• 제목/요약/키워드: Tower Ground

검색결과 184건 처리시간 0.022초

Electromyography 기법을 이용한 육상 크라우칭 스타트의 하체 근 동원 비교분석 (Electromyography Analysis of Muscle Activities of tower limb for Crouching Start Technique)

  • 신성휴;박기자
    • 한국운동역학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 2003
  • The purposes of this study were to analyze the muscle activities and the characteristics of muscle recruting patterns of lower limb for crouching start technique using four elite splint. The EMG technique was used to record muscle activities of both right and left sides of retus femoris, vastus medialis, biceps femoris, and gastrocnemius. Eight surface electrodes were placed on the surface of the selected muscles and one ground electrode was also attached on the back of neck(C7). One video camera was also used to record the crouching start motion to define 6 events and 5 phases for further analysis. The raw EMG data were filtered with band pass filter(10-350) to remove artifacts and then low pass filtered(4Hz) to find the linear envelope which resemble muscle tension curve. This filter EMG data were normalized to MVIC for the purpose of comparison between right and left sides muscle. The results of this study were as follows. All four subjects showed that vastus medialis muscle activity was comparatively higher than those of retus femoris, biceps femoris, gastrocnemius. And left side of muscle activity was comparatively higher than right side of muscle activity. Therefore, when the subjects starting out crouching start position, we recognized that the muscle of lower limb showed interaction effect by each muscle.

Structural Design of High-Rise Concrete Condominium with Wall Dampers for Vibration Control

  • Tsushi, Takumi;Ogura, Fumitaka;Uekusa, Masahiro;Kake, Satoshi;Tsuchihashi, Toru;Yasuda, Masaharu;Furuta, Takuya
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.201-209
    • /
    • 2019
  • This paper presents a structural design of the "(Tentative Name) Toranomon Hills Residential Tower" which is currently under construction in Tokyo. The building is a reinforced concrete high-rise residential complex building with 54 stories above ground, 4 basement levels, and a building height of about 220 m. It is a requirement to provide the highest grade of residence in Japan, and in terms of the structural design, it is required to provide wide and comfortable spaces with high seismic performance. These requirements are satisfied by providing a total of 774 vibration control walls of two types. Also, to further improve the structural performance, steel fibers at the rate of 1.0vol% are provided in the ultra-high strength concrete used in the column members.

Transmission Lines Rights-of-Way Mapping Using a Low-cost Drone Photogrammetry

  • Oh, Jae Hong;Lee, Chang No
    • 한국측량학회지
    • /
    • 제37권2호
    • /
    • pp.63-70
    • /
    • 2019
  • Electric transmission towers are facilities to transport electrical power from a plant to an electrical substation. The towers are connected using wires considering the wire tension and the clearance from the ground or nearby objects. The wires are installed on a rights-of-way that is a strip of land used by electrical utilities to maintain the transmission line facilities. Trees and plants around transmission lines must be managed to keep the operation of these lines safe and reliable. This study proposed the use of a low-cost drone photogrammetry for the transmission line rights-of-way mapping. Aerial photogrammetry is carried out to generate a dense point cloud around the transmission lines from which a DSM (Digital Surface Model) and DTM (Digital Terrain Model) are created. The lines and nearby objects are separated using nDSM (normalized Digital Surface Model) and the noises are suppressed in the multiple image space for the geospatial analysis. The experimental result with drone images over two spans of transmission lines on a mountain area showed that the proposed method successfully generate the rights-of-way map with hazard nearby objects.

Seismic responses of hyperbolic cooling towers under horizontal and vertical earthquake

  • Zhang, Jun-Feng;Wang, Yuan-Hao;Li, Jie;Zhao, Lin
    • Earthquakes and Structures
    • /
    • 제20권4호
    • /
    • pp.405-415
    • /
    • 2021
  • Following the dynamic property analysis and elaboration, linear response spectrum analysis (RSA) and response history analysis (RHA) were conducted on a representative hyperbolic cooling towers (HCT) in present study. The seismic responses in tower shell were illustrated in detail, including the internal force amplitude, modal contribution, influence from damping ratio, comparison of results got from RSA and RHA and especially the latitude distributions of internal forces. The results show that the eigenmodes could be classified in a new method into four types according to their mode shapes and only the lateral bending modes and vertical stretching modes are meaningful for horizontal and vertical earthquake correspondingly. The bending modes and seismic deformation display the same feature which is global lateral bending accompanied by minute circular flow displacement of section. This feature also decides the latitude distributions of internal forces as sine or cosine. Moreover, the following method is also proposed for approximate estimation of internal force amplitudes without time-consuming response history analysis: getting the response spectrums of the selected ground accelerations and then comparing values of response spectrums at the natural period of first lateral bending mode because it is always prime dominant for horizontal seismic responses.

