• 제목/요약/키워드: Toxic Gas

검색결과 491건 처리시간 0.031초

철도차량용 재료의 독성성분 정량화 향상기법 연구 (The improvement of quantification method of toxic gas components from the materials of the railway vehicle)

  • 이철규;정우성;이덕희;이관섭;박지영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1314-1317
    • /
    • 2007
  • This study is on the fire resistance evaluation method, expecially on the toxicity of smoke gases generated from the fire, of materials for railway car and structures. Until now, Although international standard related to the quantifying evaluation method of smoke gas is provided but the specific procedure is not contained. On this reason, Test results of toxicity show deviation with the different technique being applied. For now, In advanced railway country, various instrument, like ion chromatography and etc., is used but FT-IR is recommended due to its lots of advantages. while FT-IR has a lot of strong points but still has some problems like water vapor interferences. In this paper, To improve credibility and repeatability of FT-IR it contains some technical solutions in quantifying the 8 toxic components.

  • PDF

독성가스 용기 유통 이력 추적 관리 기술 개발 (A development of toxic gas cylinders traceability technology)

  • 박길주;이창열;조영도
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2015년 정기학술대회
    • /
    • pp.212-214
    • /
    • 2015
  • 독성가스는 반도체, LCD, 태양전지 등 첨산 산업 발달로 그 수요가 증가하고 있으나, 독성가스 용기 무단폐기 등 관리 및 유통에 대한 체계가 열악한 실정이다. 독성가스를 제조 유통하는 시설이 2013년 기준으로 2,774개소가 있으며, 2012년 가스사용량은 2010년 대비 62.5% 급증하였다. 대학교, 연구소 등 사용량은 적으나 독성가스를 사용하지만 고압가스안전관리법의 검사 대상에서 제외되는 기관도 4천개 이상이 되는 상태에서 이에 대한 유통 이력 추적 관리는 매우 중요한 상태이다. 이에 따라 본 연구에서는, RFID를 이용하여 독성가스 용기의 제조, 유통, 충전 및 폐기 전 영역에서 이력정보를 관리하는 독성가스 용기 유통 이력추적관리기술을 개발하였으며, 본 기술을 통하여 투명하고 추적 가능한 독성가스 용기 관리 체계를 갖추었다.

  • PDF

COMBUSTION TOXICITY ANALYSIS: ADVANCES USING A SPECIALIZED SAMPLING TECHNIQUE FOR FOURIER TRANSFORM INFRARED (FTIR) ANALYSIS

  • Talandis, Jonas;Innes, J.D.;Cox, A.W.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.178-184
    • /
    • 1997
  • The cone calorimeter as defined by ISO 5660, ASTM 1354, and NFPA 264A is used to assess the reaction to fire of almost any material that must be evaluated in the fire science field. Typical combustion gas analyses include oxygen, CO and CO2. Oxygen consumption is used to determine rate of heat release. Analysis of combustion gases other than oxygen, CO and CO2 has been attempted using filters to remove the solid smoke particles before analysis. This method has generated unreliable results due to the adsorption of many gas components on the active carbon . particles deposited on the filters. A technique using fourier Transform Infrared (FTIB) analysis without filtration will be disclosed and a discussion will be presented of the analytical results of toxic gases produced from various flame retarded polymeric materials. Use of such data in lethal toxic potency determinations is also reviewed.

  • PDF

SAW 센서의 제작 및 독성화학물질 감도특성 연구 (A study on the fabrication of polymer-coated SAW sensors and their sensing properties for some toxic chemical compounds)

  • 임양례;박병황;최선경;송갑득;이덕동
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.143-146
    • /
    • 2008
  • Polymer-coated film SAW sensors have been fabricated and their sensing properties for toxic chemicals have been extensively investigated. Four types of the toxic chemical compounds of hydrogen cyanide(AC), carbonyl dichloride(CG), pinacolyl methylfluorophosphonate(GD), 2,2'-dichlorodiethylthio ether(HD) were used as target gases. SAW sensors using five different kinds of polymers were used to detect toxic chemicals and their gas sensing characteristics were investigated. The polymers used as the sensing materials were polyisobutylene(PIB), polyepichlorohydrin(PECH), polydimethylsiloxane(PDMS), polybutadiene(PBD) and polyisoprene(PIP). The recommendable mixing ratio of PIB, PECH, PDMS, PBD and PIP to solvents were 1:30, 1:40, 1:10, 1:30 and 1:30, respectively. The sensing characteristics of the SAW sensors were measured by using E-5061A network analyzer.

