• Title/Summary/Keyword: Total suspended particulate (TSP)

Search Result 67, Processing Time 0.025 seconds

Ionic composition comparison of atmospheric aerosols at coastal and mountainous sites of jeju island (제주도 해안과 산간 지역 대기 에어러솔의 이온조성 비교)

  • Hong, Sang-Bum;Jung, Duk-Sang;Lee, Soon-Bong;Lee, Dong-Eun;Shin, Seung-Hee;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.24-37
    • /
    • 2011
  • The ionic compositions of atmospheric aerosols were investigated and characterized in coastal and mountainous sites of Jeju Island, which were Gosan and Mt. Halla-1100 sites respectively. It was found that the concentrations of nss-$SO_4^{2-}$ (non-sea salt sulfate) and $NH_4^+$ at two measurement sites were almost similar and they showed high concentrations in June at the same time. The concentration of soil-originated nss-$Ca^{2+}$ (non-sea salt calcium) was generally associated with that of anthropogenic $NO_3^-$ and its concentration was increased during spring season. From the comparison of time-series variation and regression analysis of ionic species between two measurement sites, TSP (total suspended particulate) in Gosan site was directly influenced by sea salt particles and the concentration levels of nss-$SO_4^{2-}$, $NH_4^+$, nss-$Ca^{2+}$, $K^+$, and $NO_3^-$ were mainly related with long-range transported air pollutants rather than local pollution sources.

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

Emission Characteristics of Air Pollutants and Black Carbon from Wood-pellet Stove and Boiler (목재 펠릿 난로와 보일러 사용에 의한 대기오염물질과 블랙카본의 배출 특성)

  • Park, Sung Kyu;Lyu, Kun Jung;Kim, Daekeun;Kim, Dong Young;Jang, Young Kee;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • This study was carried out simulating domestic utilization conditions of a wood pellet stove and a wood pellet boiler in order to determine emission factors (EFs) of macro-pollutants, i.e., carbon monoxide, nitrogen oxides, sulfur oxides, ammonia, particulate matters (total suspended particulate, $PM_{10}$, $PM_{2.5}$, black carbon) and trace pollutants (i.e., ten different volatile organic compounds). The composite pollutants EFs for the pellet stove were: for TSP 4.58 g/kg, for $PM_{10}$ 3.35 g/kg, for $PM_{2.5}$ 2.48 g/kg, CO 119.23 g/kg, NO 14.40 g/kg, $SO_2$ 0.17 g/kg, TVOC 37.73 g/kg, $NH_3$ 0.02 g/kg and emissions were similar to the pellet boiler appliance: for TSP 4.73 g/kg, for $PM_{10}$ 3.41 g/kg, for $PM_{2.5}$ 2.63 g/kg, CO 161.51 g/kg, NO 13.67 g/kg, $SO_2$ 0.19 g/kg, TVOC 45.22 g/kg, $NH_3$ 0.02 g/kg.

Emission Characteristics of Air Pollutants and Black Carbon from Wood Stove and Boiler (화목 난로와 보일러 사용에 의한 대기오염물질과 블랙카본의 배출 특성)

  • Park, Sung Kyu;Choi, Sang Jin;Kim, Dae keun;Kim, Dong Young;Jang, Young Kee;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.6 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Manually fed firewood burning appliances, i.e., stove and boiler, were tested in order to determine emission factors (EFs) of macro-pollutants, i.e., carbon monoxide, nitrogen oxides, sulfur oxides, ammonia, particulate matters (total suspended particulate, $PM_{10}$, $PM_{2.5}$, black carbon) and trace pollutants (i.e., ten different volatile organic compounds). The composite pollutants EFs for the wood stove were: for TSP 15.45 g/kg, for $PM_{10}$ 6.53 g/kg, $PM_{2.5}$ 4.16 g/kg, CO 175.49 g/kg, NO 1.58 g/kg, $SO_2$ 0.15 g/kg, TVOC 48.02 g/kg, $NH_3$ 0.02 g/kg and emissions were similar to the wood boiler appliance: for TSP 12.23 g/kg, for $PM_{10}$ 5.84 g/kg, $PM_{2.5}$ 3.66 g/kg, CO 146.74 g/kg, NO 1.42 g/kg, $SO_2$ 0.15 g/kg, TVOC 47.78 g/kg, $NH_3$ 0.01 g/kg.

