• Title/Summary/Keyword: Total system and Sub system

Search Result 678, Processing Time 0.032 seconds

INCREASING TREND OF ANGSTROM EXPONENT OVER EAST ASIAN WATERS OBSERVED IN 1998-2005 SEAWIFS DATA SET

  • Fukushima, Hajime;Liping, Li;Takeno, Keisuke
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.57-60
    • /
    • 2007
  • Monthly mean data of ${\AA}ngstr{\ddot{o}}m$ exponent and Aerosol optical thickness (AOT) from Sea-viewing Wide Field-of-view Sensor (SeaWiFS) measurements over the East Asian waters were analyzed. Increasing trend of the satellite-derived ${\AA}ngstr{\ddot{o}}m$ exponent from 1998 to 2004 was found while AOT mean was observed stable during the same period. The trend of ${\AA}ngstr{\ddot{o}}m$ exponent is then interpreted as increase in fraction of small aerosol particles to give quantitative estimates on the variability of aerosols. The mean increase is evaluated to be $4{\sim}5%$ over the 7-year period in terms of the contribution of small particles to the total AOT, or sub-micron fraction (SMF). Possibilities of the observed trend arising from the sensor calibration or algorithm performance are carefully checked, which confirm our belief that this observed trend is rather a real fact than an artifact due to data processing. Another time series of SMF data (2000-2005) estimated from the fine-mode fraction (FMF) of Moderate Resolution Imaging Spectroradiometer (MODIS) supports this observation yet with different calibration system and retrieval algorithms.

  • PDF

A Study on the Analysis of College Students' Learning Process : Based on the surveys in K-College (전문대학생의 학습과정 분석에 관한 연구 : K-전문대학을 중심으로)

  • Kim, Soo hyun;Bae, Yu Na;Lee, Jin-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.547-557
    • /
    • 2017
  • This study analyzed the differences depending on gender differences, the years for graduation, college majors, and grades by the level of students' learning process about the student engagement of college students. Subjects were 684 students who responded to a student engagement survey questionnaire among the students attending the regular curriculum at the K-college located in Geoje-si. For measurement, the college students' learning process analysis scale was modified and supplemented prior to use. Frequency analysis was adopted to search individual backgrounds of college students. One-way ANOVA and Post-hoc test were conducted in order to find differences according to gender differences, the years for graduation, college majors, and grades by the level of learning process. The study results are as follows. First, the college students' learning process on gender had significant differences in involvement in and out of instruction, teaching-learning outcomes, and college facility system and service. Second, the college students' learning process according to the years for graduation had significant differences in involvement in and out of instruction, class satisfaction, and college facility system and service. Third, the college students' learning process according to major differences had significant differences in involvement in and out of instruction, study interactions, academic achievement, and college facility system and service. Fourth, the college students' learning process according to grades had significant differences in total sub-components (involvement in and out of instruction, class satisfaction, study interactions, academic achievement, and college facility system and service). Lastly, the study discussions and implications are described.

The Estimation of PM2.5 Emissions and Their Contribution Analysis by Source Categories in Korea (국내 배출원별 PM2.5 배출량 산정 및 배출 기여도 분석)

  • Jin, Hyung-Ah;Lee, Ju-Hyoung;Lee, Kyung-Mi;Lee, Hyang-Kyeong;Kim, Bo-Eun;Lee, Dong-Won;Hong, You-Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.2
    • /
    • pp.211-221
    • /
    • 2012
  • The Ministry of Environment will enforce air quality standards for $PM_{2.5}$ in 2015 because it affects human health as well as climate change and brings about other adverse effects. Until recently, even though a number of researches have reported $PM_{2.5}$ emissions according to sources, they have not precisely considered the emission factors correspondent to each source for emission estimation. For the sake of establishing $PM_{2.5}$ emission inventories, this study was undertaken using activity data of each source taken from CAPSS (Clean Air Policy Support System) multiplied by each emission factor of U.S. EPA Speciate or EEA CORINAIR. The 2008's total annual $PM_{2.5}$ emission (73.971 ton/yr) can be apportioned into five sources, such as fuel combustion facilities (62.2%), mobiles (33.8%), production processes (3.2%), fires (0.4%), and waste treatments (0.3%). The results show that fuel combustion facilities and mobiles are the predominant sources of $PM_{2.5}$, and they should be taken into great account in establishing $PM_{2.5}$ standards. In addition, it is necessary and urgent to develop effective measures for reduction of $PM_{2.5}$ emissions from those two main sources as well.

