• Title/Summary/Keyword: Tower Structure

Search Result 435, Processing Time 0.024 seconds

Influence of Attached Mass/Masses on Natural Frequency of Vibration of Laminated Composite Plate for Bridge Deck (교량상판형(橋梁上板形) 적층복합판(積層復合板)의 진동수(振動數)에 대한 첨가질량(添加質量)의 영향(影響))

  • Sim, Do-Sik;Lee, Se-Jin;Kim, Kyung-Jin;Park, Je-Sun
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.123-129
    • /
    • 1996
  • A method of calculating the natural frequency corresponding to the first mode of vibration of beams and tower structures with irregular cross-sections and with arbitrary boundary conditions was developed and reported by D. H. Kim in 1974. In order to obtain the natural frequency by the presented method, the first step to take is to obtain the deflection influence surfaces. In design and analysis of any structure, the first step to be taken is to obtain this deflection influence surfaces. Any method can be used for this purpose. Then using this surfaces, deflections, slopes, moments, shears, and natural frequencies can be obtained by differentiating either the continuous function or discrete function defined at certain points. The merit of the presented method is that the natural frequency can be obtained by the deflection influence surfaces obtaining which is the first step in structural analysis.

  • PDF

Practical Use of Self Compacting Concrete to be filled inside the Steel Tube Columns (무다짐 콘크리트를 이용한 높은 40m CFT 기둥의 시공)

  • 김규동;김한준;손유신;이승훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1023-1028
    • /
    • 2003
  • The structure of Tower Palace III Sports Center building was designed as concrete Filled Steel Tube(CFT) Column and the filled-in concrete was designed as high compressive strength of 500kgf/$m_2$. The self compacting concrete(SCC, non-vibrating concrete) with 65$\pm$5cm flow must be applied to this case for filling the CFT by injecting the concrete from the column bottom. Laboratory tests and pilot productions of batcher plant were performed for optimum mix design and the full scale Mock-Up test was performed to check the appicability of the construction method. As a result, we observed that good quality SCC and the pressure change of concrete pump normally used domestically. Based on these results, we have constructed 20-40m height CFT columns successfully.

  • PDF

A Study of the 10 kW-Level Wind Turbine System by Controlled Hydraulic Torque Converter (10 kW급 유체 토크 컨버터를 이용한 풍력발전시스템에 관한 연구)

  • Jang, Mi-Hye;Kim, Dong-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.14-17
    • /
    • 2009
  • In this paper, A generator of existing vertical type wind turbine system is connected to bevel gear. But, the generator of proposed wind turbine system is connected to Hydraulic torque converter. In case of the proposed wind turbine system, is possible to make torque transmission long distance, set up generator somewhere in between the tower or the ground as well as, nacelle weight can be greatly down. Lightweight of nacelle exactly wind direction tracking can be easily also, cost down of established frame structure and generator setting, maintenance, easy and improvement of system stability.

A Mathematical Model on the Absorption Rate of Carbon-Dioxide in Mixed Gas During the Transient State of Rotary Type Absorbers (과도상태의 회전형 흡수기에서 혼합기체 중 이산화탄소 흡수량 계산 모델)

  • Paik, Hyun-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.12
    • /
    • pp.1729-1737
    • /
    • 2002
  • A mathematical model for the prediction of carbon-dioxide absorption rate during the transient state of rotary type absorber is developed. The rotary type absorber operates using a fast rotating porous structure and clean water. The model for the transient state rotary type absorbers is based on the steady state model of packed tower absorber. The paper manipulates the operating data of an arbitrary quasi-steady state condition of rotary type absorber for the determination of the coefficients involved in the model developed. The prediction accuracy is evaluated from the measured data of rotary type absorber operated under fast transient state. The measured data include the mole fraction of carbon dioxide in mixed gas and the pressure of absorber. The relative error in carbon dioxide prediction is estimated to be 20% at maximum. The model is successfully applied for the prediction of the behavior of a closed cycle diesel engine.

An Evaluation on Electrical Shock and Ignition Hazards in Metallic Structures Acting Receiving Antennas of Radio-frequency Radiation (고주파 방사에 대한 수신 안테나로 작용하는 구조물에서의 전격 및 점화 위험성 평가)

  • Choi, Sang-Won;Lee, Hyung-Soo;Lee, Gwan-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2280-2283
    • /
    • 1999
  • Close to high power radio/radar transmitters, there is a possibility that electrical sparks may occur at discontinuities in metallic structures. If these structures are in an area where flammable mixtures are present, there is a danger that fire or explosion may happen by these sparks. Voltage may be induced on these metallic structures by the radio-frequency transmitter. In this case, a person who comes into contact with these structure may be undergone a severe electrical shock. In this paper, assessment of the these hazards was investigated through experimental and evaluation for actual tower cranes near AM radio transmitters.