Dust Collecting Efficiency Using Cyclone Deduster in Weanned Piglet Building (자돈사에서의 사이크론 먼지제거기의 집진효율 분석)

  • 최희철;이덕수;권두중;강희설;유용희;송준익;성환후;김형호;천상석
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.19-26
    • /
    • 2003
  • This study was carried out to investigate the collecting efficiency of cyclone deduster installed in weaned piglet building in third weeks of age. There are two peaks of high level of dust concentration in piglet house at the time of 09:00~10:00(5,322$\mu g/m^3$) and 19:00~20:00(6,763$\mu g/m^3$), but the peaks of dust concentration in the building used cyclone deduster was decreased to 3,614.8 and 2,229.5$\mu g/m^3$, respectively. Collecting efficiency of total suspended particulate(TSP), particulate matter less than 10$\mu\textrm{m}$(PM 10) and particulate matter less than 2.5$\mu\textrm{m}$(PM 2.5) in weaned piglet building used in cyclone deduster was 38.3%, 32.5, 21.8, respectively. Aerial dust in weaned piglet building by number basis in the range of 0.745~1.08$\mu\textrm{m}$ was 53.5%. But dust distribution over 10$\mu\textrm{m}$ in volume basis was 82.8% and 86.2%. Crude protein of dust was 25.9~32.7%, and it was higher than feed crude protein(22.0%). Heavy metal concentration of dust was also high level compare to that of feed.

  • PDF

Analysis of Growth Indicators of Applied Plants by AHU(Air Handling Unit)-linking with Artificial Soil-based Vegetation Bio-filters (인공토양기반 식생바이오필터의 AHU(Air Handling Unit) 연계를 통한 적용식물의 생육지표 분석)

  • Kim, Tae-Han;Lee, So-Dam;An, Byung-Ryul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.21 no.3
    • /
    • pp.99-110
    • /
    • 2018
  • Compared to yellow dust coming from China or particulate matter created naturally in spring due to Total Suspended Particulate(TSP), particulate matter in winter season have much more serious effect on human body as they penetrate cell membranes. Although such particulate matter are becoming a social issue, there are no concrete plans on how to reduce them. Air-purifying plants are limited in maintaining the indoor air quality of large area because it is usually difficult to quantify their performance. In order to improve this, a bio-filter that can be connected to air conditioner is suggested as an option. This study seeks to improve air conditioning model-based monitoring method for bio-filters from prior studies and objectify correlations between applied vegetation and growing environment into quantitative indicators. By doing so, this study seeks to provide criteria on plants applied to artificial soil-based vegetation bio-filters and basic information to set air-conditioning features. The study results confirmed significant tendency on the growing stability of each purifying plant in mechanical air-conditioning environment. Among three models selected for bio-filter vegetation models, epipremnum aureum showed high performance in quantitative indicators, including soil moisture, EC, and leaf temperature, etc., indicating that it would assure the highest growing stability in this test air-conditioning environment.

Case Studies of Mass Concentration Variation in the Central-Southern Korean Peninsula Caused by Synoptic Scale Transport of Dust Storms

  • Kim, Hak-Sung;Cho, Jae-Hee
    • Journal of the Korean earth science society
    • /
    • v.40 no.4
    • /
    • pp.414-427
    • /
    • 2019
  • In East Asia, the long-range transport of dust storms originating from Mongolia and northern China affects airborne dust loadings over downwind areas in the southern Korean Peninsula. Since 1997, dust loading cases caused by dust storms have been observed using the thresholds of total suspended particles (TSP, ${\geq}250{\mu}g\;m^{-3}\;hr^{-1}$) and particulate matter less than $10{\mu}g$ ($PM_{10}$, ${\geq}190{\mu}g\;m^{-3}\;hr^{-1}$) in the central-southern Korean Peninsula. There were two dust loading cases that exceeded these thresholds in 2016 and three in 2017, which reflects the downward trend of the last twenty-one years in the central-southern Korean Peninsula. Furthermore, five other dust loading cases with mass concentrations lower than the thresholds were observed from 2016 to 2017. In the moderate dust loading cases exceeding the thresholds, a descending motion of cut-off lows below $45^{\circ}N$ and a southward trough at 500 hPa gpm isopleths intensified at the western ridge, and largely extended the surface high-pressure system over southeast China. Airborne dust loadings following pronounced north-westerlies in the forward side of the high-pressure system were transported to the surface of the central-southern Korean Peninsula. However, in slight dust loading cases lower than the thresholds, the restricted descending motion of cut-off lows over $45^{\circ}N$ and the southwestward trough at 500 hPa gpm isopleths intensified the zonal flow over the Korean Peninsula. Surface high- and low-pressure systems moved eastward from the source compared to moderate dust loading cases. Due to the zonal movement of dust storms traversing eastern China, slight dust loading cases were observed with relatively higher ratios of $PM_{2.5}/TSP$ and carbon monoxide (CO) in the central-southern Korean Peninsula.