Biological conversion of CO2 to CH4 in anaerobic fixed bed reactor under continuous operation (혐기성 고정층 생물반응기의 연속운전을 통한 이산화탄소의 메탄전환)

  • Kim, Jaehyung;Koo, Hyemin;Chang, Wonseok;Pak, Daewon
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.347-354
    • /
    • 2013
  • This study was carried out to examine different mole ratio of $H_2/CO_2$ and EBCT using the continuous system in the lab scale throughout biological methods with accumulated hydrogenotrophic methanogen that can convert $CO_2$ to $CH_4$. The experimental-based results with various gas mixtures of mole ratio of 4:1($H_2/CO_2$) and 5:1($H_2/CO_2$), $H_2$ was converted more than 99% conversion rate. In case of $CO_2$, 4:1($H_2/CO_2$) and 5:1($H_2/CO_2$) were $74.45{\pm}0.33%$, $95.8{\pm}10.7%$, respectively, in addition, the study was confirmed that the amount of $H_2$ was more needed than stoichiometric equations, where approach methods are empirical versus theoretical frameworks, for converting total $CO_2$. As such, we have noticed that $H_2$ was used for energy source of hydrogenotrophic methanogen for maintaining life. Regarding the results of the ratio of treatment by retention time, limitation of treatment capacity showed that $H_2$(99.9%) and $CO_2$(96.23%) at EBCT 3.3 hrs indicated stable conversion ratio, as well as appeared that methane production rate and $CO_2$ fixation rate were investigated $1.15{\pm}0.02m^3{\cdot}m^{-3}{\cdot}day^{-1}$ and $2.01{\pm}0.04kg{\cdot}m^{-3}{\cdot}day^{-1}$, respectively.

High Efficiency Active Phased Array Antenna Based on Substrate Integrated Waveguide (기판집적 도파관(SIW)을 기반으로 하는 고효율 능동 위상 배열안테나)

  • Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.227-247
    • /
    • 2015
  • An X-band $8{\times}16$ dual-polarized active phased array antenna system has been implemented based on the substrate integrated waveguide(SIW) technology having low propagation loss, complete EM shielding, and high power handling characteristics. Compared with the microstrip case, 1 dB less is the measured insertion loss(0.65 dB) of the 16-way SIW power distribution network and doubled(3 dB improved) is the measured radiation efficiency(73 %) of the SIW sub-array($1{\times}16$) antenna element. These significant improvements of the power division loss and the radiation efficiency using the SIW, save more than 30 % of the total power consumption, in the active phased array antenna systems, through substantial reduction of the maximum output power(P1 dB) of the high power amplifiers. Using the X-band $8{\times}16$ dual-polarized active phased array antenna system fabricated by the SIW technology, the main radiation beam has been steered by 0, 5, 9, and 18 degrees in the accuracy of 2 degree maximum deviation by simply generating the theoretical control vectors. Performing thermal cycle and vacuum tests, we have found that the SIW array antenna system be eligible for the space environment qualification. We expect that the high efficiency SIW array antenna system be very effective for high performance radar systems, massive MIMO for 5G mobile systems, and various millimeter-wave systems(60 GHz WPAN, 77 GHz automotive radars, high speed digital transmission systems).

A Study on CO2 Emissions to Establish a LCI DB at the Disuse Stage (폐기단계에서 LCI DB구축을 위한 CO2 발생량에 관한 연구)

  • Choi, Doo-Sung;Park, Jin Jong;Chun, Hung Chan
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.103-110
    • /
    • 2013
  • This study aims to calculate the $CO_2$ emissions by the properties of construction waste to establish a LCI DB of construction waste generated at the disuse stage. The $CO_2$ emissions from apartment houses was calculated by calculating the energy consumptions by treatment steps to calculate the $CO_2$ emissions by the treatment steps of construction waste. As a result of analyzing the $CO_2$ emissions from a total of 27 complexes, maximum 46,791g-$CO_2/m^2$, minimum 34,893g-$CO_2/m^2$ and average 38,713g-$CO_2/m^2$ were generated, and were varied by the quantity of construction waste in general, but were affected by the transportation distance in case of transportation steps as well. As a result of analyzing the $CO_2$ emissions by the properties of construction waste, average 19,815.50g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage in case of construction wastes, and 1.72g-$CO_2/m^2$ was generated, the lowest, during reclamation. In case of combustible waste, average 11,495.63g-$CO_2/m^2$ was generated, the highest, from the example complex during incineration of wastes, and 21.48g-$CO_2/m^2$ was generated, the lowest, at the waste transportation stage. In case of noncombustible waste, average 522.43g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage, and 1.07g-$CO_2/m^2$ was generated, the lowest, at the transportation stage. In case of other construction wastes, average 645.42g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage, and 47.38g-$CO_2/m^2$ was generated, the lowest, at the middle treatment stage.

