• Title/Summary/Keyword: Tower approach

Search Result 123, Processing Time 0.028 seconds

Ministry of Taxation Tower in Baku, Azerbaijan: Turning Away from Prescriptive Limitations

  • Choi, Hi Sun;Ihtiyar, Onur;Sundholm, Nickolaus
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.377-386
    • /
    • 2020
  • Beginning a few decades ago, Baku, the capital city of Azerbaijan, has experienced a dramatic construction boom that is revitalizing its skyline. The expansive growth looks to uphold the historic past of Baku as a focal point within the Caspian Sea Region while also evoking aspirations for a city of the future. With superstructure complete and interiors progressing, the Ministry of Taxation (MOT) tower is the latest addition to the city, with its stacked cubes twisting above a multi-level podium at the base. Each cube is separated by column-free green roof terraces, creating unique parametric reveals of the developing surroundings. Aside from MOT's stunning shape, its geolocation resulted in unusually high wind loads coupled with high seismic hazards for a tower of its height. In addition, limitations on possible structural systems required stepping away from a typical prescriptive code-based approach into one that utilized Performance-Based Design (PBD) methods. This paper presents the numerous structural challenges and innovations that allowed the design of a new icon to be realized.

Optimization of Luffing-Tower Crane Location in Tall Building Construction

  • Lee, Dongmin;Lim, Hyunsu;Cho, Hunhee;Kang, Kyung-In
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.420-424
    • /
    • 2015
  • The luffing-tower crane (T/C) is a key facility used in the vertical and horizontal transportation of materials in a tall building construction. Locating the crane in an optimal position is an essential task in the initial stages of construction planning. This paper proposes a new optimization model to locate the luffing T/C in the optimal position to minimize the transportation time. An optimization algorithm, the Harmony Search (HS) algorithm, was used and the results show that HS has high performance characteristics to solve the optimization problem in a short period of time. In a case study, the proposed model offered a better position for T/C than the previous heuristic approach.

  • PDF

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

Unsteady Flow Analysis Around a HAWT System Using Sliding Mesh Technique (미끄럼 격자를 이용한 HAWT 시스템 주위의 비정상 유동장 해석)

  • Lee, Chi-Hoon;Kim, Sang-Gon;Joh, Chang-Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.3
    • /
    • pp.201-209
    • /
    • 2011
  • An unsteady RANS analysis study of the 3-D flow around the NREL Phase VI horizontal axis wind turbine(HAWT) was performed using sliding mesh approach. Two different analysis models such as rotor-only and rotor with tower/nacelle were constructed to investigate the blade/tower interaction. Analysis results for the rotor with tower/nacelle were compared with the corresponding NREL's experimental data which produced fairly good validation of the present CFD model. Comparison of flows around those two models also clearly showed the blade/tower interaction even it was small for upwind configuration. Other visualization results and integrated aerodynamic loads including torque of the blade demonstrated the effective unsteady flow simulation capability of the present CFD model.

Numerical Study for the Performance Analysis and Design of a Crossflow- Type Forced Draft Cooling Tower

  • Choi, Young-Ki;Kim, Byung-Jo;Lee, Sang-Yun;Lee, Jung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.1-13
    • /
    • 2000
  • A numerical study for performance analysis of a crossflow-type forced draft cooling tower has been performed based on the finite volume method with non-orthogonal body fitted, and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy, moisture fraction, water enthalpy, and water mass balance equations are solved with Navier-Stoke's equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study. The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also performed.

  • PDF

Development of Nonlinear Analysis Technic to Determine the Ultimate Load in Electric Transmission Tower (송전철탑의 극한하중 도출을 위한 비선형해석 기법)

  • Kim, Woo Bum;Choi, Byong Jeong;Ahn, Jin Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.3
    • /
    • pp.389-398
    • /
    • 2008
  • The current design practice of electric transmission tower is based on the allowable stress design. However, it is difficult to find the cause behind a transmission tower's collapse by the above design approach as the collapse is caused by large secondary deformations based on and geometrical nonlinear behavior.influence factor for the nonlinear behavior is mainly residual stress, initial imperfection and end restraints on members. In this study, the necessity of the nonlinear analysis is examined through the comparison between elastic ana the nonlinear analysis, a new analytical method (equivalent nonlinear analysis technique) is proposed. To confirm the reliability of the proposed method, the computed ultimate load of the transmission tower using the method was compared with that of the nonlinear finite element analysis. Effects of parameters, such as compressive force and the slenderness ratio of the brace member on the main post member, were investigated. The effective member length according to influential parameters was formulated in table form for practical purposes.