Potential wind power generation at Khon Kaen, Thailand

  • Supachai, Polnumtiang;Kiatfa, Tangchaichit
    • Wind and Structures
    • /
    • 제35권6호
    • /
    • pp.385-394
    • /
    • 2022
  • The energy demand of the world is increasing rapidly, mainly using fossil energy, which causes environmental damage. The wind is free and clean energy to solve the environmental problems. Thailand is one of the developing nations, and the majority of its energy is obtained from petroleum, natural gas and coal. The objective of this study is to test the characteristics of wind energy at Khon Kaen in Thailand. The wind measurement tools, the 3-cup anemometers to measure wind speed, and wind vanes to measure wind direction, were mounted on a wind tower mast to record wind data at the heights of 60, 90 and 120 meters above ground level (AGL) for 5 years between January 2012 and December 2016. The results show that the annual mean wind speeds were 3.79, 4.32 and 4.66 m/s, respectively. The highest mean wind speeds occurred in June, August and December, in order, and the lowest occurred in September. The majority of prevailing wind directions were from the North-East and South-West directions. The average annual wind shear coefficient was 0.297. Furthermore, five wind turbines with rated power from 0.85 to 4.5 MW were selected to estimate the wind energy output and it was found that the maximum AEP and CF were achieved from the low cut-in speed and high hub-height wind turbines. This important information will help to develop wind energy applications, such as the plan to produce electricity and the calculation of the wind load that affects tall and large structures.

고유진동수 기반 석션기초의 지반구속효과 분석 (Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement)

  • 유무성;이준신;이종화;서윤호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

MODIS 위성자료를 이용한 Modified Satellite-Based Priestley-Taylor (MS-PT)의 적용 및 실제 증발산 평가 (Assessment of actual evapotranspiration using modified satellite-based priestley-taylor algorithm using MODIS products)

  • 백종진;박종민;최민하
    • 한국수자원학회논문집
    • /
    • 제49권11호
    • /
    • pp.903-912
    • /
    • 2016
  • 증발산은 물수지 및 수문순환의 체계를 파악하기 위한 중요한 인자로서 이에 대한 정확한 이해 및 산정이 필요하다. 국내외에서 증발산에 대한 많은 연구들이 수행되었으나, 지점자료만을 이용하여 산정한 증발산은 시 공간적인 변동성을 파악하는데 제약이 발생한다. 이에 따라, 물리식을 기반으로 하여 인공위성에서 산정된 수문기상인자를 활용하여 증발산량의 시 공간적인 표현에 대한 연구가 발전하게 되었다. 그러나 기존에 활용되고 있는 방법들은 상대적으로 많은 입력 자료가 요구된다. 본 연구에서는 MOderate-Resolution Imaging Spectroradiometer (MODIS) 산출물을 이용하여 순복사에너지를 산정하였으며, 기존에 활용된 인공위성 기반 증발산 알고리즘에 비해 상대적으로 적은 입력 자료를 이용하는 Modified Satellite-Based Priestley-Taylor (MS-PT) 알고리즘을 적용하여 실제증발산을 산정하였다. 또한, MODIS 산출물로부터 계산된 순복사에너지와 실제증발산의 정확성을 확인하기 위하여, 청미천과 설마천의 플럭스 타워에서 관측된 자료와 비교 검증을 실시하였다. 전반적으로 MODIS 자료를 이용하여 산정된 순복사에너지와 실제증발산 값이 두 플럭스 타워에서 관측된 순복사에너지와 실제증발산이 높은 상관성을 나타내는 것을 확인할 수 있었다. 특히. 전체 모의기간 동안 인공위성 자료를 이용하여 산정된 실제증발산의 평균 결정계수는 청미천에서 0.77(0.72-0.81), 설마천에서 0.70(0.67-0.78)로 나타났다. 그러나, 청미천에 비해 설마천에서의 실제증발산 값이 과대산정되는 것을 확인 할 수 있었다. 이러한 이유는 식생에 대한 영향 및 MODIS로부터 산정된 복사에너지에서의 오차로 인해 발생한 것으로 판단된다.