Monitoring of Working Environment Exposed to Particulate Matter in Greenhouse for Cultivating Flower and Fruit (과수 및 화훼 시설하우스 내 작업자의 미세먼지 노출현황 모니터링)

  • Seo, Hyo-Jae;Kim, Hyo-Cher;Seo, Il-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.31 no.2
    • /
    • pp.79-89
    • /
    • 2022
  • With the wide use of greenhouses, the working hours have been increasing inside the greenhouse for workers. In the closed ventilated greenhouse, the internal environment has less affected to external weather during making a suitable temperature for crop growth. Greenhouse workers are exposed to organic dust including soil dust, pollen, pesticide residues, microorganisms during tillage process, soil grading, fertilizing, and harvesting operations. Therefore, the health status and working environment exposed to workers should be considered inside the greenhouse. It is necessary to secure basic data on particulate matter (PM) concentrations in order to set up dust reduction and health safety plans. To understand the PM concentration of working environment in greenhouse, the PM concnentrations were monitored in the cut-rose and Hallabong greenhouses in terms of PM size, working type, and working period. Compare to no-work (move) period, a significant increase in PM concentration was found during tillage operation in Hallabong greenhouse by 4.94 times on TSP (total suspended particle), 2.71 times on PM-10 (particle size of 10 ㎛ or larger), and 1.53 times on PM-2.5, respectively. During pruning operation in cut-rose greenhouse, TSP concentration was 7.4 times higher and PM-10 concentration was 3.2 times higher than during no-work period. As a result of analysis of PM contribution ratio by particle sizes, it was shown that PM-10 constitute the largest percentage. There was a significant difference in the PM concentration between work and no-work periods, and the concentration of PM during work was significant higher (p < 0.001). It was found that workers were generally exposed to a high level of dust concentration from 2.5 ㎛ to 35.15 ㎛ during tillage operation.

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

Estimating PM Emission Factor from Coal-Fired Power Plants in Korea (화력발전소에서의 국내 배출계수 산정 방안 연구 -먼지를 중심으로-)

  • Jang, Kee-Won;Kim, Hyoung-Chun;Lee, Yong-Mi;Song, Deok-Jong;Jung, No-El;Kim, Sang-Kyun;Hong, Ji-Hyung;Lee, Suk-Jo;Han, Jong-Su
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.485-493
    • /
    • 2011
  • In Korea, PM (Particulate Matter) emissions caused by coal-fired power plants are measured by a system, so called Clean Air Policy Support System (CAPSS), which uses foreign emission factors. However, the system fails to reflect the characteristics of domestic power plants. In this regard, this study aims to develop local, accurate domestic emission factors. The study measured the amount of TSP (Total Suspended Particulates), PM10 and PM2.5 by collecting samples from the latter parts of pollution control devices which were installed at 3 bituminous-fired power plants and 3 anthracite-fired power plants. The results showed that the average concentrations of TSP, PM10 and PM2.5 measured at bituminous-fired power plants were 4.63 mg/$Sm^3$, 2.96 mg/$Sm^3$ and 3.07 mg/$Sm^3$ respectively, much higher than those from anthracite-fired power plants (2.96 mg/$Sm^3$, 2.47 mg/$Sm^3$ and 1.37 mg/$Sm^3$, respectively). In addition, bituminous-fired power plants showed higher ratios of PM10/TSP and PM2.5/TSP with 0.66 and 0.92, respectively, compared to 0.82 and 0.46, the ratios of PM10/TSP and PM2.5/TSP measured in anthracite-fired power plants. Emission factors based-on concentration measurements were also higher for bituminous-fired power plants, and PM with smaller particles tended to have bigger difference in emission factors between the two fuels. This study calculated the amount of PM emissions by using the estimated emission factors. When it comes to the PM emissions, it was less than that of CAPSS while similar to that of CleanSYS in its amount. It is expected that the emission factors developed by this study will be used in Korea replacing foreign emission factors currently used in Korea by ensuring the objectivity and reliability as domestic emission factors.