Cooling Performance of Cooling Tower-Assisted Ground-Coupled Heat Pump (GCHP) System Applied in Hospital Building (병원 건물에 설치된 냉각탑 병용 지열 히트펌프 시스템의 냉방 성능)

  • Sohn, Byonghu;Lee, Doo-Young;Min, Kyung-Chon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • This paper presents the measurement and analysis results for the cooling performance of ground-coupled heat pump (GCHP) system using a cooling tower as a supplemental heat rejector. In order to demonstrate the performance of the hybrid approach, we installed the monitoring equipments including sensors for measuring temperature and power consumption, and measured operation parameters from May 1 to October 30, 2014. The results showed that the entering source temperature of brine returning from the ground heat exchanger was in a range of design target temperature. Leaving load temperatures to building showed an average value of $11.4^{\circ}C$ for cooling season. From the analysis, the daily performance factor (PF) of geothermal heat pumps ranged from 4.4 to 5.2, while the daily PF of hybrid GCHP system varied from 3.0 to 4.0 over the entire cooling season.

A Study on Fault Prediction Method in a Pump Tower of LNG FPSO (LNG FPSO 펌프타워 고장 예지 방안에 관한 연구)

  • Kim, Yongjae;Cho, SangJe;Jun, Hong-Bae;Ha, Chunghun;Shin, Jongho
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.2
    • /
    • pp.111-121
    • /
    • 2016
  • The plant equipment usually has a long life cycle. During its O&M (Operation & Maintenance) phase, since the occurrence of an accident of offshore plant equipment causes catastrophic damage, it is necessary to make more efforts for managing critical offshore equipment. Nowadays due to the emerging ICTs (Information Communication Technologies) and sensor technologies, it is possible to gather the health status data of important offshore equipment and their environment data, which leads to much concern on CBM (Condition-Based Maintenance). In this study, we will propose an approach to estimate the remaining lifetime of an offshore plant equipment (pump tower) based on gathered ocean environment data.

A Study on the Characteristics of an Unit Plan for a Tower Type Super-High-Rise-Residence (탑상형 초고층 주거건축의 단위평면 특성에 관한 연구 - 외기접합 면수별 공간구성 특성을 중심으로 -)

  • 이용광
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.5
    • /
    • pp.90-97
    • /
    • 2004
  • The purpose of this study is to grasp the spatial characteristic of the unit plan for a Super-High-Rise-Residence. This study is focused on the open air contact sides for a tower type Super-High-Rise-Residence. A tower type Super-High-Rise-Residence which has open air contacts from 1 to 3.5 sides differed in spatial characteristics of the unit plan for other apartment units. The current study analyzed 188 unit plans for the size of 40 pyong or larger in Seoul and the metropolitan areas which have been built since 1990. Open air contact side was classified as under 2 sides, 2 sides, and over 2 sides. The unit plan which belong to each open air contact side was Investigated according to the location of public area, the relationship between livingroom and master bedroom, and a method of entry to the master bedroom. The results of this study are as follow: According to increase open air contact sides is changed the location of public area in unit plan from an typical arrangement to various arrangement. Also the relationship between livingroom and master bedroom becomes loose and in a method of entry to the master bedroom increase an indirect approach through other room.

New design concept and damage assessment of large-scale cooling towers

  • Noh, Sam-Young;Meskouris, Konstantin;Harte, Reinhard;Kratzig, Wilfried B.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.1
    • /
    • pp.53-70
    • /
    • 2003
  • The motivation of this paper is to introduce the modern technology of large-scale cooling tower design. Thereby the innovative design concept for the world's largest cooling tower with a height of 200 m is briefly presented (Harte & Kr$\ddot{a}$tzig 2002, Bush et al. 2002). The new concept was considered not only for safety, but also for preservation of the durability of the structure, because cracking damage in large cooling towers in general cause extremely high cost of maintenance and repair. The paper demonstrates numerically the damage process in large cooling towers (Kr$\ddot{a}$tzig et al. 2001), and describes some basics of the numerical finite element approach for damage propagation modelling of shell structure. A prototype is analysed to trace the progressive damage process, whereby the changes in the dynamical behaviour of the structure, as mirrored in its natural frequencies and the corresponding mode shapes, are presented and discussed. Finally, the example shows that such damage processes develop progressively over the life-time of the shell structure.