헬리콥터 주로터 블레이드의 동적밸런싱 시험에 대한 데이터베이스 설계 및 적용 (Design and Application of Database System for Dynamic Balancing Test of Helicopter Main Rotor Blade)

  • 윤병일;백승길;송근웅;김덕관
    • 한국항공우주학회지
    • /
    • 제47권8호
    • /
    • pp.582-589
    • /
    • 2019
  • 헬리콥터 주로터 블레이드의 동적 밸런싱 시험은 헬리콥터의 비행시험 전 각 블레이드의 트랙과 피치로드 하중을 동일한 수준으로 조절하기 위해 수행되는 지상회전시험이다. 이러한 동적밸런싱 시험의 목적은 블레이드 간 특성차이로 인해 나타나는 주로터 시스템 진동을 감소시키기 위함이다. 고흥 항공센터의 훨타워 시험설비에서는 오랜 기간에 걸쳐 수리온 주로터 블레이드에 대한 동적밸런싱 시험을 수행하고 데이터를 축적해 왔다. 이에 데이터양이 점차 방대해짐에 따라 시험결과를 효율적으로 관리하기 위한 데이터베이스 프로그램의 개발의 필요성이 제기되어 왔다. 본 연구에서는 훨타워 시험설비에서 수행한 동적밸런싱 시험결과를 바탕으로 구축한 데이터베이스 시스템에 대해 기술하였다. 본 연구에서 구현된 데이터베이스 시스템은 동적밸런싱 시험 결과를 각 정보별로 논리적으로 모델링하고 각각의 데이터가 상호 관계를 이룰 수 있도록 연결하여 관계형 구조를 이루도록 설계되었다. 아울러 본 논문을 통해 기 설계된 데이터베이스 시스템이 동적밸런싱 시험 결과의 축적과 시험 결과 분석에 효과적으로 활용될 수 있음을 보였다.

2011년 5월 관측된 고농도 황사 사례 연구 (A Case Study of the Heavy Asian Dust Observed in May 2011)

  • 안보영;임병환
    • 한국지구과학회지
    • /
    • 제43권3호
    • /
    • pp.386-404
    • /
    • 2022
  • 2011년 4월 29일부터 30일까지 몽골에서 발원한 황사의 영향으로 우리나라는 4일간 전국적으로 고농도의 황사가 관측되었다. 본 연구는 몽골의 황사발원지에서 황사 발생 시 기상 조건과 고농도 황사 사례의 원인 및 특성을 알아보기 위한 것으로, 황사 일기도 자료, 황사감시기상탑 자료, 위성 자료, 후방공기궤적 자료, 관측자료(PM10 및 광학입자 계수기 자료), ECMWF 재분석 자료를 이용하였다. 분석 결과, 종관 분석에서는 몽골 중부지역에 등압선의 간격이 조밀하게 분포하고 기압경도력이 강해지면서 강풍에 의해 황사가 발원하였다. 황사 발원과 기상 조건의 관계에서 황사 발원 직전에는 10℃ 이상으로 비교적 높은 기온을 나타내다 황사 발원과 동시에 급감하였으며, 상대습도는 약 40% 이하의 낮은 값을 지속적으로 나타내다 황사 발원 후에는 50% 이상으로 급격히 높아지며 황사의 발생이 줄어드는 경향을 보였다. COMS에서 관측된 황사지수는 황사발원지에서는 25 이상을 나타내면서 고농도의 황사가 탐지되었고, 실황에서 목측으로 관측된 지점과 일치하였다. 72시간 후방공기궤적에서는 모두 북서 기류가 한반도로 유입되었고, 5월 2일 흑산도에서는 PM10의 시간평균농도가 1,025 ㎍ m-3으로 최고 농도를 보였다. 특히 운동학적 연직 분석에서, 상층에서 발달한 기압골과 저기압성 소용돌이도에 의해 지상 저기압이 강화되고 동시에 상승 기류의 발달이 고농도의 황사 발생에 큰 역할을 한 것으로 판단된다.

국내 종합병원의 형태 유형 변화에 관한 연구 (A Study on the Change of Form Type in General Hospital)

  • 김은석;양내원
    • 한국실내디자인학회논문집
    • /
    • 제23권6호
    • /
    • pp.195-203
    • /
    • 2014
  • This study selects factors affecting form type of hospital architecture by considering studies and references on hospital architecture type in korea and other countries in general. Also this study classifies general hospitals chronologically and analyzes type change of general hospitals in relation with periodic change of healthcare environment. Through this, this study aims to analyze chronological change of general hospitals' form type and provide the current of hospital architecture's general type. The form type classification of this study is classification according to the form of ward, classification according to the relationship between ward and D.T.D(Diagnostic and Treatment department), classification according to the relationship between O.P.D(Out Patient department) and D.T.D, classification according to the rate of centralization, classification according to the circulation system. The form type of ward changed from plate type to tower type, and the circulation system of ward changed from middle corridor to double corridor, the number of Team Nursing chaged from 1 to 2 in 1990. On the other hand the chage of others classifications took place from 1990' to 2010'. It is judged that this overall change is appeared by a change from an inpatien-oriented system to an outpatient-oriented system followed by an increase in number of outpatients, an increase in amenities in ground floor and adoption of healing environment for patients and visitors.