CuO가 첨가된 WO3 후막 가스센서 특성 연구 (Characteristics of CuO doped WO3 Thick Film for Gas Sensors)

  • 유일;이돈규;신덕진;유윤식
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1621-1625
    • /
    • 2010
  • Recently, due to increase in the usage of toxic gas and inflammability gas, the ability to monitor and precisely measurement of these gases is crucial in preventing the occurrence of various accidents. CuO doped and undoped $WO_3$ thick films gas sensors were prepared using screen-printing method on alumina substrates. A structural properties of $WO_3$:CuO thick films had monoclinic phase and triclinic phase of $WO_3$ together. Sensitivity of $WO_3$:CuO sensor at 2000 ppm of $CO_2$ gas and 50 ppm of $H_2S$ gas was investigated. 4 wt% Cu doped $WO_3$ thick films had the highest sensitivity of $CO_2$ gas and $H_2S$ gas.

기존 건축물을 용도변경한 노인의료복지시설의 화재 인명피해 예방과 피난 대책 -광주·전남 농촌지역을 중심으로- (Prevention of Human injury and Countermeasure of evacuation about Fire of Nursing Homes by Conversion of existing buildings - Focused on rural areas in Gwangju and Jeonnam -)

  • 김현태;김원진
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.27-36
    • /
    • 2018
  • At present, the elderly population in Korea is 14% of the total population and then We has entered an the society of advanced age. Along with this, elderly people with dementia and palsy are also increasing. The demand for elderly nursing homes for elderly people with severe diseases such as dementia and stroke is also increasing, and the existing buildings are being secured by Conversion of existing buildings. However, it is difficult to evacuate and fire due to the out of date of buildings by Conversion of existing buildings. For example, there is a fire in the Indukukwon, Pohang City and Hyosung Geriatric Hospital, Jangseong in Korea, which have changed the use of existing buildings. Many elderly people died in a night fire. It was because of the sandwich panel walls and PVC flooring material produced toxic gas instantly. In this study, we investigated the nursing home that changing the use and established fire prevention of human injury and countermeasure of evacuation. First, the sandwich panels which leading to deaths due to the toxic gas were installed in most nursing home. We recommend the RC, the masonry wall, and the glass fiber panel instead of the sandwich panels, In addition, the PVC flooring is most used in nursing home, the flooring material is considered such as the building stones, the tile, and the yellow soil closing instead of the PVC flooring. Second, we investigated the installation status of fire fighting equipment. As a result, the automatic-emergency open&shut equipment, the smoke ventilator and the evacuation slide were rarely installed. In order to secure the golden time in case of fire and to prevent the asphyxia caused by the toxic gas, the law should be amended to install the equipment.

중규모 도로터널의 제연경계벽 설치에 따른 연기확산특성 (Study of the Characteristics of Smoke Spread by an Installing Smoke Barrier in Medium Length Road Tunnel)

  • 백두산;이승철
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.9-17
    • /
    • 2016
  • 중규모 도로터널의 경우 제연설비 설치가 의무화 되어있지 않기 때문에 화재가 발생할 경우 이용객들이 많은 피해를 입을 수 있다. 따라서 본 연구에서는 연장 1,000 m 2차로 일방통행방식의 도로터널을 대상으로 3차원 수치해석, 정량적 위험도 평가를 통해 제연경계벽이 설치되지 않을 때와 설치간격이 100, 150, 200, 250 m일 때 화재에 의하여 발생되는 연기류 등이 시간에 따른 확산을 분석하였다. 그 결과 중규모 도로터널에 제연경계벽을 설치할 경우 설치하지 않은 경우보다 화재로부터 발생되는 고온의 공기와 독성가스의 확산이 지연되는 것을 확인할 수 있었다. 또한 수치해석 대상 중에서 제연경계벽의 설치간격이 100 m인 경우 화재로 인해 발생된 고온의 공기와 독성가스의 확산이 다른 경우보다 많이 지연되어 터널 이용객이 피난하는데 가장 적합한 것으로 나타났다.