  • PDF

Vibration analysis of two span continuous special orthotropic plates with elastic intermediate support (탄성지지된 2경간 연속 철근콘크리트 슬래브교와 샌드위치 패널슬래브의 진동해석)

  • 김덕현;김경진;이세진;이원석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.341-348
    • /
    • 1998
  • A method of calculating the natural frequency corresponding to the first mode of vibration of beams and tower structures, with irregular cross sections and with arbitrary boundary conditions was developed and reported by Kim, D. H. in 1974. In this paper, the result of application of this method to the subject problem is presented. The structure considered for this report is two span continuous special orthotropic plates with elastic intermediate support. The use of elastic support as one of the passive control means is common. Any method may be used to obtain the deflection influence surfaces needed for this vibration analysis. Finite difference method is used for this purposa in this paper. The influence of the modulus of the foundation, and $D_{ij}$ stiffnesses on the natural frequency is thoroughly studied.

  • PDF

15 Park Row New York City - 120 Years Later, Still Relevant in Contextualism and Sustainability

  • Karahan, Beyhan
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.1
    • /
    • pp.61-70
    • /
    • 2020
  • After the 1884 Home Insurance building in Chicago and 1889 Tower building in New York, 15 Park Row became the tallest building in the USA in 1899 and it held this record for nine years. Completed just before the arrival of the 20th century, this building deserves to be recognized for the sophistication of its architecture with respect to contextual understanding of the 19th century historic texture in Lower Manhattan, its uniquely economical floor plans, and its use of natural ventilation and daylight. The compositional techniques using the proportional analysis of its context reflect the highest level of architectural education of its time by its architect Robert H. Robinson. In addition, it also offers a unique glimpse to the state-of-the-art technology of its time regarding its structure, its use of movement systems that was capable of serving 4000 users.

Design of Spot Weld Based on the Durability Influence Index and the DOE Analysis (점용접부 내구 영향도 지수와 실험 계획법을 이용한 자동차 부품 점용접 설계)

  • Choi, Noo-Ri;Ju, Byeong-Hyeon;Park, Jung-Min;Eom, Jae-Sung;Byun, Hyung-Bai;Kim, Dong-Seok;Lee, Byung-Chai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.9 s.252
    • /
    • pp.1142-1147
    • /
    • 2006
  • A practical method for reducing the number of spot welds in automotive structures considering fatigue crack initiation life is suggested. At first, an influence index for the durability and the fatigue life of a spot weld itself is defined and then taken as the main effect of the DOE analysis. Spot welds that can be removed without serious reduction of durability through numerical experiments are selected by the results of DOE. The proposed method was applied to the shock tower and LCA(lower control arm) structure of a vehicle, which are important components in durability-related point of view.

Vibration Monitoring of a 1kW Small Wind Turbine Generator (1kW소형 풍력발전기의 진동 모니터링)

  • Kim, Seock-Hyun;Nam, Y.S.;Yoo, N.S.;Kim, Yun-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.308-311
    • /
    • 2006
  • A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

  • PDF

Seismic analysis and modeling of isolated elevated liquid storage tanks

  • Seleemah, Ayman A.;El-Sharkawy, Mohamed
    • Earthquakes and Structures
    • /
    • v.2 no.4
    • /
    • pp.397-412
    • /
    • 2011
  • In this paper, the seismic response of elevated broad and slender liquid storage tanks isolated by elastomeric or sliding bearings was investigated. The accuracy of predictions of SAP2000 vs. 3D-BASIS-ME programs was examined. A comparative study of the performance of base isolated tanks when isolation bearings are placed at the top or at the bottom of the supporting tower structure was conducted. It was found that base isolation is quite effective in reducing the earthquake response of elevated liquid storage tanks in which high reductions of base shear and shaft displacement were achieved. Modeling the isolated tanks in SAP2000 was very successful in producing results that are nearly identical to those of program 3D-BASIS-ME. Placing the isolators at the top of the shaft in elevated tanks proved to be much better than placing them at the bottom.