An, Tae-Sun;Baek, Myong-Hyun;Choi, Mun-Kwon;Won, Ye-Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.157-160
    • /
    • 2004
  • Purpose: This study aimed to investigate and compare the micro-structural profiles of trabecular bone from different facets at the ankle joint. Materials and Methods: In a fresh cadaver ankle, four cored 10 mm of diameter cylindrical specimens of trabecular bone were harvested from the distal tibia, the talar dome, the medial malleolus, and the lateral malleolus. Using a micro-computed tomography, two-dimensional and three-dimensional micro-structural indices of the trabecular bone were analyzed. Results: Each specimen from the tibia, talus, medial malleolus, and the lateral malleolus showed unique micro-structural pattern. Tibia versus talus, the talus was seen a higher bone volume fraction and a wider supporting zone subchondrally whereas the tibia was seen a relatively lower bone volume fraction and a much narrower supporting zone subchondrally. Lateral malleolus versus medial malleolus, the lateral malleolus was seen the thicker but sparse trabeculae pattern whereas the medial malleolus was seen the thinner but more compact trabecular pattern. Conclusion: Each four locations from the different facet at the ankle joint have distinct own micro-structural patterns of the trabecular bone, suggesting different mechanical properties.

  • PDF

Influence of Cortical Endplates on Ultrasonic Properties of Trabecular Bone (피질골판이 해면질골의 초음파 특성에 미치는 영향)

  • Kim, Yoon Mi;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • The present study investigated the influence of thick cortical endplates on the ultrasonic properties of trabecular bone in a femur with a high fracture risk. Twelve trabecular bone samples were prepared from bovine femurs, and acrylic plates with thicknesses of 1.25, 1.80, and 2.75 mm were manufactured to simulate the cortical endplates using acrylic with a density and a sound speed similar to cortical bone. Although the thickness of the acrylic plates attached to the two sides of the trabecular bone increased, high correlations were observed between the speed of sound and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.80-0.86. High correlations were also observed between the attenuation coefficient at 0.5 MHz and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.84-0.91. These results suggest that the speed of sound and attenuation coefficient at a specific frequency measured in a femur with relatively thick cortical endplates compared to the calcaneus could be used as indices for predicting the bone mineral density of the femur.

The three-dimensional microstructure of trabecular bone: Analysis of site-specific variation in the human jaw bone

  • Kim, Jo-Eun;Shin, Jae-Myung;Oh, Sung-Ook;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul;Huh, Kyung-Hoe
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.227-233
    • /
    • 2013
  • Purpose: This study was performed to analyze human maxillary and mandibular trabecular bone using the data acquired from micro-computed tomography (micro-CT), and to characterize the site-specific microstructures of trabeculae. Materials and Methods: Sixty-nine cylindrical bone specimens were prepared from the mandible and maxilla. They were divided into 5 groups by region: the anterior maxilla, posterior maxilla, anterior mandible, posterior mandible, and mandibular condyle. After the specimens were scanned using a micro-CT system, three-dimensional microstructural parameters such as the percent bone volume, bone specific surface, trabecular thickness, trabecular separation, trabecular number, structure model index, and degrees of anisotropy were analyzed. Results: Among the regions other than the condylar area, the anterior mandibular region showed the highest trabecular thickness and the lowest value for the bone specific surface. On the other hand, the posterior maxilla region showed the lowest trabecular thickness and the highest value for the bone specific surface. The degree of anisotropy was lowest at the anterior mandible. The condyle showed thinner trabeculae with a more anisotropic arrangement than the other mandibular regions. Conclusion: There were microstructural differences between the regions of the maxilla and mandible. These results suggested that different mechanisms of external force might exist at each site.

Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study

  • Tayman, Mahmure Ayse;Kamburoglu, Kivanc;Ocak, Mert;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.171-179
    • /
    • 2022
  • Purpose: The aim of this study was to assess the accuracy of cone-beam computed tomographic (CBCT) images obtained using different voxel sizes in measuring trabecular bone microstructure in comparison to micro-CT. Materials and Methods: Twelve human skull bones containing posterior-mandibular alveolar bone regions were analyzed. CBCT images were obtained at voxel sizes of 0.075mm(high: HI) and 0.2mm(standard: Std), while microCT imaging used voxel sizes of 0.06 mm (HI) and 0.12 mm (Std). Analyses were performed using CTAn software with the standardized automatic global threshold method. Intraclass correlation coefficients were used to evaluate the consistency and agreement of paired measurements for bone volume (BV), percent bone volume (BV/TV), bone surface (BS), trabecular thickness (TbTh), trabecular separation (TbSp), trabecular number (TbN), trabecular pattern factor(TbPf), and structure model index (SMI). Results: When compared to micro-CT, CBCT images had higher BV, BV/TV, and TbTh values, while micro-CT images had lower BS, TbSp, TbN, TbPf, and SMI values (P<0.05). The BV, BV/BT, TbTh, and TbSp variables were higher with Std voxels, whereas the BS, TbPf, and SMI variables were higher with HI voxels for both imaging methods. For each imaging modality and voxel size evaluated, BV, BS, and TbTh were significantly different(P<0.05). TbN, TbPf, and SMI showed statistically significant differences between imaging methods(P<0.05). The consistency and absolute agreement between micro-CT and CBCT were excellent for all variables. Conclusion: This study demonstrated the potential of high-resolution CBCT imaging for quantitative bone morphometry assessment.

Effect of Cortical Bone on Acoustic Properties of Trabecular Bone in Bovine Femur In Vitro (생체 외 조건의 소 대퇴골에서 해면질골의 음향특성에 대한 피질골의 효과)

  • Hwang, Kyo Seung;Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.181-189
    • /
    • 2013
  • The purpose of the present study is to investigate the effect of cortical bone on acoustic properties of trabecular bone, such as speed of sound (SOS) and normalized broadband ultrasound attenuation (nBUA), in bovine femur in vitro. Twelve trabecular bone samples and three cortical bone plates with thicknesses of 1.00, 1.47, and 2.00 mm were extracted from the proximal end of two bovine femurs. The correlations between acoustic properties and trabecular apparent bone density were also examined before and after attaching a cortical bone plate to the trabecular bone samples. SOS increased linearly with increasing thickness of the cortical plate attached to one side of ultrasonic incidence of the trabecular bone samples, whereas nBUA showed a nonlinear dependence on the thickness of the cortical plate. All the SOS (r = 0.95-0.97) and nBUA (r = 0.53-0.73) measurements with and without the cortical bone plate with various thicknesses were found to exhibit high correlations with the trabecular apparent bone density. These results imply that the acoustic properties measured in the femur with lateral cortical layers in vitro can be useful indices for the prediction of trabecular bone mineral density.