GRA(Generic Risk Analysis) 기법을 이용한 공기분리시설에 대한 준 정량적 위험성 평가에 관한 연구 (A Study on Semi Quantitative Risk Analysis for Air Separation Unit using a GRA(Generic Risk Analysis) Method)

  • 신정수;변헌수
    • 한국가스학회지
    • /
    • 제17권1호
    • /
    • pp.56-66
    • /
    • 2013
  • 가스제조 시설들은 불활성 가스공급을 통하여 제조업 시설의 안전한 운영 및 유지하는 역할을 하며, 폭발성, 가연성 및 독성가스를 공급하여 화학제품 제조에 필요한 기초 원료의 공급을 담당하는 역할을 한다. 또한 가스의 제조과정에서 고온, 고압, 초저온 및 촉매반응 등의 운전조건 하에서 시설이 운전되기 때문에 안전하고 신뢰성 있는 운영이 반드시 필요하다. 이러한 공장들은 공정관리가 복잡하며 제조물질의 누출로 인한 화재, 폭발 및 독성가스 누출로 인한 중대산업사고의 위험성이 있고, 불활성가스로 인한 질식재해, 고온 및 초저온으로 인한 화상 등 잠재적인 위험요소를 많이 가지고 있다. 본 연구는 신뢰성 있는 준 정량적 위험성평가 기법인 GRA(Generic Risk Analysis) 모델을 공기분리시설(ASU)에 적용하여 초기위험도(Initial Risk) 산정, 안전방벽(Safety Barriers) 적용, 잔여위험도(Residual Risk) 산정 및 중요안전요소(EIS, Elements Important for Safety)를 도출 하였으며, 위험성 평가 결과로 도출된 중요안전요소에 대한 효과적인 안전관리 및 시행절차의 구축을 제안하였다.

Effect of Substrate Temperature and Post-Annealing on Structural and Electrical Properties of ZnO Thin Films for Gas Sensor Applications

  • 도강민;김지홍;노지형;이경주;문성준;김재원;박재호;조슬기;신주홍;여인형;문병무;구상모
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.105-105
    • /
    • 2011
  • ZnO is a promising material since it could be applied to many fields such as solar cells, laser diodes, thin films transistors and gas sensors. ZnO has a wide and direct band gap for about 3.37 eV at room temperature and a high exciton binding energy of 60 meV. In particular, ZnO features high sensitivity to toxic and combustible gas such as CO, NOX, so on. The development of gas sensors to monitor the toxic and combustible gases is imperative due to the concerns for enviromental pollution and the safety requirements for the industry. In this study, we investigated the effect of substrate temperature and post-annealing on structural and electrical properties of ZnO thin films. ZnO thin films were deposited by pulsed laser deposition (PLD) at various temperatures at from room temperature to $600^{\circ}C$. After that, post-annealing were performed at $600^{\circ}C$. To inspect the structural properties of the deposited ZnO thin films, X-ray diffraction (XRD) was carried out. For gas sensors, the morphology of the films is dominant factor since it is deeply related with the film surface area. Therefore, the atomic force microscopy (AFM) and field emission scanning electron microscopy (FE-SEM) were used to observe the surface of the ZnO thin films. Furthermore, we analyzed the electrical properties by using a Hall measurement system.

  • PDF

[논문철회]화재용 방독면의 CO, HCl, HCN, SO2 연소생성물 제거효율 ([Retracted]Gas Mask Removal Efficiency of CO, HCl, HCN, and SO2 Gas Produced by Fire)

  • 공하성;공예솜;김상헌
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.57-60
    • /
    • 2015
  • 화재 시 발생하는 독성 가스인 CO, HCl, HCN, $SO_2$를 방독면에 의해 제거하는 효율은 화재로 인한 인명구조의 핵심 요소이다. 머리와 목끈이 없는 탄력있는 방독면은 전방을 주시할 수 있는 창, 탄력후드, 가스정화기와 공기 환풍구로 되어 있어서 화재 시 빠르고 쉽게 착용할 수 있다. 이 연구에서는 이러한 방독면의 CO, HCl, HCN, $SO_2$ 제거 효율에 대한 연구를 진행하였다. 실험결과 CO 제거 효율은 최초 농도가 2505.0 ppm인 경우 3.5분 후에 99.99%였고, 8.5분 후에는 99.98%로 나타났다. 8.5분 후에는 CO 농도가 급격히 증가하는 특성을 보였다. HCl, HCN, $SO_2$에 대해서는 최초 농도가 각각 1003.0, 399.0, 100.3 ppm인 경우 20분 동안 제거 효율이 100%로 나타났다.