Durability Evaluation of Cement Concrete Using Ferrosilicon Industrial Byproduct (페로실리콘 산업부산물 활용 시멘트 콘크리트의 내구성능 평가)

  • Chang-Young Kim;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.89-96
    • /
    • 2023
  • In this paper, a ferrosilicon by-product was evaluated to confirm the feasibility of recycling it as supplementary cementitious material of ordinary Portland cement in concrete. Three different levels of replacement ratio (10 %, 20 % and 30 % of total binder) were applied to find which is the most beneficial to be used as a binder. Ferrosilicon concrete was initially assessed at setting time and compressive strength. Durability was evaluated by the resistance to chloride penetration test(RCPT) and alkali-silica reaction(ASR) with a comparison to silica fume concrete due to their similarity in chemical composition. The porosimetry and X-ray diffraction analysis along with energy dispersive X-ray spectroscopy give information on the microstructural characteristics of the ferrosilicon concrete. It was found that 10 % ferrosilicon concrete has higher strength while 20 %, 30 % have lower strength than OPC concrete. However, chemical resistance to chloride attack is higher when replacement is increased. Compared to silica fume, the durability of ferrosilicon might be less efficient however, it is obviously beneficial than OPC. High SiO2 content in ferrosilicon results in producing more C-S-H gel which could make denser pore structure. Most of the risk of alkali silica reaction to silicate binders through length change tests was less than 0.2 %, and both mortar using ferrosilicon and silica fume showed better resistance to alkali silica reaction as the substitution rate increased.Reuse of industrial waste rather than producing highly refined additives might reduce environmental load during manufacture and save costs.

Techno-economic Analysis and Environmental Impact Assessment of a Green Ammonia Synthesis Process Under Various Ammonia Liquefaction Scenarios (암모니아 액화 시나리오에 따른 그린암모니아 합성 공정의 경제성 및 환경 영향도 평가)

  • Gunyoung Kim;Yinseo Song;Boram Gu;Kiho Park
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.163-172
    • /
    • 2024
  • In this study, two different scenarios for ammonia liquefaction in the green ammonia manufacturing process were proposed, and the economic-feasibility and environmental impact of each scenario were analyzed. The two liquefaction processes involved gas-liquid separation before cooling at high pressure (high pressure cooling process) or after decompression without the gas-liquid separation (low pressure cooling process). The high-pressure cooling process requires higher capital costs due to the required installation of separation units and heat exchangers, but it offers relatively lower total utility costs of 91.03 $/hr and a reduced duty of 2.81 Gcal/hr. In contrast, although the low-pressure cooling process is simpler and cost-effective, it may encounter operational instability due to rapid pressure drops in the system. Environmental impact assessment revealed that the high-pressure cooling process is more environmentally friendly than the low-pressure cooling process, with an emission factor of 0.83 tCO2eq less than the low-pressure cooling process, calculated based on power usage. Consequently, the outcomes of this study provide relevant scenario and a database for green ammonia synthesis process adaptable to various process conditions.

An Economic Value for the First Precipitation Event during Changma Period (장마철 첫 강수의 경제적 가치)

  • Seo, Kyong-Hwan;Choi, Jin-Ho
    • Atmosphere
    • /
    • v.32 no.1
    • /
    • pp.61-70
    • /
    • 2022
  • This study evaluates the economic values for the several first precipitation events during Changma period. The selected three years are 2015, 2019, and 2020, where average precipitation amounts across the 58 Korean stations are 12.8, 20.1 and 13.3 mm, respectively. The four categories are used to assess the values including air quality improvement, water resource acquisition/accumulation, drought mitigation, and forest fire prevention/recovery. Economic values for these three years are estimated 50~150 billion won. Among the four factors considered, the effect of air quality improvement is most highly valued, amounting to 70 to 90% of the total economic values. Wet decomposition of air pollution (PM10, NO2, CO, and SO2) is the primary reason. The next valuable element is water resource acquisition, which is estimated 9~15 billion won. Effects of drought mitigation and fire prevention are deemed relatively small. This study is the first to estimate the value of the precipitation events during Changma onset. An analysis for more Changma years will be performed to achieve a more reliable estimate.

A by-pass rainwater penetration sewer system for urban flooding mitigation (도시침수 저감을 위한 by-pass 빗물침투성 우수관거)

  • Lee, Bum-Sub;Ko, Keon-Ho;Kang, Ho-Yeong;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.9
    • /
    • pp.799-807
    • /
    • 2016
  • The aim of this study is to determine and propose the by-pass rainwater sewer system in order to reduce the urban floodplain from the locality heavy rain every year during the dry season and the sinkholes in the city as well as the shortage of groundwaters due to extreme hot weather condition and urban heat island phenomenon. Heavy rain occurs more than the years of heavy rainfall probability, comparison between the place where uses the existing pipes and connect the sewer system with by-pass rain permeability and without expanding sewer pipe replacement at intersection of Gangnam station 3.07 ha at Gangnam-gu, Seoul Metropolitan area, it indicates that average of 27 million KRW (44%) maintenance cost savings and maintain existing sewer system without any other countermeasures. For the city flooded reduction, by-pass rainwater permeable rainwater pipe multiplying the probability the number of years during summer season and increase the water flow capacity during spring and fall when a small amount of rain that, it also contribute to the total amount of underground water secured through the by-pass penetration.